{"id":20937,"date":"2025-12-22T22:40:40","date_gmt":"2025-12-22T14:40:40","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=20937"},"modified":"2025-12-22T22:40:40","modified_gmt":"2025-12-22T14:40:40","slug":"vopv1000-2-2-dual-circuit-solar-combiner-box-2-in-2-out","status":"publish","type":"product","link":"https:\/\/test.viox.com\/cs\/produkt\/vopv1000-2-2-dual-circuit-solar-combiner-box-2-in-2-out\/","title":{"rendered":"Sol\u00e1rn\u00ed slu\u010dova\u010d VOPV1000-2\/2"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>P\u0159ehled produkt\u016f<\/h2>\n<p>VIOX Electric je p\u0159edn\u00ed v\u00fdrobce elektrick\u00fdch za\u0159\u00edzen\u00ed pro obnoviteln\u00e9 zdroje energie, specializuj\u00edc\u00ed se na vysoce kvalitn\u00ed sol\u00e1rn\u00ed fotovoltaick\u00e1 \u0159e\u0161en\u00ed pro glob\u00e1ln\u00ed trh. N\u00e1\u0161 sol\u00e1rn\u00ed slu\u010dova\u010d VOPV1000-2\/2 p\u0159edstavuje profesion\u00e1ln\u00ed dvouokruhov\u00e9 \u0159e\u0161en\u00ed navr\u017een\u00e9 speci\u00e1ln\u011b pro pokro\u010dil\u00e9 sol\u00e1rn\u00ed syst\u00e9my DC1000V vy\u017eaduj\u00edc\u00ed kompletn\u00ed nez\u00e1vislost okruh\u016f, schopnost du\u00e1ln\u00edho st\u0159\u00edda\u010de a optim\u00e1ln\u00ed provozn\u00ed flexibilitu.<\/p>\n<p>VOPV1000-2\/2 je profesion\u00e1ln\u00ed DC slu\u010dova\u010d navr\u017een\u00fd pro vysokonap\u011b\u0165ov\u00e9 sol\u00e1rn\u00ed FV syst\u00e9my pracuj\u00edc\u00ed p\u0159i DC1000V. Tato pokro\u010dil\u00e1 konfigurace se 2 vstupy a 2 v\u00fdstupy obsahuje <strong>dva zcela nez\u00e1visl\u00e9 okruhy<\/strong>, ka\u017ed\u00fd s vyhrazen\u00fdmi ochrann\u00fdmi a \u0159\u00eddic\u00edmi za\u0159\u00edzen\u00edmi. Na rozd\u00edl od kombinovan\u00fdch konfigurac\u00ed si architektura 2\/2 udr\u017euje \u00faplnou izolaci mezi stringy, tak\u017ee je ide\u00e1ln\u00ed pro syst\u00e9my s du\u00e1ln\u00edm st\u0159\u00edda\u010dem, aplikace s du\u00e1ln\u00edm MPPT, pole s v\u00fdchodo-z\u00e1padn\u00ed orientac\u00ed a projekty vy\u017eaduj\u00edc\u00ed maxim\u00e1ln\u00ed bezpe\u010dnost prost\u0159ednictv\u00edm nez\u00e1vislosti okruh\u016f.<\/p>\n<h2>Kl\u00ed\u010dov\u00e9 vlastnosti a v\u00fdhody<\/h2>\n<ul>\n<li><strong>Du\u00e1ln\u00ed nez\u00e1visl\u00e9 okruhy<\/strong>: Kompletn\u00ed elektrick\u00e1 izolace mezi dv\u011bma stringy \u2013 ka\u017ed\u00fd m\u00e1 vlastn\u00ed ochranu a v\u00fdstup<\/li>\n<li><strong>P\u0159ipraveno pro du\u00e1ln\u00ed st\u0159\u00edda\u010d<\/strong>: Ide\u00e1ln\u00ed pro syst\u00e9my se dv\u011bma samostatn\u00fdmi st\u0159\u00edda\u010di nebo st\u0159\u00edda\u010di s du\u00e1ln\u00edm MPPT vstupem<\/li>\n<li><strong>Maxim\u00e1ln\u00ed nez\u00e1vislost okruh\u016f<\/strong>: Ka\u017ed\u00fd string pracuje zcela nez\u00e1visle s vyhrazen\u00fdm sp\u00edna\u010dem, SPD a pojistkami<\/li>\n<li><strong>Jmenovit\u00e9 nap\u011bt\u00ed DC1000V<\/strong>: Optimalizov\u00e1no pro sol\u00e1rn\u00ed syst\u00e9my nov\u00e9 generace s vysoce \u00fa\u010dinn\u00fdmi moduly<\/li>\n<li><strong>Du\u00e1ln\u00ed ochrann\u00e9 syst\u00e9my<\/strong>: Dv\u011b kompletn\u00ed sady ochrany (2 sp\u00edna\u010de, 2 SPD, 4 pojistky) pro maxim\u00e1ln\u00ed bezpe\u010dnost<\/li>\n<li><strong>45A na v\u00fdstup<\/strong>: Ka\u017ed\u00fd ze dvou v\u00fdstup\u016f je dimenzov\u00e1n na 45A, co\u017e podporuje vysoce v\u00fdkonn\u00e9 stringy<\/li>\n<li><strong>Individu\u00e1ln\u00ed ovl\u00e1d\u00e1n\u00ed<\/strong>: Provozujte, udr\u017eujte nebo izolujte kter\u00fdkoli string, ani\u017e byste ovlivnili druh\u00fd<\/li>\n<li><strong>Zv\u00fd\u0161en\u00e1 bezpe\u010dnost<\/strong>: Kompletn\u00ed izolace okruh\u016f eliminuje zkraty mezi okruhy a zjednodu\u0161uje odstra\u0148ov\u00e1n\u00ed probl\u00e9m\u016f<\/li>\n<li><strong>Optimalizace v\u00fdchod-z\u00e1pad<\/strong>: Ide\u00e1ln\u00ed pro pole orientovan\u00e1 na v\u00fdchod-z\u00e1pad se samostatn\u00fdm sledov\u00e1n\u00edm MPPT<\/li>\n<li><strong>Kryt se st\u0159edn\u00ed kapacitou<\/strong>: VOAT-18 (380 x 230 x 120 mm) efektivn\u011b pojme dva pln\u00e9 ochrann\u00e9 obvody<\/li>\n<li><strong>Robustn\u00ed konstrukce<\/strong>: Kryt ABS s kryt\u00edm IP65 odol\u00e1v\u00e1 drsn\u00fdm podm\u00ednk\u00e1m prost\u0159ed\u00ed<\/li>\n<li><strong>N\u00e1kladov\u011b efektivn\u00ed nez\u00e1vislost<\/strong>: Architektura du\u00e1ln\u00edho okruhu za ni\u017e\u0161\u00ed cenu ne\u017e konfigurace 3\/3<\/li>\n<li><strong>Certifikovan\u00e1 kvalita<\/strong>: Spl\u0148uje normy EN50539 typu 2 pro vysokonap\u011b\u0165ov\u00e9 fotovoltaick\u00e9 aplikace<\/li>\n<\/ul>\n<h2>Technick\u00e9 specifikace<\/h2>\n<h3>Obecn\u00e9 \u00fadaje<\/h3>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<thead>\n<tr>\n<th>Parametr<\/th>\n<th>Specifikace<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>VOPV1000-2\/2<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00e9 nap\u011bt\u00ed<\/td>\n<td>DC1000V<\/td>\n<\/tr>\n<tr>\n<td>Konfigurace<\/td>\n<td>2 nez\u00e1visl\u00e9 vstupy \/ 2 nez\u00e1visl\u00e9 v\u00fdstupy<\/td>\n<\/tr>\n<tr>\n<td>Maxim\u00e1ln\u00ed proud na v\u00fdstup<\/td>\n<td>45A<\/td>\n<\/tr>\n<tr>\n<td>Maxim\u00e1ln\u00ed proud stringu<\/td>\n<td>15A na string<\/td>\n<\/tr>\n<tr>\n<td>Stupe\u0148 ochrany<\/td>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<td>Provozn\u00ed teplota<\/td>\n<td>-25\u00b0C a\u017e +60\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Maxim\u00e1ln\u00ed nadmo\u0159sk\u00e1 v\u00fd\u0161ka<\/td>\n<td>2000 m (standard), &gt;2000 m na vy\u017e\u00e1d\u00e1n\u00ed<\/td>\n<\/tr>\n<tr>\n<td>Dodr\u017eov\u00e1n\u00ed standard\u016f<\/td>\n<td>EN50539 Typ 2<\/td>\n<\/tr>\n<tr>\n<td>Izola\u010dn\u00ed nap\u011bt\u00ed<\/td>\n<td>DC1500V<\/td>\n<\/tr>\n<tr>\n<td>Nez\u00e1vislost okruh\u016f<\/td>\n<td>Kompletn\u00ed elektrick\u00e1 izolace mezi ob\u011bma okruhy<\/td>\n<\/tr>\n<tr>\n<td>Doporu\u010den\u00e1 velikost syst\u00e9mu<\/td>\n<td>10-15kW (du\u00e1ln\u00ed st\u0159\u00edda\u010d nebo du\u00e1ln\u00ed MPPT)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Specifikace krytu<\/h3>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<thead>\n<tr>\n<th>Parametr<\/th>\n<th>Hodnota<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>VOAT-18<\/td>\n<\/tr>\n<tr>\n<td>Materi\u00e1l<\/td>\n<td>ABS (Akrylonitrilbutadienstyren)<\/td>\n<\/tr>\n<tr>\n<td>Stupe\u0148 ochrany<\/td>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<td>Rozm\u011bry (V x \u0160 x H)<\/td>\n<td>380 mm x 230 mm x 120 mm<\/td>\n<\/tr>\n<tr>\n<td>Typ mont\u00e1\u017ee<\/td>\n<td>Mont\u00e1\u017e na st\u011bnu<\/td>\n<\/tr>\n<tr>\n<td>Barva<\/td>\n<td>Sv\u011btle \u0161ed\u00e1 (RAL 7035)<\/td>\n<\/tr>\n<tr>\n<td>Po\u017e\u00e1rn\u00ed odolnost<\/td>\n<td>Samozh\u00e1\u0161ec\u00ed, materi\u00e1l zpomaluj\u00edc\u00ed ho\u0159en\u00ed UL94 V0<\/td>\n<\/tr>\n<tr>\n<td>Odolnost proti UV z\u00e1\u0159en\u00ed<\/td>\n<td>UV stabilizov\u00e1no pro venkovn\u00ed pou\u017eit\u00ed<\/td>\n<\/tr>\n<tr>\n<td>Vstupn\u00ed body kabel\u016f<\/td>\n<td>Vylamovac\u00ed