{"id":14987,"date":"2025-03-31T16:34:21","date_gmt":"2025-03-31T08:34:21","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=14987"},"modified":"2025-03-31T16:37:41","modified_gmt":"2025-03-31T08:37:41","slug":"vopv-dc-isolator-switch-nl1-series","status":"publish","type":"product","link":"https:\/\/test.viox.com\/cs\/produkt\/vopv-dc-isolator-switch-nl1-series\/","title":{"rendered":"Izol\u00e1torov\u00fd sp\u00edna\u010d stejnosm\u011brn\u00e9ho proudu VOPV \u0159ady NL1"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>Komplexn\u00ed p\u0159ehled<\/h2>\n<p>Izol\u00e1torov\u00e9 sp\u00edna\u010de VOPV \u0159ady NL1 p\u0159edstavuj\u00ed vrchol bezpe\u010dnosti a spolehlivosti v oblasti ochrany fotovoltaick\u00fdch syst\u00e9m\u016f. Tyto odd\u011blovac\u00ed sp\u00edna\u010de, navr\u017een\u00e9 speci\u00e1ln\u011b pro reziden\u010dn\u00ed a komer\u010dn\u00ed sol\u00e1rn\u00ed instalace o v\u00fdkonu od 1 do 20 kW, slou\u017e\u00ed jako kritick\u00e9 bezpe\u010dnostn\u00ed komponenty, kter\u00e9 zaji\u0161\u0165uj\u00ed \u00faplnou elektrickou izolaci mezi sol\u00e1rn\u00edmi panely a st\u0159\u00edda\u010di. D\u00edky vynikaj\u00edc\u00edm v\u00fdkonnostn\u00edm vlastnostem a souladu s mezin\u00e1rodn\u00edmi bezpe\u010dnostn\u00edmi normami je \u0159ada NL1 nezbytnou sou\u010d\u00e1st\u00ed ka\u017ed\u00e9 sol\u00e1rn\u00ed instalace, kter\u00e1 usiluje o dokonal\u00fd provoz a dlouhodobou \u017eivotnost.<\/p>\n<h2>Z\u00e1kladn\u00ed bezpe\u010dnostn\u00ed \u0159e\u0161en\u00ed pro sol\u00e1rn\u00ed syst\u00e9my<\/h2>\n<p>P\u0159i instalaci sol\u00e1rn\u00edch za\u0159\u00edzen\u00ed je nejd\u016fle\u017eit\u011bj\u0161\u00ed bezpe\u010dnost. Izola\u010dn\u00ed sp\u00edna\u010de VOPV \u0159ady NL1 funguj\u00ed jako za\u0159\u00edzen\u00ed pro nouzov\u00e9 odpojen\u00ed a umo\u017e\u0148uj\u00ed \u00fapln\u00e9 odd\u011blen\u00ed fotovoltaick\u00fdch panel\u016f od zbytku syst\u00e9mu. Tato schopnost izolace je kl\u00ed\u010dov\u00e1 p\u0159i \u00fadr\u017eb\u011b, modernizaci syst\u00e9mu nebo v nouzov\u00fdch situac\u00edch, kdy \u00fa\u010dinn\u011b zabra\u0148uje elektrick\u00fdm nehod\u00e1m a potenci\u00e1ln\u00edmu po\u0161kozen\u00ed za\u0159\u00edzen\u00ed. D\u00edky p\u016fsobiv\u00e9 dob\u011b obloukov\u00e9ho v\u00fdboje krat\u0161\u00ed ne\u017e 8 ms zaji\u0161\u0165uj\u00ed tyto odpojova\u010de rychl\u00e9 odpojen\u00ed, \u010d\u00edm\u017e v\u00fdrazn\u011b sni\u017euj\u00ed riziko vzniku obloukov\u00e9ho v\u00fdboje, kter\u00fd m\u016f\u017ee ohrozit integritu syst\u00e9mu a bezpe\u010dnost obsluhy.<\/p>\n<h2>Kl\u00ed\u010dov\u00e9 aplikace<\/h2>\n<p>D\u00edky sv\u00e9 univerz\u00e1lnosti je stejnosm\u011brn\u00fd izol\u00e1tor VOPV \u0159ady NL1 vhodn\u00fd pro \u0161irokou \u0161k\u00e1lu fotovoltaick\u00fdch aplikac\u00ed, v\u010detn\u011b:<\/p>\n<ul>\n<li>St\u0159e\u0161n\u00ed sol\u00e1rn\u00ed instalace pro obyvatele (1-10 kW)<\/li>\n<li>Komer\u010dn\u00ed sol\u00e1rn\u00ed syst\u00e9my (10-20 kW)<\/li>\n<li>Mal\u00e9 sol\u00e1rn\u00ed farmy<\/li>\n<li>Sol\u00e1rn\u00ed syst\u00e9my mimo