otvory M16\/M20\/M25 (uspo\u0159\u00e1dan\u00e9 pro 2 obvody)<\/td>\n<\/tr>\n<tr>\n<td>Hmotnost<\/td>\n<td>P\u0159ibli\u017en\u011b 4,5 kg (se v\u0161emi komponenty)<\/td>\n<\/tr>\n<tr>\n<td>Vnit\u0159n\u00ed uspo\u0159\u00e1d\u00e1n\u00ed<\/td>\n<td>Dv\u011b nez\u00e1visl\u00e9 sekce obvod\u016f s jasn\u00fdm odd\u011blen\u00edm a ozna\u010den\u00edm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Odpojova\u010d FV sp\u00edna\u010de<\/h3>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<thead>\n<tr>\n<th>Parametr<\/th>\n<th>Specifikace<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>VOD1-63\/4B<\/td>\n<\/tr>\n<tr>\n<td>Typ<\/td>\n<td>DC odp\u00edna\u010d z\u00e1t\u011b\u017ee<\/td>\n<\/tr>\n<tr>\n<td>Mno\u017estv\u00ed<\/td>\n<td>2 kusy (jeden na obvod)<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00e9 nap\u011bt\u00ed<\/td>\n<td>DC1000V<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00fd proud<\/td>\n<td>45 A na sp\u00edna\u010d<\/td>\n<\/tr>\n<tr>\n<td>Po\u010det sloup\u016f<\/td>\n<td>2-p\u00f3lov\u00fd (kladn\u00fd a z\u00e1porn\u00fd) na sp\u00edna\u010d<\/td>\n<\/tr>\n<tr>\n<td>P\u0159eru\u0161ovac\u00ed kapacita<\/td>\n<td>Podle EN50539<\/td>\n<\/tr>\n<tr>\n<td>Operace<\/td>\n<td>Ru\u010dn\u00ed oto\u010dn\u00fd provoz s jasnou indikac\u00ed ZAP\/VYP<\/td>\n<\/tr>\n<tr>\n<td>Mont\u00e1\u017e<\/td>\n<td>Kompatibiln\u00ed s DIN li\u0161tou (35 mm)<\/td>\n<\/tr>\n<tr>\n<td>Typ rukojeti<\/td>\n<td>\u010cerveno\/zelen\u00e1 oto\u010dn\u00e1 rukoje\u0165 s mo\u017enost\u00ed uzam\u010den\u00ed<\/td>\n<\/tr>\n<tr>\n<td>Kontaktn\u00ed materi\u00e1l<\/td>\n<td>Slitina st\u0159\u00edbra optimalizovan\u00e1 pro DC sp\u00edn\u00e1n\u00ed<\/td>\n<\/tr>\n<tr>\n<td>Nez\u00e1vislost<\/td>\n<td>Ka\u017ed\u00fd sp\u00edna\u010d ovl\u00e1d\u00e1 pouze sv\u016fj odpov\u00eddaj\u00edc\u00ed obvod<\/td>\n<\/tr>\n<tr>\n<td>Elektrick\u00e1 \u017eivotnost<\/td>\n<td>&gt;10 000 operac\u00ed p\u0159i jmenovit\u00e9m proudu<\/td>\n<\/tr>\n<tr>\n<td>Mechanick\u00e1 \u017eivotnost<\/td>\n<td>&gt;100 000 operac\u00ed<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>DC p\u0159ep\u011b\u0165ov\u00e1 ochrana (SPD)<\/h3>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<thead>\n<tr>\n<th>Parametr<\/th>\n<th>Specifikace<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>VO-PV1000<\/td>\n<\/tr>\n<tr>\n<td>Typ<\/td>\n<td>P\u0159ep\u011b\u0165ov\u00e9 ochrann\u00e9 za\u0159\u00edzen\u00ed DC typu 2<\/td>\n<\/tr>\n<tr>\n<td>Mno\u017estv\u00ed<\/td>\n<td>2 kusy (jeden na obvod)<\/td>\n<\/tr>\n<tr>\n<td>Maxim\u00e1ln\u00ed trval\u00e9 provozn\u00ed nap\u011bt\u00ed (Uc)<\/td>\n<td>DC1000V<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00fd vyb\u00edjec\u00ed proud (In)<\/td>\n<td>20 kA (8\/20 \u03bcs) na jednotku<\/td>\n<\/tr>\n<tr>\n<td>Maxim\u00e1ln\u00ed vyb\u00edjec\u00ed proud (Imax)<\/td>\n<td>40 kA (8\/20 \u03bcs) na jednotku<\/td>\n<\/tr>\n<tr>\n<td>\u00darove\u0148 ochrany nap\u011bt\u00ed (Up)<\/td>\n<td>\u22643,5 kV<\/td>\n<\/tr>\n<tr>\n<td>Po\u010det sloup\u016f<\/td>\n<td>2-p\u00f3lov\u00fd + PE na jednotku<\/td>\n<\/tr>\n<tr>\n<td>Doba odezvy<\/td>\n<td>&lt;25 ns<\/td>\n<\/tr>\n<tr>\n<td>Indikace stavu<\/td>\n<td>Vizu\u00e1ln\u00ed indika\u010dn\u00ed ok\u00e9nko (zelen\u00e1 = OK, \u010derven\u00e1 = vym\u011bnit)<\/td>\n<\/tr>\n<tr>\n<td>Standardn\u00ed<\/td>\n<td>EN50539 Typ 2, IEC 61643-31<\/td>\n<\/tr>\n<tr>\n<td>Mont\u00e1\u017e<\/td>\n<td>Kompatibiln\u00ed s DIN li\u0161tou<\/td>\n<\/tr>\n<tr>\n<td>Nez\u00e1vislost<\/td>\n<td>Ka\u017ed\u00e1 SPD chr\u00e1n\u00ed pouze sv\u016fj odpov\u00eddaj\u00edc\u00ed obvod<\/td>\n<\/tr>\n<tr>\n<td>Uhas\u00edn\u00e1n\u00ed n\u00e1sledn\u00e9ho proudu<\/td>\n<td>Samozh\u00e1\u0161ec\u00ed konstrukce<\/td>\n<\/tr>\n<tr>\n<td>Tepeln\u00fd odpojova\u010d<\/td>\n<td>Integrovan\u00fd pro ochranu na konci \u017eivotnosti<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>DC pojistkov\u00e9 pouzdro a pojistka<\/h3>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<thead>\n<tr>\n<th>Parametr<\/th>\n<th>Specifikace<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>VOPV-32<\/td>\n<\/tr>\n<tr>\n<td>Typ pojistky<\/td>\n<td>gPV (fotovoltaick\u00e1 pojistka)<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00e9 nap\u011bt\u00ed<\/td>\n<td>DC1000V<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00fd proud<\/td>\n<td>15A<\/td>\n<\/tr>\n<tr>\n<td>P\u0159eru\u0161ovac\u00ed kapacita<\/td>\n<td>30 kA @ DC1000V<\/td>\n<\/tr>\n<tr>\n<td>Velikost pojistky<\/td>\n<td>10 x 38 mm<\/td>\n<\/tr>\n<tr>\n<td>Konfigurace<\/td>\n<td>Celkem 4 pojistkov\u00e1 pouzdra (2 na string: kladn\u00fd a z\u00e1porn\u00fd)<\/td>\n<\/tr>\n<tr>\n<td>Pojistkov\u00e9 vlo\u017eky sou\u010d\u00e1st\u00ed balen\u00ed<\/td>\n<td>4 kusy (15A DC gPV pojistka)<\/td>\n<\/tr>\n<tr>\n<td>Sch\u00e9ma ochrany<\/td>\n<td>Individu\u00e1ln\u00ed dvoup\u00f3lov\u00e1 ochrana pro ka\u017ed\u00fd ze dvou string\u016f<\/td>\n<\/tr>\n<tr>\n<td>Mont\u00e1\u017e<\/td>\n<td>Kompatibiln\u00ed s DIN li\u0161tou<\/td>\n<\/tr>\n<tr>\n<td>Standardn\u00ed<\/td>\n<td>IEC 60269-6<\/td>\n<\/tr>\n<tr>\n<td>Indik\u00e1tor<\/td>\n<td>Vizu\u00e1ln\u00ed indik\u00e1tor stavu pojistky na pouzdro<\/td>\n<\/tr>\n<tr>\n<td>Kontaktn\u00ed materi\u00e1l<\/td>\n<td>M\u011b\u010f, poc\u00ednovan\u00e1<\/td>\n<\/tr>\n<tr>\n<td>Provozn\u00ed teplota<\/td>\n<td>-40 \u00b0C a\u017e +85 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Elektrick\u00e1 konfigurace<\/h2>\n<p>VOPV1000-2\/2 se vyzna\u010duje <strong>architekturou se dv\u011bma nez\u00e1visl\u00fdmi obvody<\/strong> kter\u00e1 udr\u017euje \u00fapln\u00e9 odd\u011blen\u00ed mezi stringy:<\/p>\n<h3>Dv\u011b nez\u00e1visl\u00e9 cesty obvodu:<\/h3>\n<p><strong>Obvod 1:<\/strong><\/p>\n<ul>\n<li>Vstup \u0159et\u011bzce 1 (kladn\u00fd + a z\u00e1porn\u00fd -)<\/li>\n<li>Dvoup\u00f3lov\u00e1 pojistkov\u00e1 ochrana (2 pojistky)<\/li>\n<li>P\u0159ep\u011b\u0165ov\u00e1 ochrana VO-PV1000<\/li>\n<li>Odpojova\u010d VOD1-63\/4B<\/li>\n<li>V\u00fdstup 1 (nez\u00e1visl\u00e9 nap\u00e1jen\u00ed do st\u0159\u00edda\u010de\/MPPT vstup 1)<\/li>\n<\/ul>\n<p><strong>Obvod 2:<\/strong><\/p>\n<ul>\n<li>Vstup \u0159et\u011bzce 2 (kladn\u00fd + a z\u00e1porn\u00fd -)<\/li>\n<li>Dvoup\u00f3lov\u00e1 pojistkov\u00e1 ochrana (2 pojistky)<\/li>\n<li>P\u0159ep\u011b\u0165ov\u00e1 ochrana VO-PV1000<\/li>\n<li>Odpojova\u010d VOD1-63\/4B<\/li>\n<li>V\u00fdstup 2 (nez\u00e1visl\u00e9 nap\u00e1jen\u00ed do st\u0159\u00edda\u010de\/MPPT vstup 2)<\/li>\n<\/ul>\n<h3>Kl\u00ed\u010dov\u00e9 architektonick\u00e9 prvky:<\/h3>\n<p><strong>Kompletn\u00ed izolace:<\/strong><\/p>\n<ul>\n<li>\u017d\u00e1dn\u00e9 elektrick\u00e9 spojen\u00ed mezi ob\u011bma obvody<\/li>\n<li>Ka\u017ed\u00fd obvod pracuje nez\u00e1visle<\/li>\n<li>Porucha v jednom obvodu neovlivn\u00ed druh\u00fd<\/li>\n<li>Zachov\u00e1ny individu\u00e1ln\u00ed nap\u011b\u0165ov\u00e9 a proudov\u00e9 charakteristiky<\/li>\n<\/ul>\n<p><strong>Nez\u00e1visl\u00e1 ochrana:<\/strong><\/p>\n<ul>\n<li>Ka\u017ed\u00fd \u0159et\u011bzec m\u00e1 vyhrazenou nadproudovou ochranu (pojistky)<\/li>\n<li>Ka\u017ed\u00fd obvod m\u00e1 vyhrazenou p\u0159ep\u011b\u0165ovou ochranu (SPD)<\/li>\n<li>Ka\u017ed\u00fd obvod m\u00e1 vyhrazen\u00fd odpojova\u010d<\/li>\n<li>Vizu\u00e1ln\u00ed monitorov\u00e1n\u00ed stavu pro ka\u017ed\u00e9 ochrann\u00e9 za\u0159\u00edzen\u00ed<\/li>\n<\/ul>\n<p><strong>Nez\u00e1visl\u00e9 ovl\u00e1d\u00e1n\u00ed:<\/strong><\/p>\n<ul>\n<li>Individu\u00e1ln\u00ed ovl\u00e1d\u00e1n\u00ed ON\/OFF pro ka\u017ed\u00fd obvod<\/li>\n<li>Nez\u00e1visl\u00e1 mo\u017enost uzam\u010den\u00ed\/ozna\u010den\u00ed (lockout\/tagout)<\/li>\n<li>Selektivn\u00ed \u00fadr\u017eba bez odstaven\u00ed syst\u00e9mu<\/li>\n<li>Zjednodu\u0161en\u00e9 uveden\u00ed do provozu a obsluha<\/li>\n<\/ul>\n<p><strong>Konfigurace termin\u00e1lu:<\/strong><\/p>\n<ul>\n<li>4 vstupn\u00ed svorky (2 na \u0159et\u011bzec: +\/-)<\/li>\n<li>4 v\u00fdstupn\u00ed svorky (2 na obvod: +\/-)<\/li>\n<li>1 spole\u010dn\u00e1 svorka PE (ochrann\u00e9 uzemn\u011bn\u00ed)<\/li>\n<li>V\u0161echny svorky dimenzov\u00e1ny na DC1000V<\/li>\n<li>Vstupn\u00ed svorky: kapacita kabelu 4-6mm\u00b2<\/li>\n<li>V\u00fdstupn\u00ed svorky: kapacita kabelu 6-16mm\u00b2<\/li>\n<\/ul>\n<h2>Kusovn\u00edk<\/h2>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<thead>\n<tr>\n<th>Polo\u017eka \u010d.<\/th>\n<th>Komponenta<\/th>\n<th>Model\/Specifikace<\/th>\n<th>Mno\u017estv\u00ed<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>ABS sk\u0159\u00ed\u0148<\/td>\n<td>VOAT-18, 380x230x120mm, IP65<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>DC odpojova\u010d<\/td>\n<td>VOD1-63\/4B, 2P, 45A, DC1000V<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>DC svodi\u010d p\u0159ep\u011bt\u00ed<\/td>\n<td>VO-PV1000, typ 2, 20kA, DC1000V<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>DC pojistkov\u00e9 pouzdro<\/td>\n<td>VOPV-32, 10x38mm, DC1000V<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>DC pojistkov\u00e1 vlo\u017eka (gPV)<\/td>\n<td>15A, DC1000V, 10x38mm, 30kA<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Vstupn\u00ed svorkovnice<\/td>\n<td>4-6mm\u00b2, \u010derven\u00e1\/\u010dern\u00e1, jmenovit\u00e9 nap\u011bt\u00ed 1000V<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>V\u00fdstupn\u00ed svorkovnice<\/td>\n<td>6-16mm\u00b2, \u010derven\u00e1\/\u010dern\u00e1, jmenovit\u00e9 nap\u011bt\u00ed 1000V<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>Svorkovnice PE<\/td>\n<td>6-16mm\u00b2, \u017elut\u00e1\/zelen\u00e1<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>Li\u0161ta DIN<\/td>\n<td>Standardn\u00ed 35mm, pozinkovan\u00e1<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>Kabelov\u00e9 v\u00fdvodky<\/td>\n<td>M16\/M20\/M25, kryt\u00ed IP65, 1000V<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>11<\/td>\n<td>Mont\u00e1\u017en\u00ed dr\u017e\u00e1ky<\/td>\n<td>Nerezov\u00e1 ocel 304<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>P\u0159ep\u00e1\u017eka pro odd\u011blen\u00ed obvod\u016f<\/td>\n<td>Nevodiv\u00e1 p\u0159ep\u00e1\u017eka<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>13<\/td>\n<td>\u0160t\u00edtky obvod\u016f<\/td>\n<td>Identifika\u010dn\u00ed \u0161t\u00edtky obvodu 1\/2<\/td>\n<td>1 sada<\/td>\n<\/tr>\n<tr>\n<td>14<\/td>\n<td>V\u00fdstra\u017en\u00e9 \u0161t\u00edtky<\/td>\n<td>Bezpe\u010dnostn\u00ed \u0161t\u00edtky DC1000V, v\u00edcejazy\u010dn\u00e9<\/td>\n<td>1 sada<\/td>\n<\/tr>\n<tr>\n<td>15<\/td>\n<td>Instala\u010dn\u00ed manu\u00e1l<\/td>\n<td>Anglicky\/v\u00edcejazy\u010dn\u011b, pr\u016fvodce konfigurac\u00ed 2\/2<\/td>\n<td>1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Aplikace<\/h2>\n<p>Sol\u00e1rn\u00ed slu\u010dova\u010d VOPV1000-2\/2 je speci\u00e1ln\u011b navr\u017een pro sol\u00e1rn\u00ed instalace se dv\u011bma obvody, kter\u00e9 vy\u017eaduj\u00ed \u00faplnou nez\u00e1vislost obvod\u016f:<\/p>\n<p><strong>Syst\u00e9my s du\u00e1ln\u00edm st\u0159\u00edda\u010dem<\/strong><\/p>\n<ul>\n<li>Syst\u00e9my se dv\u011bma samostatn\u00fdmi \u0159et\u011bzcov\u00fdmi st\u0159\u00edda\u010di<\/li>\n<li>Architektury s distribuovan\u00fdmi st\u0159\u00edda\u010di<\/li>\n<li>Dva nez\u00e1visl\u00e9 nap\u00e1jec\u00ed zdroje pro redundanci<\/li>\n<li>R\u016fzn\u00e9 typy nebo zna\u010dky st\u0159\u00edda\u010d\u016f pro ka\u017ed\u00fd okruh<\/li>\n<li>Syst\u00e9my vy\u017eaduj\u00edc\u00ed izolaci na \u00farovni st\u0159\u00edda\u010de pro \u00fadr\u017ebu<\/li>\n<\/ul>\n<p><strong>Aplikace se st\u0159\u00edda\u010di s du\u00e1ln\u00edm MPPT<\/strong><\/p>\n<ul>\n<li>St\u0159\u00edda\u010de se dv\u011bma MPPT vstupy (ka\u017ed\u00fd okruh na samostatn\u00fd MPPT)<\/li>\n<li>Optimalizovan\u00fd zisk energie ze dvou r\u016fzn\u00fdch orientac\u00ed<\/li>\n<li>Nez\u00e1visl\u00e9 sledov\u00e1n\u00ed bodu maxim\u00e1ln\u00edho v\u00fdkonu pro ka\u017ed\u00fd string<\/li>\n<li>Vysoce v\u00fdkonn\u00e9 st\u0159\u00edda\u010de vy\u017eaduj\u00edc\u00ed izolovan\u00e9 DC vstupy<\/li>\n<li>Hybridn\u00ed st\u0159\u00edda\u010de se dv\u011bma DC vstupy<\/li>\n<\/ul>\n<p><strong>Syst\u00e9my s orientac\u00ed na v\u00fdchod-z\u00e1pad<\/strong><\/p>\n<ul>\n<li>Pole orientovan\u00e9 na v\u00fdchod na okruhu 1, na z\u00e1pad na okruhu 2<\/li>\n<li>Optimalizace roz\u0161\u00ed\u0159en\u00e9ho denn\u00edho profilu v\u00fdroby<\/li>\n<li>Vyv\u00e1\u017een\u00ed v\u00fdroby energie r\u00e1no a ve\u010der<\/li>\n<li>Sn\u00ed\u017een\u00ed poledn\u00edch v\u00fdkonov\u00fdch \u0161pi\u010dek<\/li>\n<li>Optim\u00e1ln\u00ed pro sol\u00e1rn\u00ed syst\u00e9my \u0161etrn\u00e9 k s\u00edti<\/li>\n<\/ul>\n<p><strong>Pole s v\u00edce orientacemi<\/strong><\/p>\n<ul>\n<li>Dv\u011b r\u016fzn\u00e9 \u010d\u00e1sti st\u0159echy s odli\u0161n\u00fdmi charakteristikami<\/li>\n<li>R\u016fzn\u00e9 \u00fahly sklonu vy\u017eaduj\u00edc\u00ed samostatnou optimalizaci<\/li>\n<li>Pole s r\u016fzn\u00fdmi vzory st\u00edn\u011bn\u00ed<\/li>\n<li>Rozd\u011blen\u00ed sever-jih pro aplikace na ji\u017en\u00ed polokouli<\/li>\n<li>Optim\u00e1ln\u00ed zisk energie z r\u016fznorod\u00fdch podm\u00ednek<\/li>\n<\/ul>\n<p><strong>Reziden\u010dn\u00ed a komer\u010dn\u00ed instalace<\/strong><\/p>\n<ul>\n<li>St\u0159edn\u011b velk\u00e9 reziden\u010dn\u00ed syst\u00e9my (10-15kW) s mo\u017enost\u00ed du\u00e1ln\u00ed orientace<\/li>\n<li>Komer\u010dn\u00ed st\u0159e\u0161n\u00ed pole vy\u017eaduj\u00edc\u00ed maxim\u00e1ln\u00ed flexibilitu<\/li>\n<li>Fotovoltaika integrovan\u00e1 do budovy (BIPV) se dv\u011bma z\u00f3nami<\/li>\n<li>Pr\u016fmyslov\u00e9 provozy s rozd\u011blenou sol\u00e1rn\u00ed v\u00fdrobou<\/li>\n<li>Budovy s v\u00edce n\u00e1jemn\u00edky se samostatn\u00fdm m\u011b\u0159en\u00edm pro ka\u017ed\u00fd okruh<\/li>\n<\/ul>\n<p><strong>Projekty s f\u00e1zovanou instalac\u00ed<\/strong><\/p>\n<ul>\n<li><strong>F\u00e1ze 1<\/strong>: Instalace okruhu 1, provoz nez\u00e1visle<\/li>\n<li><strong>F\u00e1ze 2<\/strong>: P\u0159id\u00e1n\u00ed okruhu 2 bez ovlivn\u011bn\u00ed okruhu 1<\/li>\n<li><strong>Flexibilita<\/strong>: Ka\u017ed\u00e1 f\u00e1ze funguje nez\u00e1visle b\u011bhem cel\u00e9ho procesu<\/li>\n<li><strong>Ochrana investic<\/strong>: Za\u010dn\u011bte v mal\u00e9m, roz\u0161i\u0159te, a\u017e to rozpo\u010det dovol\u00ed<\/li>\n<\/ul>\n<p><strong>Aplikace s vysokou spolehlivost\u00ed<\/strong><\/p>\n<ul>\n<li>Syst\u00e9my vy\u017eaduj\u00edc\u00ed izolaci poruch<\/li>\n<li>Kritick\u00e1 infrastruktura s po\u017eadavky na redundanci<\/li>\n<li>Aplikace vy\u017eaduj\u00edc\u00ed individu\u00e1ln\u00ed \u0159\u00edzen\u00ed okruh\u016f<\/li>\n<li>Projekty vy\u017eaduj\u00edc\u00ed komplexn\u00ed bezpe\u010dnostn\u00ed dokumentaci<\/li>\n<li>Instalace s p\u0159\u00edsn\u00fdmi po\u017eadavky na shodu<\/li>\n<\/ul>\n<p><strong>Konfigurace s rozd\u011blen\u00fdm polem<\/strong><\/p>\n<ul>\n<li>R\u016fzn\u00e9 typy modul\u016f pro ka\u017ed\u00fd okruh (testov\u00e1n\u00ed nebo migrace)<\/li>\n<li>Sm\u00ed\u0161en\u00e9 d\u00e9lky string\u016f nebo po\u010dty modul\u016f<\/li>\n<li>Samostatn\u00e9 monitorov\u00e1n\u00ed pro ka\u017edou orientaci<\/li>\n<li>Nez\u00e1visl\u00e1 anal\u00fdza v\u00fdkonu<\/li>\n<li>Flexibiln\u00ed pro budouc\u00ed \u00fapravy<\/li>\n<\/ul>\n<h2>V\u00fdhody konfigurace 2\/2 s nez\u00e1visl\u00fdm zapojen\u00edm<\/h2>\n<h3>Kompletn\u00ed nez\u00e1vislost okruh\u016f<\/h3>\n<p><strong>Tot\u00e1ln\u00ed elektrick\u00e1 izolace<\/strong><\/p>\n<ul>\n<li>Nulov\u00e9 elektrick\u00e9 spojen\u00ed mezi ob\u011bma okruhy<\/li>\n<li>Porucha v jednom okruhu se nem\u016f\u017ee \u0161\u00ed\u0159it do druh\u00e9ho<\/li>\n<li>Maxim\u00e1ln\u00ed spolehlivost syst\u00e9mu d\u00edky redundanci<\/li>\n<li>Zjednodu\u0161en\u00e1 diagnostika a odstra\u0148ov\u00e1n\u00ed poruch<\/li>\n<li>Zv\u00fd\u0161en\u00e1 bezpe\u010dnost d\u00edky izolaci<\/li>\n<\/ul>\n<p><strong>Individu\u00e1ln\u00ed \u0159\u00edzen\u00ed okruh\u016f<\/strong><\/p>\n<ul>\n<li>Provoz kter\u00e9hokoli okruhu nez\u00e1visle<\/li>\n<li>\u00dadr\u017eba na jednom okruhu bez odstaven\u00ed syst\u00e9mu<\/li>\n<li>Selektivn\u00ed aktivace pro uveden\u00ed do provozu<\/li>\n<li>Nez\u00e1visl\u00e9 testov\u00e1n\u00ed a validace<\/li>\n<li>Flexibiln\u00ed provozn\u00ed re\u017eimy<\/li>\n<\/ul>\n<h3>V\u00fdhody syst\u00e9mu se dv\u011bma st\u0159\u00edda\u010di<\/h3>\n<p><strong>Ide\u00e1ln\u00ed pro dva st\u0159\u00edda\u010de<\/strong><\/p>\n<ul>\n<li>P\u0159\u00edm\u00e9 p\u0159ipojen\u00ed ke dv\u011bma samostatn\u00fdm st\u0159\u00edda\u010d\u016fm<\/li>\n<li>Podporovan\u00e9 distribuovan\u00e9 architektury st\u0159\u00edda\u010d\u016f<\/li>\n<li>Optim\u00e1ln\u00ed dimenzov\u00e1n\u00ed st\u0159\u00edda\u010de pro ka\u017ed\u00fd obvod<\/li>\n<li>Redundance na \u00farovni st\u0159\u00edda\u010de<\/li>\n<li>Individu\u00e1ln\u00ed \u00fadr\u017eba st\u0159\u00edda\u010de bez odst\u00e1vky syst\u00e9mu<\/li>\n<\/ul>\n<p><strong>Optimalizace Dual-MPPT<\/strong><\/p>\n<ul>\n<li>Ka\u017ed\u00fd obvod m\u00e1 samostatn\u00fd MPPT vstup pro maxim\u00e1ln\u00ed \u00fa\u010dinnost<\/li>\n<li>Nez\u00e1visl\u00e1 optimalizace pro ka\u017edou orientaci stringu<\/li>\n<li>Lep\u0161\u00ed v\u00fdkon p\u0159i r\u016fzn\u00e9m slune\u010dn\u00edm z\u00e1\u0159en\u00ed<\/li>\n<li>Maximalizovan\u00fd zisk energie z du\u00e1ln\u00edch orientac\u00ed<\/li>\n<li>Pokro\u010dil\u00e1 integrace v\u00fdkonov\u00e9 elektroniky<\/li>\n<\/ul>\n<h3>Vynikaj\u00edc\u00ed syst\u00e9m V\u00fdchod-Z\u00e1pad<\/h3>\n<p><strong>Optim\u00e1ln\u00ed pro pole V\u00fdchod-Z\u00e1pad<\/strong><\/p>\n<ul>\n<li>Rann\u00ed v\u00fdkon z v\u00fdchodn\u00edho pole (Obvod 1)<\/li>\n<li>Ve\u010dern\u00ed v\u00fdkon ze z\u00e1padn\u00edho pole (Obvod 2)<\/li>\n<li>Roz\u0161\u00ed\u0159en\u00fd denn\u00ed profil v\u00fdroby<\/li>\n<li>Sn\u00ed\u017een\u00e9 zat\u00ed\u017een\u00ed s\u00edt\u011b v poledne<\/li>\n<li>V\u00fdkonov\u00e1 distribuce \u0161etrn\u00e1 k s\u00edti<\/li>\n<\/ul>\n<p><strong>V\u00fdhody v\u00fdkonu<\/strong><\/p>\n<ul>\n<li>Lep\u0161\u00ed ro\u010dn\u00ed v\u00fdnos energie ne\u017e syst\u00e9my orientovan\u00e9 pouze na jih v mnoha lokalit\u00e1ch<\/li>\n<li>Sn\u00ed\u017een\u00e9 omezen\u00ed v\u00fdkonu ve vysoce slune\u010dn\u00edch oblastech<\/li>\n<li>Hodnotn\u011bj\u0161\u00ed v\u00fdroba energie b\u011bhem \u0161pi\u010dkov\u00fdch hodin<\/li>\n<li>Provoz s ni\u017e\u0161\u00ed teplotou (panely nikdy nejsou vystaveny p\u0159\u00edm\u00e9mu poledn\u00edmu slunci)<\/li>\n<li>Sn\u00ed\u017een\u00e9 po\u017eadavky na p\u0159edimenzov\u00e1n\u00ed st\u0159\u00edda\u010de<\/li>\n<\/ul>\n<h3>Zv\u00fd\u0161en\u00e1 bezpe\u010dnost a spolehlivost<\/h3>\n<p><strong>Maxim\u00e1ln\u00ed izolace poruch<\/strong><\/p>\n<ul>\n<li>Porucha v jednom stringu neovlivn\u00ed druh\u00fd<\/li>\n<li>Pokra\u010dov\u00e1n\u00ed v provozu na 50% kapacity, pokud jeden obvod sel\u017ee<\/li>\n<li>Sn\u00ed\u017een\u00e9 riziko kask\u00e1dov\u00fdch selh\u00e1n\u00ed<\/li>\n<li>Vylep\u0161en\u00e9 omezen\u00ed obloukov\u00e9ho zkratu<\/li>\n<li>Zjednodu\u0161en\u00e9 odstra\u0148ov\u00e1n\u00ed probl\u00e9m\u016f s izolovan\u00fdmi obvody<\/li>\n<\/ul>\n<p><strong>Du\u00e1ln\u00ed ochrann\u00e9 syst\u00e9my<\/strong><\/p>\n<ul>\n<li>Dv\u011b kompletn\u00ed sady ochrany eliminuj\u00ed jednotliv\u00e9 body selh\u00e1n\u00ed<\/li>\n<li>Nez\u00e1visl\u00e1 p\u0159ep\u011b\u0165ov\u00e1 ochrana pro ka\u017ed\u00fd obvod<\/li>\n<li>Vyhrazen\u00e9 sp\u00edn\u00e1n\u00ed pro ka\u017ed\u00fd obvod pro bezpe\u010dnost \u00fadr\u017eby<\/li>\n<li>Individu\u00e1ln\u00ed ji\u0161t\u011bn\u00ed zabra\u0148uje probl\u00e9m\u016fm mezi obvody<\/li>\n<li>Redundantn\u00ed filozofie ochrany<\/li>\n<\/ul>\n<h3>Provozn\u00ed flexibilita<\/h3>\n<p><strong>Zjednodu\u0161en\u00e1 \u00fadr\u017eba<\/strong><\/p>\n<ul>\n<li>Servis jednoho obvodu, zat\u00edmco druh\u00fd z\u016fst\u00e1v\u00e1 v provozu<\/li>\n<li>Minimalizace prostoj\u016f syst\u00e9mu<\/li>\n<li>Pl\u00e1novan\u00e1 \u00fadr\u017eba bez ztr\u00e1ty produkce<\/li>\n<li>Individu\u00e1ln\u00ed v\u00fdm\u011bna komponent<\/li>\n<li>Zjednodu\u0161en\u00e9 postupy lockout\/tagout<\/li>\n<\/ul>\n<p><strong>F\u00e1zovan\u00e9 uv\u00e1d\u011bn\u00ed do provozu<\/strong><\/p>\n<ul>\n<li>Aktivace obvod\u016f jeden po druh\u00e9m b\u011bhem uv\u00e1d\u011bn\u00ed do provozu<\/li>\n<li>Testov\u00e1n\u00ed ka\u017ed\u00e9ho obvodu nez\u00e1visle<\/li>\n<li>Zjednodu\u0161en\u00e9 postupy spou\u0161t\u011bn\u00ed<\/li>\n<li>Sn\u00ed\u017een\u00e9 riziko uv\u00e1d\u011bn\u00ed do provozu<\/li>\n<li>Systematick\u00fd proces validace<\/li>\n<\/ul>\n<p><strong>Sm\u00ed\u0161en\u00e9 konfigurace syst\u00e9mu<\/strong><\/p>\n<ul>\n<li>R\u016fzn\u00e9 konfigurace string\u016f pro ka\u017ed\u00fd obvod jsou mo\u017en\u00e9<\/li>\n<li>R\u016fzn\u00e9 typy nebo mno\u017estv\u00ed modul\u016f pro ka\u017ed\u00fd obvod<\/li>\n<li>P\u0159izp\u016fsoben\u00ed se zm\u011bn\u00e1m syst\u00e9mu v pr\u016fb\u011bhu \u010dasu<\/li>\n<li>Flexibiln\u00ed pro budouc\u00ed \u00fapravy<\/li>\n<li>Podpora star\u0161\u00edch i nov\u00fdch komponent sou\u010dasn\u011b<\/li>\n<\/ul>\n<h3>Anal\u00fdza n\u00e1klad\u016f a p\u0159\u00ednos\u016f<\/h3>\n<p><strong>Optim\u00e1ln\u00ed pom\u011br n\u00e1klad\u016f a v\u00fdkonu<\/strong><\/p>\n<ul>\n<li>Ekonomi\u010dt\u011bj\u0161\u00ed ne\u017e konfigurace 3\/3 pro pot\u0159eby dvou string\u016f<\/li>\n<li>Vy\u0161\u0161\u00ed hodnota ne\u017e 1\/1 d\u00edky du\u00e1ln\u00ed obvodov\u00e9 kapacit\u011b<\/li>\n<li>Ni\u017e\u0161\u00ed instala\u010dn\u00ed n\u00e1klady ne\u017e samostatn\u00e9 slu\u010dovac\u00ed boxy<\/li>\n<li>Sn\u00ed\u017een\u00e1 slo\u017eitost kabel\u00e1\u017ee ke st\u0159\u00edda\u010di (st\u0159\u00edda\u010d\u016fm)<\/li>\n<li>Jednoduch\u00e9 pouzdro zjednodu\u0161uje instalaci<\/li>\n<\/ul>\n<p><strong>Dlouhodob\u00e1 hodnota<\/strong><\/p>\n<ul>\n<li>Lep\u0161\u00ed v\u00fdnos energie d\u00edky optimalizaci orientace<\/li>\n<li>Vy\u0161\u0161\u00ed spolehlivost sni\u017euje celkov\u00e9 n\u00e1klady na vlastnictv\u00ed<\/li>\n<li>Minim\u00e1ln\u00ed prostoje \u00fadr\u017eby chr\u00e1n\u00ed p\u0159\u00edjmy<\/li>\n<li>Ochrana investic prost\u0159ednictv\u00edm flexibility<\/li>\n<li>Prodlou\u017een\u00e1 \u017eivotnost syst\u00e9mu d\u00edky redundanci<\/li>\n<\/ul>\n<h2>Kvalita a shoda<\/h2>\n<p><strong>Certifikace a normy:<\/strong><\/p>\n<ul>\n<li>EN50539 Typ 2 \u2013 Fotovoltaick\u00e9 (PV) syst\u00e9my \u2013 DC konektory pro aplikace 1000V<\/li>\n<li>IEC 60269-6 \u2013 N\u00edzkonap\u011b\u0165ov\u00e9 pojistky pro fotovoltaick\u00e9 aplikace (1000V)<\/li>\n<li>IEC 61643-31 \u2013 P\u0159ep\u011b\u0165ov\u00e9 ochrany pro fotovoltaick\u00e9 instalace (1000V)<\/li>\n<li>IEC 60947-3 \u2013 Sp\u00ednac\u00ed a \u0159\u00eddic\u00ed p\u0159\u00edstroje nn \u2013 Sp\u00edna\u010de, odp\u00edna\u010de (1000V DC)<\/li>\n<li>IP65 \u2013 Stupe\u0148 kryt\u00ed (prachot\u011bsn\u00e9 a chr\u00e1n\u011bn\u00e9 proti tryskaj\u00edc\u00ed vod\u011b)<\/li>\n<li>Vyhovuje RoHS \u2013 Omezen\u00ed pou\u017e\u00edv\u00e1n\u00ed nebezpe\u010dn\u00fdch l\u00e1tek<\/li>\n<li>Vyhovuje REACH \u2013 Na\u0159\u00edzen\u00ed EU o chemick\u00fdch l\u00e1tk\u00e1ch<\/li>\n<li>Ozna\u010den\u00ed CE \u2013 Evropsk\u00e1 shoda<\/li>\n<\/ul>\n<p><strong>Testov\u00e1n\u00ed zaji\u0161t\u011bn\u00ed kvality:<\/strong><\/p>\n<ul>\n<li>Tov\u00e1rn\u00ed testov\u00e1n\u00ed 100% obou nez\u00e1visl\u00fdch obvod\u016f<\/li>\n<li>Zkou\u0161ka v\u00fddr\u017enosti vysok\u00e9ho nap\u011bt\u00ed (DC1500V po dobu 1 minuty na obvod)<\/li>\n<li>Ov\u011b\u0159en\u00ed izola\u010dn\u00edho odporu (&gt;200M\u03a9 @ DC1000V na obvod)<\/li>\n<li>Zkou\u0161ka izolace obvod\u016f (&gt;200M\u03a9 mezi obvody)<\/li>\n<li>Zkou\u0161ky st\u00e1rnut\u00ed p\u0159i vysok\u00e9 teplot\u011b (96 hodin p\u0159i 70 \u00b0C)<\/li>\n<li>Zkou\u0161ky teplotn\u00edmi cykly (-40 \u00b0C a\u017e +85 \u00b0C, 100 cykl\u016f)<\/li>\n<li>Zkou\u0161ka mechanick\u00e9ho nam\u00e1h\u00e1n\u00ed (vibrace a n\u00e1raz podle norem IEC)<\/li>\n<li>M\u011b\u0159en\u00ed p\u0159echodov\u00e9ho odporu na v\u0161ech svork\u00e1ch (&lt;30\u03bc\u03a9)<\/li>\n<li>Ob\u011b p\u0159ep\u011b\u0165ov\u00e9 ochrany testov\u00e1ny podle IEC 61643-31<\/li>\n<li>Zkou\u0161ka UV st\u00e1rnut\u00ed materi\u00e1l\u016f krytu (1000 hodin)<\/li>\n<li>Ov\u011b\u0159en\u00ed nez\u00e1visl\u00e9ho provozu pro oba obvody<\/li>\n<\/ul>\n<p><strong>Excelentn\u00ed v\u00fdroba:<\/strong><\/p>\n<ul>\n<li>V\u00fdrobn\u00ed z\u00e1vod s certifikac\u00ed ISO 9001:2015<\/li>\n<li>Syst\u00e9m environment\u00e1ln\u00edho managementu ISO 14001:2015<\/li>\n<li>P\u0159\u00edsn\u00e9 postupy kontroly kvality pro sestavy s du\u00e1ln\u00edm obvodem<\/li>\n<li>V\u00fdb\u011br pr\u00e9miov\u00fdch komponent od certifikovan\u00fdch dodavatel\u016f (UL, T\u00dcV)<\/li>\n<li>Specializovan\u00fd mont\u00e1\u017en\u00ed proces pro architekturu nez\u00e1visl\u00fdch obvod\u016f<\/li>\n<li>Ru\u010dn\u00ed kontrola v\u0161ech elektrick\u00fdch spoj\u016f a izola\u010dn\u00edch bari\u00e9r<\/li>\n<li>Komplexn\u00ed fin\u00e1ln\u00ed kontrola a funk\u010dn\u00ed testov\u00e1n\u00ed na obvod<\/li>\n<li>Kompletn\u00ed syst\u00e9m sledovatelnosti pro v\u0161echny komponenty a sestavy<\/li>\n<li>Programy neust\u00e1l\u00e9ho zlep\u0161ov\u00e1n\u00ed zalo\u017een\u00e9 na datech o provozu v ter\u00e9nu<\/li>\n<\/ul>\n<h2>Instalace a \u00fadr\u017eba<\/h2>\n<h3>Pokyny pro instalaci:<\/h3>\n<p><strong>V\u00fdb\u011br m\u00edsta pro instalaci s du\u00e1ln\u00edm obvodem:<\/strong><\/p>\n<ul>\n<li>Mont\u00e1\u017e na dob\u0159e v\u011btran\u00e9m m\u00edst\u011b se snadn\u00fdm p\u0159\u00edstupem pro \u00fadr\u017ebu<\/li>\n<li>Zajist\u011bte ochranu p\u0159ed p\u0159\u00edm\u00fdm slune\u010dn\u00edm z\u00e1\u0159en\u00edm, de\u0161t\u011bm a hromad\u011bn\u00edm vody<\/li>\n<li>Minim\u00e1ln\u00ed vzd\u00e1lenost 150 mm na v\u0161ech stran\u00e1ch pro ventilaci a p\u0159\u00edstup<\/li>\n<li>Zva\u017ete cesty pro vstup kabel\u016f ze dvou r\u016fzn\u00fdch m\u00edst \u0159et\u011bzc\u016f<\/li>\n<li>Um\u00edst\u011bte pro snadnou vizu\u00e1ln\u00ed kontrolu obou indik\u00e1tor\u016f SPD<\/li>\n<li>Zajist\u011bte dostate\u010dn\u00fd prostor pro budouc\u00ed servisn\u00ed p\u0159\u00edstup k jednotliv\u00fdm obvod\u016fm<\/li>\n<\/ul>\n<p><strong>Postup mont\u00e1\u017ee:<\/strong><\/p>\n<ul>\n<li>Pou\u017eijte vhodn\u00fd mont\u00e1\u017en\u00ed materi\u00e1l dimenzovan\u00fd na hmotnost krytu (4,5 kg + kabely)<\/li>\n<li>Zajist\u011bte vodorovnou instalaci pomoc\u00ed vodov\u00e1hy<\/li>\n<li>Ov\u011b\u0159te, zda je kryt bezpe\u010dn\u011b upevn\u011bn (minim\u00e1ln\u011b 4 upev\u0148ovac\u00ed body)<\/li>\n<li>Po instalaci zachovejte stupe\u0148 kryt\u00ed IP65<\/li>\n<li>Zva\u017ete rozlo\u017een\u00ed zat\u00ed\u017een\u00ed na mont\u00e1\u017en\u00ed povrch<\/li>\n<\/ul>\n<p><strong>Po\u0159ad\u00ed p\u0159ipojen\u00ed obvod\u016f:<\/strong><\/p>\n<ul>\n<li>P\u0159ed p\u0159ipojen\u00edm jasn\u011b ozna\u010dte oba obvody (Obvod 1, Obvod 2)<\/li>\n<li>Pro systematickou instalaci p\u0159ipojte obvody v \u010d\u00edseln\u00e9m po\u0159ad\u00ed<\/li>\n<li><strong>Kritick\u00fd<\/strong>: B\u011bhem zapojov\u00e1n\u00ed udr\u017eujte \u00fapln\u00e9 odd\u011blen\u00ed mezi obvody<\/li>\n<li>P\u0159ed ukon\u010den\u00edm ov\u011b\u0159te spr\u00e1vnou polaritu pro ka\u017ed\u00fd obvod<\/li>\n<li>Pou\u017eijte kabely dimenzovan\u00e9 na DC1000V s odpov\u00eddaj\u00edc\u00ed teplotn\u00ed odolnost\u00ed<\/li>\n<li>Vstupn\u00ed kabely: 4-6mm\u00b2 (max. 15A na \u0159et\u011bzec)<\/li>\n<li>V\u00fdstupn\u00ed kabely: 6-16mm\u00b2 (pro kapacitu 45A)<\/li>\n<\/ul>\n<p><strong>Nez\u00e1visl\u00e9 zapojen\u00ed obvod\u016f:<\/strong><\/p>\n<ul>\n<li>Ve\u010fte kabely obvodu 1 a obvodu 2 odd\u011blen\u011b, abyste p\u0159ede\u0161li z\u00e1m\u011bn\u011b<\/li>\n<li>Pou\u017eijte konzistentn\u00ed barevn\u00e9 k\u00f3dov\u00e1n\u00ed v r\u00e1mci ka\u017ed\u00e9ho obvodu (\u010derven\u00e1 +, \u010dern\u00e1 -)<\/li>\n<li>Pokud je to mo\u017en\u00e9, udr\u017eujte fyzick\u00e9 odd\u011blen\u00ed mezi kabely obvod\u016f<\/li>\n<li>Jasn\u011b ozna\u010dte v\u0161echny kabely \u010d\u00edslem obvodu<\/li>\n<li>Pou\u017eijte spr\u00e1vn\u00fd utahovac\u00ed moment na v\u0161echny svorky (1,2-1,5 Nm podle specifikace)<\/li>\n<li>Zajist\u011bte spr\u00e1vn\u00e9 ut\u011bsn\u011bn\u00ed vstupu kabel\u016f pomoc\u00ed vhodn\u00fdch v\u00fdvodek<\/li>\n<\/ul>\n<p><strong>Kontroly p\u0159ed uveden\u00edm do provozu:<\/strong><\/p>\n<ul>\n<li>Prove\u010fte zkou\u0161ku izola\u010dn\u00edho odporu na ka\u017ed\u00e9m obvodu (minim\u00e1ln\u011b 200M\u03a9 @ DC1000V)<\/li>\n<li>Ov\u011b\u0159te izolaci mezi obvody (minim\u00e1ln\u011b 200M\u03a9 mezi obvody)<\/li>\n<li>Ov\u011b\u0159te kontinuitu PE p\u0159ipojen\u00ed (spole\u010dn\u00e9 pro oba obvody)<\/li>\n<li>Zkontrolujte dota\u017een\u00ed v\u0161ech mechanick\u00fdch spoj\u016f v ka\u017ed\u00e9m obvodu<\/li>\n<li>Potvr\u010fte, \u017ee oba indik\u00e1tory SPD sv\u00edt\u00ed zelen\u011b (provozn\u00ed stav)<\/li>\n<li>Otestujte funkci ka\u017ed\u00e9ho sp\u00ednac\u00edho odp\u00edna\u010de jednotliv\u011b bez z\u00e1t\u011b\u017ee<\/li>\n<li>Ov\u011b\u0159te, zda jsou v\u0161echny kabelov\u00e9 v\u00fdvodky spr\u00e1vn\u011b ut\u011bsn\u011bny<\/li>\n<li>Zm\u011b\u0159te nap\u011bt\u00ed napr\u00e1zdno ka\u017ed\u00e9ho \u0159et\u011bzce nez\u00e1visle<\/li>\n<li><strong>Kritick\u00fd<\/strong>: Ov\u011b\u0159te, zda neexistuje \u017e\u00e1dn\u00e9 elektrick\u00e9 spojen\u00ed mezi obvody<\/li>\n<\/ul>\n<h3>Bezpe\u010dnostn\u00ed opat\u0159en\u00ed:<\/h3>\n<p><strong>Bezpe\u010dnostn\u00ed aspekty dvouokruhov\u00e9ho syst\u00e9mu:<\/strong><\/p>\n<ul>\n<li><strong>Kritick\u00fd<\/strong>: I p\u0159i odpojen\u00ed jednoho obvodu z\u016fst\u00e1v\u00e1 druh\u00fd obvod pod nap\u011bt\u00edm<\/li>\n<li>Nikdy nep\u0159edpokl\u00e1dejte, \u017ee je cel\u00fd syst\u00e9m bez nap\u011bt\u00ed, dokud nejsou oba obvody ov\u011b\u0159eny<\/li>\n<li>Pou\u017eijte v\u00edcebodov\u00e9 testov\u00e1n\u00ed nap\u011bt\u00ed na obou obvodech nez\u00e1visle<\/li>\n<li>P\u0159i pr\u00e1ci na obou obvodech zave\u010fte postupy blokov\u00e1n\u00ed\/ozna\u010dov\u00e1n\u00ed se DV\u011aMA SAMOSTATN\u00ddMI Z\u00c1MKY<\/li>\n<\/ul>\n<p><strong>Bezpe\u010dnost dvouokruhov\u00e9ho syst\u00e9mu DC1000V:<\/strong><\/p>\n<ul>\n<li>Pouze kvalifikovan\u00fd person\u00e1l \u2013 vy\u017eaduje se specializovan\u00e9 \u0161kolen\u00ed pro dvouokruhov\u00e9 syst\u00e9my<\/li>\n<li>V\u017edy pou\u017e\u00edvejte vhodn\u00e9 OOPP: izolovan\u00e9 rukavice (t\u0159\u00edda 2), ochrann\u00e9 br\u00fdle, od\u011bvy odoln\u00e9 proti oblouku<\/li>\n<li>Pou\u017e\u00edvejte pouze testovac\u00ed za\u0159\u00edzen\u00ed s jmenovit\u00fdm nap\u011bt\u00edm CAT III 1000V<\/li>\n<li>Uv\u011bdomte si, \u017ee v kabelech m\u016f\u017ee po odpojen\u00ed z\u016fstat kapacitn\u00ed n\u00e1boj<\/li>\n<\/ul>\n<p><strong>Provozn\u00ed bezpe\u010dnost:<\/strong><\/p>\n<ul>\n<li>P\u0159ed p\u0159\u00edstupem ke komponent\u00e1m dan\u00e9ho obvodu v\u017edy otev\u0159ete specifick\u00fd odpojova\u010d<\/li>\n<li>P\u0159ed otev\u0159en\u00edm krytu po\u010dkejte minim\u00e1ln\u011b 5 minut po odpojen\u00ed<\/li>\n<li>Pou\u017eijte detektor nap\u011bt\u00ed k ov\u011b\u0159en\u00ed nep\u0159\u00edtomnosti nap\u011bt\u00ed na dan\u00e9m obvodu<\/li>\n<li>Otestujte druh\u00fd obvod, abyste se ujistili, \u017ee z\u016fst\u00e1v\u00e1 izolovan\u00fd<\/li>\n<li>Nikdy nep\u0159ekra\u010dujte jmenovit\u00e9 nap\u011bt\u00ed (DC1000V) a proudov\u00e9 specifikace<\/li>\n<li>Neovl\u00e1dejte odpojova\u010de pod z\u00e1t\u011b\u017e\u00ed<\/li>\n<li>Udr\u017eujte jasnou identifikaci, kter\u00fd obvod je servisov\u00e1n<\/li>\n<\/ul>\n<h3>Doporu\u010den\u00ed pro \u00fadr\u017ebu:<\/h3>\n<p><strong>Pravideln\u00e1 kontrola (ka\u017ed\u00fdch 6 m\u011bs\u00edc\u016f):<\/strong><\/p>\n<ul>\n<li>Vizu\u00e1ln\u00ed kontrola obou obvod\u016f na zn\u00e1mky po\u0161kozen\u00ed nebo p\u0159eh\u0159\u00e1t\u00ed<\/li>\n<li>Zkontrolujte oba indik\u00e1tory SPD (zelen\u00e1 = OK, \u010derven\u00e1 = okam\u017eit\u011b vym\u011bnit)<\/li>\n<li>Zkontrolujte kryt, zda nem\u00e1 praskliny, po\u0161kozen\u00ed nebo naru\u0161en\u00e9 t\u011bsn\u011bn\u00ed<\/li>\n<li>Ov\u011b\u0159te, zda kabelov\u00e9 pr\u016fchodky udr\u017euj\u00ed spr\u00e1vnou integritu t\u011bsn\u011bn\u00ed na obou obvodech<\/li>\n<li>Zkontrolujte, zda se neobjevuj\u00ed zn\u00e1mky vniknut\u00ed vlhkosti<\/li>\n<li>Vizu\u00e1ln\u011b zkontrolujte stav pojistek ka\u017ed\u00e9ho obvodu<\/li>\n<li>Ov\u011b\u0159te, zda je bari\u00e9ra odd\u011bluj\u00edc\u00ed obvody neporu\u0161en\u00e1<\/li>\n<\/ul>\n<p><strong>Ro\u010dn\u00ed \u00fadr\u017eba:<\/strong><\/p>\n<ul>\n<li>Ov\u011b\u0159te, zda v\u0161echna p\u0159ipojen\u00ed z\u016fst\u00e1vaj\u00ed uta\u017een\u00e1 v ka\u017ed\u00e9m obvodu (dot\u00e1hn\u011bte: 1,2-1,5 Nm)<\/li>\n<li>Otestujte funkci ka\u017ed\u00e9ho sp\u00ednac\u00edho odp\u00edna\u010de jednotliv\u011b bez z\u00e1t\u011b\u017ee<\/li>\n<li>Prove\u010fte test izola\u010dn\u00edho odporu na ka\u017ed\u00e9m obvodu (m\u011blo by b\u00fdt &gt;200M\u03a9)<\/li>\n<li>Otestujte izolaci mezi obvody (m\u011blo by b\u00fdt &gt;200M\u03a9)<\/li>\n<li>O\u010dist\u011bte vn\u011bj\u0161\u00ed povrch krytu vlhk\u00fdm had\u0159\u00edkem<\/li>\n<li>Zkontrolujte vnit\u0159n\u00ed komponenty v ka\u017ed\u00e9m obvodu na zn\u00e1mky st\u00e1rnut\u00ed<\/li>\n<li>Ov\u011b\u0159te nap\u011bt\u00ed stringu na ka\u017ed\u00e9m obvodu nez\u00e1visle<\/li>\n<\/ul>\n<p><strong>V\u00fdm\u011bna komponent:<\/strong><\/p>\n<ul>\n<li>Vym\u011b\u0148te pojistky pouze za identick\u00e9 specifikace (15A gPV, DC1000V, 10x38mm, 30kA)<\/li>\n<li>V\u017edy vym\u011b\u0148te pojistky v p\u00e1rech (kladn\u00e1 a z\u00e1porn\u00e1) pro stejn\u00fd obvod<\/li>\n<li>V\u00fdm\u011bna SPD: pou\u017e\u00edvejte pouze VO-PV1000 nebo ekvivalentn\u00ed schv\u00e1len\u00fd model<\/li>\n<li>P\u0159i v\u00fdm\u011bn\u011b SPD je t\u0159eba odpojit pouze dan\u00fd obvod<\/li>\n<li>Ve\u010fte podrobn\u00fd z\u00e1znam o \u00fadr\u017eb\u011b pro ka\u017ed\u00fd obvod zvl\u00e1\u0161\u0165<\/li>\n<\/ul>\n<h3>Odstra\u0148ov\u00e1n\u00ed probl\u00e9m\u016f dvouokruhov\u00e9ho syst\u00e9mu:<\/h3>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<thead>\n<tr>\n<th>P\u0159\u00edznak<\/th>\n<th>Mo\u017en\u00e1 p\u0159\u00ed\u010dina<\/th>\n<th>\u0158e\u0161en\u00ed<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Obvod 1 bez v\u00fdstupu, Obvod 2 OK<\/td>\n<td>Pojistka obvodu 1 sp\u00e1len\u00e1<\/td>\n<td>Zkontrolujte\/vym\u011b\u0148te pouze pojistky obvodu 1, obvod 2 nen\u00ed ovlivn\u011bn<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Vyp\u00edna\u010d obvodu 1 VYPNUT\u00dd<\/td>\n<td>P\u0159epn\u011bte vyp\u00edna\u010d obvodu 1 do polohy ZAPNUTO<\/td>\n<\/tr>\n<tr>\n<td>Oba obvody bez v\u00fdstupu<\/td>\n<td>B\u011b\u017en\u00fd probl\u00e9m upstream<\/td>\n<td>Zkontrolujte p\u0159ipojen\u00ed na \u00farovni pole<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Oba vyp\u00edna\u010de VYPNUT\u00c9<\/td>\n<td>Ov\u011b\u0159te, zda jsou oba vyp\u00edna\u010de v poloze ZAPNUTO<\/td>\n<\/tr>\n<tr>\n<td>Jeden obvod se p\u0159eh\u0159\u00edv\u00e1<\/td>\n<td>Uvoln\u011bn\u00e9 p\u0159ipojen\u00ed v dan\u00e9m obvodu<\/td>\n<td>Dot\u00e1hn\u011bte svorky pouze v posti\u017een\u00e9m obvodu<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Poddimenzovan\u00fd kabel<\/td>\n<td>Ov\u011b\u0159te a upgradujte kabel pro dan\u00fd obvod<\/td>\n<\/tr>\n<tr>\n<td>Jeden indik\u00e1tor SPD \u010derven\u00fd<\/td>\n<td>SPD dan\u00e9ho obvodu na konci \u017eivotnosti<\/td>\n<td>Vym\u011b\u0148te SPD v posti\u017een\u00e9m obvodu, druh\u00fd pokra\u010duje v provozu<\/td>\n<\/tr>\n<tr>\n<td>Nevyv\u00e1\u017een\u00fd v\u00fdstup mezi obvody<\/td>\n<td>R\u016fzn\u00e9 konfigurace string\u016f<\/td>\n<td>Ov\u011b\u0159te n\u00e1vrh ka\u017ed\u00e9ho stringu nez\u00e1visle<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Degradace modulu v jednom stringu<\/td>\n<td>Prozkoumejte v\u00fdkon specifick\u00e9ho obvodu<\/td>\n<\/tr>\n<tr>\n<td>\u010cast\u00e9 selh\u00e1n\u00ed pojistek (jeden obvod)<\/td>\n<td>Zkrat v dan\u00e9m konkr\u00e9tn\u00edm stringu<\/td>\n<td>Zkontrolujte string pouze pro dan\u00fd obvod<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>P\u0159ekro\u010den\u00ed proudu<\/td>\n<td>Ov\u011b\u0159te, zda n\u00e1vrh stringu dan\u00e9ho obvodu &lt;15A<\/td>\n<\/tr>\n<tr>\n<td>Jeden obvod je p\u0159eru\u0161ovan\u00fd<\/td>\n<td>Vadn\u00e1 sou\u010d\u00e1stka v p\u0159eru\u0161ovan\u00e9m obvodu<\/td>\n<td>Izolujte a diagnostikujte dan\u00fd obvod nez\u00e1visle<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Technick\u00e9 srovn\u00e1n\u00ed: Konfigurace \u0159ady VOPV1000<\/h2>\n<h3>VOPV1000-2\/2 vs Ostatn\u00ed modely<\/h3>\n<table style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<thead>\n<tr>\n<th>Funkce<\/th>\n<th>VOPV1000-2\/2<\/th>\n<th>VOPV1000-1\/1<\/th>\n<th>VOPV1000-3\/1<\/th>\n<th>VOPV1000-3\/3<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Architektura<\/td>\n<td>2 Nez\u00e1visl\u00e9 obvody<\/td>\n<td>1 Obvod<\/td>\n<td>3 Spojen\u00e9 do 1<\/td>\n<td>3 Nez\u00e1visl\u00e9 obvody<\/td>\n<\/tr>\n<tr>\n<td>Stringov\u00e9 vstupy<\/td>\n<td>2<\/td>\n<td>1<\/td>\n<td>3<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>V\u00fdstupy<\/td>\n<td>2 Nez\u00e1visl\u00e9<\/td>\n<td>1<\/td>\n<td>1 Kombinovan\u00fd<\/td>\n<td>3 Nez\u00e1visl\u00e9<\/td>\n<\/tr>\n<tr>\n<td>Izolace obvod\u016f<\/td>\n<td>Kompletn\u00ed mezi 2<\/td>\n<td>NEUPLAT\u0147UJE SE<\/td>\n<td>\u017d\u00e1dn\u00e9 (kombinovan\u00e9)<\/td>\n<td>Kompletn\u00ed mezi 3<\/td>\n<\/tr>\n<tr>\n<td>Velikost sk\u0159\u00edn\u011b<\/td>\n<td>380x230x120mm<\/td>\n<td>218x200x100mm<\/td>\n<td>296x230x120mm<\/td>\n<td>296x550x130mm<\/td>\n<\/tr>\n<tr>\n<td>Odpojova\u010de<\/td>\n<td>2 jednotky<\/td>\n<td>1 jednotka<\/td>\n<td>1 jednotka<\/td>\n<td>3 jednotky<\/td>\n<\/tr>\n<tr>\n<td>SPD jednotky<\/td>\n<td>2 jednotky<\/td>\n<td>1 jednotka<\/td>\n<td>1 jednotka<\/td>\n<td>3 jednotky<\/td>\n<\/tr>\n<tr>\n<td>Pojistkov\u00e9 dr\u017e\u00e1ky<\/td>\n<td>4 (2 na string)<\/td>\n<td>2<\/td>\n<td>6 (2 na string)<\/td>\n<td>6 (2 na string)<\/td>\n<\/tr>\n<tr>\n<td>Hmotnost<\/td>\n<td>~4.5kg<\/td>\n<td>~2.2kg<\/td>\n<td>~3.5kg<\/td>\n<td>~6.5kg<\/td>\n<\/tr>\n<tr>\n<td>Ide\u00e1ln\u00ed velikost syst\u00e9mu<\/td>\n<td>10-15kW<\/td>\n<td>5-8kW<\/td>\n<td>10-15kW<\/td>\n<td>15-25kW<\/td>\n<\/tr>\n<tr>\n<td>Nejlep\u0161\u00ed aplikace<\/td>\n<td>Du\u00e1ln\u00ed st\u0159\u00edda\u010d, du\u00e1ln\u00ed MPPT, v\u00fdchod-z\u00e1pad<\/td>\n<td>Jednoduch\u00fd jedno-stringov\u00fd<\/td>\n<td>Jeden st\u0159\u00edda\u010d, v\u00edce string\u016f<\/td>\n<td>V\u00edce st\u0159\u00edda\u010d\u016f, maxim\u00e1ln\u00ed nez\u00e1vislost<\/td>\n<\/tr>\n<tr>\n<td>Podpora du\u00e1ln\u00edho st\u0159\u00edda\u010de<\/td>\n<td>Vynikaj\u00edc\u00ed<\/td>\n<td>Ne<\/td>\n<td>Ne<\/td>\n<td>V\u00fdborn\u00e1 (a\u017e 3)<\/td>\n<\/tr>\n<tr>\n<td>Podpora du\u00e1ln\u00edho MPPT<\/td>\n<td>Vynikaj\u00edc\u00ed<\/td>\n<td>Ne<\/td>\n<td>Omezen\u00e9<\/td>\n<td>V\u00fdborn\u00e1 (a\u017e 3)<\/td>\n<\/tr>\n<tr>\n<td>Optimalizace v\u00fdchod-z\u00e1pad<\/td>\n<td>Perfektn\u00ed<\/td>\n<td>Ne<\/td>\n<td>Mo\u017en\u00e9, ale kombinovan\u00e9<\/td>\n<td>V\u00fdborn\u00e1 (plus t\u0159et\u00ed orientace)<\/td>\n<\/tr>\n<tr>\n<td>\u00darove\u0148 n\u00e1klad\u016f<\/td>\n<td>St\u0159edn\u00ed<\/td>\n<td>N\u00edzk\u00e1<\/td>\n<td>St\u0159edn\u00ed<\/td>\n<td>Vysok\u00e1<\/td>\n<\/tr>\n<tr>\n<td>Flexibilita<\/td>\n<td>Vysok\u00e1<\/td>\n<td>N\u00edzk\u00e1<\/td>\n<td>St\u0159edn\u00ed<\/td>\n<td>Velmi vysok\u00e1<\/td>\n<\/tr>\n<tr>\n<td>Doba odst\u00e1vky \u00fadr\u017eby<\/td>\n<td>Minim\u00e1ln\u00ed (zachov\u00e1na kapacita 50%)<\/td>\n<td>Cel\u00fd syst\u00e9m<\/td>\n<td>Cel\u00fd syst\u00e9m<\/td>\n<td>Minim\u00e1ln\u00ed (zachov\u00e1na kapacita 67-100%)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>V\u00fdb\u011br spr\u00e1vn\u00e9 konfigurace<\/h3>\n<p><strong>Vyberte VOPV1000-2\/2, kdy\u017e:<\/strong><\/p>\n<ul>\n<li>Pou\u017e\u00edv\u00e1te du\u00e1ln\u00ed st\u0159\u00edda\u010d nebo du\u00e1ln\u00ed MPPT st\u0159\u00edda\u010dov\u00fd syst\u00e9m<\/li>\n<li>Instalujete pole s orientac\u00ed v\u00fdchod-z\u00e1pad<\/li>\n<li>Pot\u0159ebujete kompletn\u00ed nez\u00e1vislost obvod\u016f pro dva stringy<\/li>\n<li>Chcete optim\u00e1ln\u00ed pom\u011br cena\/v\u00fdkon pro pot\u0159eby du\u00e1ln\u00edho obvodu<\/li>\n<li>Po\u017eadujete flexibilitu pro f\u00e1zovanou instalaci (2 f\u00e1ze)<\/li>\n<li>Pot\u0159ebujete provoz syst\u00e9mu 50% b\u011bhem \u00fadr\u017eby<\/li>\n<\/ul>\n<p><strong>Zvolte VOPV1000-1\/1, kdy\u017e:<\/strong><\/p>\n<ul>\n<li>Jednoduch\u00fd syst\u00e9m s jedn\u00edm stringem (5-8kW)<\/li>\n<li>Jedna orientace, jeden st\u0159\u00edda\u010d<\/li>\n<li>Priorita minim\u00e1ln\u00edch n\u00e1klad\u016f<\/li>\n<li>Prostorov\u00e1 omezen\u00ed<\/li>\n<\/ul>\n<p><strong>Zvolte VOPV1000-3\/1, kdy\u017e:<\/strong><\/p>\n<ul>\n<li>V\u00edce string\u016f k jednomu st\u0159\u00edda\u010di<\/li>\n<li>St\u0159\u00edda\u010d s jedn\u00edm MPPT vstupem<\/li>\n<li>Priorita optimalizace n\u00e1klad\u016f<\/li>\n<li>Nepot\u0159ebujete nez\u00e1visl\u00e9 \u0159\u00edzen\u00ed obvod\u016f<\/li>\n<\/ul>\n<p><strong>Zvolte VOPV1000-3\/3, kdy\u017e:<\/strong><\/p>\n<ul>\n<li>T\u0159i samostatn\u00e9 st\u0159\u00edda\u010de nebo st\u0159\u00edda\u010d se t\u0159emi MPPT<\/li>\n<li>Po\u017eadujete maxim\u00e1ln\u00ed flexibilitu a redundanci<\/li>\n<li>T\u0159i r\u016fzn\u00e9 orientace<\/li>\n<li>Kritick\u00e9 aplikace vy\u017eaduj\u00edc\u00ed maxim\u00e1ln\u00ed spolehlivost<\/li>\n<li>V\u011bt\u0161\u00ed velikost syst\u00e9mu (15-25kW)<\/li>\n<\/ul>\n<h2>Pro\u010d zvolit VIOX VOPV1000-2\/2?<\/h2>\n<p><strong>Perfektn\u00ed \u0159e\u0161en\u00ed pro du\u00e1ln\u00ed obvod<\/strong><\/p>\n<ul>\n<li>Dva kompletn\u011b izolovan\u00e9 obvody eliminuj\u00ed ru\u0161en\u00ed mezi obvody<\/li>\n<li>Optim\u00e1ln\u00ed rovnov\u00e1ha mezi nez\u00e1vislost\u00ed a n\u00e1kladovou efektivitou<\/li>\n<li>Ide\u00e1ln\u00ed pro v\u011bt\u0161inu aplikac\u00ed s du\u00e1ln\u00ed orientac\u00ed a du\u00e1ln\u00edm st\u0159\u00edda\u010dem<\/li>\n<li>Pokra\u010dujte v provozu s kapacitou 50%, pokud m\u00e1 jeden obvod probl\u00e9my<\/li>\n<\/ul>\n<p><strong>Vynikaj\u00edc\u00ed syst\u00e9m V\u00fdchod-Z\u00e1pad<\/strong><\/p>\n<ul>\n<li>Vyrobeno na m\u00edru pro sol\u00e1rn\u00ed pole orientovan\u00e1 na v\u00fdchod-z\u00e1pad<\/li>\n<li>Maximalizuje denn\u00ed profil v\u00fdroby energie<\/li>\n<li>Sni\u017euje zat\u00ed\u017een\u00ed s\u00edt\u011b s prodlou\u017eenou genera\u010dn\u00ed k\u0159ivkou<\/li>\n<li>Optim\u00e1ln\u00ed \u0159e\u0161en\u00ed pro sol\u00e1rn\u00ed instalace \u0161etrn\u00e9 k s\u00edti<\/li>\n<\/ul>\n<p><strong>Optimalizace du\u00e1ln\u00edho st\u0159\u00edda\u010de a du\u00e1ln\u00edho MPPT<\/strong><\/p>\n<ul>\n<li>P\u0159\u00edm\u00e9 p\u0159ipojen\u00ed ke dv\u011bma samostatn\u00fdm stringov\u00fdm st\u0159\u00edda\u010d\u016fm<\/li>\n<li>Ide\u00e1ln\u00ed pro syst\u00e9my se st\u0159\u00edda\u010di s du\u00e1ln\u00edm MPPT<\/li>\n<li>Nez\u00e1visl\u00e1 optimalizace pro ka\u017edou orientaci<\/li>\n<li>Lep\u0161\u00ed v\u00fdkon ne\u017e kombinovan\u00e9 konfigurace<\/li>\n<\/ul>\n<p><strong>Vynikaj\u00edc\u00ed pom\u011br cena\/v\u00fdkon<\/strong><\/p>\n<ul>\n<li>Ekonomi\u010dt\u011bj\u0161\u00ed ne\u017e 3\/3 pro pot\u0159eby dvou obvod\u016f<\/li>\n<li>Vy\u0161\u0161\u00ed hodnota ne\u017e 1\/1 d\u00edky du\u00e1ln\u00ed schopnosti<\/li>\n<li>Optim\u00e1ln\u00ed po\u010det komponent pro architekturu du\u00e1ln\u00edho obvodu<\/li>\n<li>Nejlep\u0161\u00ed rovnov\u00e1ha mezi funkcemi a cenou<\/li>\n<\/ul>\n<p><strong>Profesion\u00e1ln\u00ed in\u017een\u00fdrstv\u00ed<\/strong><\/p>\n<ul>\n<li>Sk\u0159\u00ed\u0148 VOAT-18 efektivn\u011b pojme du\u00e1ln\u00ed obvody<\/li>\n<li>Optimalizovan\u00e9 vnit\u0159n\u00ed uspo\u0159\u00e1d\u00e1n\u00ed s jasn\u00fdm odd\u011blen\u00edm obvod\u016f<\/li>\n<li>Pr\u00e9miov\u00e9 komponenty dimenzovan\u00e9 speci\u00e1ln\u011b pro aplikace DC1000V<\/li>\n<li>Vylep\u0161en\u00e1 koordinace izolace pro dlouhodobou spolehlivost<\/li>\n<\/ul>\n<p><strong>Provozn\u00ed excelence<\/strong><\/p>\n<ul>\n<li>Individu\u00e1ln\u00ed \u0159\u00edzen\u00ed obvod\u016f zvy\u0161uje flexibilitu<\/li>\n<li>Zjednodu\u0161en\u00e1 \u00fadr\u017eba pomoc\u00ed sp\u00edna\u010d\u016f pro ka\u017ed\u00fd obvod<\/li>\n<li>Zkr\u00e1cen\u00ed prostoj\u016f d\u00edky izolaci poruch<\/li>\n<li>Mo\u017enost f\u00e1zovan\u00e9ho uveden\u00ed do provozu<\/li>\n<\/ul>\n<p><strong>Dlouhodob\u00e1 hodnota<\/strong><\/p>\n<ul>\n<li>Vy\u0161\u0161\u00ed spolehlivost d\u00edky du\u00e1ln\u00edm ochrann\u00fdm syst\u00e9m\u016fm<\/li>\n<li>Lep\u0161\u00ed v\u00fdnos energie d\u00edky optimalizaci orientace<\/li>\n<li>Ni\u017e\u0161\u00ed celkov\u00e9 n\u00e1klady na vlastnictv\u00ed<\/li>\n<li>Ochrana investic prost\u0159ednictv\u00edm flexibility<\/li>\n<li>Prodlou\u017een\u00e1 \u017eivotnost syst\u00e9mu d\u00edky redundanci<\/li>\n<\/ul>\n<h2>Kontaktujte n\u00e1s<\/h2>\n<p>Jste p\u0159ipraveni optimalizovat svou sol\u00e1rn\u00ed instalaci s du\u00e1ln\u00ed orientac\u00ed nebo du\u00e1ln\u00edm st\u0159\u00edda\u010dem pomoc\u00ed slu\u010dovac\u00ed sk\u0159\u00edn\u011b VOPV1000-2\/2? Kontaktujte spole\u010dnost VIOX Electric je\u0161t\u011b dnes pro:<\/p>\n<ul>\n<li>Podrobn\u00e9 technick\u00e9 specifikace a CAD v\u00fdkresy<\/li>\n<li>Konzultace n\u00e1vrhu syst\u00e9mu s du\u00e1ln\u00edm st\u0159\u00edda\u010dem a du\u00e1ln\u00edm MPPT<\/li>\n<li>Poradenstv\u00ed pro optimalizaci syst\u00e9mu s orientac\u00ed na v\u00fdchod-z\u00e1pad<\/li>\n<li>Doporu\u010den\u00ed pro nez\u00e1vislou konfiguraci du\u00e1ln\u00edho obvodu<\/li>\n<li>Konkuren\u010dn\u00ed ceny a informace o MOQ (minim\u00e1ln\u00ed objednac\u00ed mno\u017estv\u00ed)<\/li>\n<li>Mo\u017enosti konfigurace na m\u00edru pro specifick\u00e9 po\u017eadavky projektu<\/li>\n<li>Vzorov\u00e9 objedn\u00e1vky pro testov\u00e1n\u00ed a vyhodnocen\u00ed<\/li>\n<li>Cenov\u00e9 nab\u00eddky pro hromadn\u00e9 objedn\u00e1vky s mno\u017estevn\u00edmi slevami<\/li>\n<li>\u010casov\u00e1 osa dod\u00e1n\u00ed a podpora mezin\u00e1rodn\u00ed logistiky<\/li>\n<li>Specializovan\u00e9 \u0161kolen\u00ed instalace pro nez\u00e1vislou konfiguraci 2\/2<\/li>\n<li>Produktov\u00e9 certifikace a dokumentace o shod\u011b<\/li>\n<li>Podpora integrace pro syst\u00e9my s du\u00e1ln\u00edm st\u0159\u00edda\u010dem<\/li>\n<li>Doporu\u010den\u00ed pro monitorovac\u00ed syst\u00e9m na \u00farovni stringu<\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Maximalizujte svou sol\u00e1rn\u00ed \u00fa\u010dinnost s <strong>VIOX VOPV1000-2\/2<\/strong>, specializovan\u00fdm <strong>2-okruhov\u00fdm nez\u00e1visl\u00fdm sol\u00e1rn\u00edm slu\u010dova\u010dem<\/strong>. Navr\u017eeno pro <strong>DC1000V<\/strong> syst\u00e9my, tato jednotka obsahuje <strong>2 kompletn\u011b izolovan\u00e9 vstupy a v\u00fdstupy<\/strong>, co\u017e z n\u011bj \u010din\u00ed perfektn\u00ed volbu pro du\u00e1ln\u00ed MPPT st\u0159\u00edda\u010de a v\u00fdchodo-z\u00e1padn\u011b orientovan\u00e1 pole.<\/p>\n<ul style=\"margin-top: 10px; margin-bottom: 10px;\">\n<li><strong>Konfigurace:<\/strong> 2 vstupy \/ 2 nez\u00e1visl\u00e9 v\u00fdstupy (2-in-2-out)<\/li>\n<li><strong>Izolace:<\/strong> 100% Elektrick\u00e9 odd\u011blen\u00ed mezi stringy<\/li>\n<li><strong>P\u0159ipraveno pro du\u00e1ln\u00ed MPPT:<\/strong> P\u0159ipojuje se p\u0159\u00edmo ke 2 samostatn\u00fdm vstup\u016fm st\u0159\u00edda\u010de<\/li>\n<li><strong>Ochrana:<\/strong> 2x DC sp\u00edna\u010de, 2x SPD typu 2, 4x pojistky<\/li>\n<li><strong>Proud:<\/strong> 45A na okruh (celkem 2 okruhy)<\/li>\n<li><strong>Kryt:<\/strong> IP65 Vodot\u011bsn\u00fd ABS (VOAT-18)<\/li>\n<\/ul>\n<p>Ide\u00e1ln\u00ed <strong>\u0159e\u0161en\u00ed ochrany FV<\/strong> pro optimalizaci energetick\u00e9ho zisku v reziden\u010dn\u00edch a komer\u010dn\u00edch projektech s du\u00e1ln\u00ed orientac\u00ed.<\/p>","protected":false},"featured_media":20939,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[115,135],"product_tag":[],"class_list":{"0":"post-20937","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-new-energy-series","7":"product_cat-combiner-box","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product\/20937","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/comments?post=20937"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media\/20939"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media?parent=20937"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product_brand?post=20937"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product_cat?post=20937"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product_tag?post=20937"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}