s\u00ed\u0165<\/li>\n<li>Integrace bateriov\u00fdch \u00falo\u017en\u00fdch syst\u00e9m\u016f<\/li>\n<li>Sol\u00e1rn\u00ed syst\u00e9my pro \u010derp\u00e1n\u00ed vody<\/li>\n<\/ul>\n<h3>Technick\u00e1 dokonalost a robustn\u00ed design<\/h3>\n<p>Izola\u010dn\u00ed sp\u00edna\u010d stejnosm\u011brn\u00e9ho proudu \u0159ady NL1 je precizn\u011b navr\u017een tak, aby spl\u0148oval n\u00e1ro\u010dn\u00e9 po\u017eadavky fotovoltaick\u00fdch aplikac\u00ed. T\u011bleso sp\u00edna\u010de je vhodn\u00e9 pro konfigurace 4P CB4N nebo CB8N, co\u017e poskytuje flexibiln\u00ed mo\u017enosti instalace. D\u00edky maxim\u00e1ln\u00edmu provozn\u00edmu nap\u011bt\u00ed 1200 V DC jsou tyto odd\u011blovac\u00ed sp\u00edna\u010de kompatibiln\u00ed s modern\u00edmi vysokonap\u011b\u0165ov\u00fdmi sol\u00e1rn\u00edmi poli a zaji\u0161\u0165uj\u00ed optim\u00e1ln\u00ed v\u00fdkon a bezpe\u010dnost v r\u016fzn\u00fdch konfigurac\u00edch syst\u00e9mu.<\/p>\n<h2>Pr\u00e9miov\u00e9 funkce izol\u00e1torov\u00fdch sp\u00edna\u010d\u016f \u0159ady VOPV NL1<\/h2>\n<h3>Zv\u00fd\u0161en\u00e9 bezpe\u010dnostn\u00ed vlastnosti<\/h3>\n<ul>\n<li><strong>Stupe\u0148 kryt\u00ed IP20:<\/strong> Poskytuje spolehlivou ochranu proti vniknut\u00ed pevn\u00fdch p\u0159edm\u011bt\u016f v\u011bt\u0161\u00edch ne\u017e 12 mm a zaji\u0161\u0165uje provozn\u00ed integritu v r\u016fzn\u00fdch instala\u010dn\u00edch prost\u0159ed\u00edch.<\/li>\n<li><strong>Doba rychl\u00e9ho oblouku:<\/strong> D\u00edky rychl\u00e9mu odpojen\u00ed za m\u00e9n\u011b ne\u017e 8 ms se minimalizuje nebezpe\u010d\u00ed vzniku obloukov\u00e9ho v\u00fdboje, co\u017e zvy\u0161uje celkovou bezpe\u010dnost syst\u00e9mu.<\/li>\n<li><strong>Vysok\u00e9 izola\u010dn\u00ed nap\u011bt\u00ed:<\/strong> Jmenovit\u00e9 nap\u011bt\u00ed 1200 V zaji\u0161\u0165uje \u00faplnou elektrickou izolaci mezi vstupn\u00edmi a v\u00fdstupn\u00edmi obvody.<\/li>\n<li><strong>Kategorie p\u0159ep\u011bt\u00ed II:<\/strong> Navr\u017eeno tak, aby odolalo do\u010dasn\u00fdm p\u0159ep\u011b\u0165ov\u00fdm situac\u00edm b\u011b\u017en\u00fdm ve fotovoltaick\u00fdch syst\u00e9mech.<\/li>\n<li><strong>Jmenovit\u00e9 impulzn\u00ed v\u00fddr\u017en\u00e9 nap\u011bt\u00ed:<\/strong> Ochrana 8,0 kV proti p\u0159ep\u011bt\u00ed, kter\u00e1 chr\u00e1n\u00ed p\u0159ipojen\u00e1 za\u0159\u00edzen\u00ed.<\/li>\n<\/ul>\n<h3>V\u00fdhody instalace a provozu<\/h3>\n<ul>\n<li><strong>Mont\u00e1\u017e na li\u0161tu DIN:<\/strong> Usnad\u0148uje jednoduchou instalaci do standardn\u00edch elektrick\u00fdch sk\u0159\u00edn\u00ed a rozv\u00e1d\u011b\u010d\u016f.<\/li>\n<li><strong>V\u00edce konfigurac\u00ed p\u00f3l\u016f:<\/strong> K dispozici jsou ve 2p\u00f3lov\u00e9m a 4p\u00f3lov\u00e9m proveden\u00ed pro jedno- a dvoustrunn\u00e9 aplikace.<\/li>\n<li><strong>V\u0161estrann\u00e9 proudov\u00e9 dimenze:<\/strong> Vyberte si z 16A, 25A nebo 32A variant, kter\u00e9 odpov\u00eddaj\u00ed va\u0161im specifick\u00fdm syst\u00e9mov\u00fdm po\u017eadavk\u016fm.<\/li>\n<li><strong>Kompatibilita s flexibiln\u00edm nap\u011bt\u00edm:<\/strong> Pracuje v r\u016fzn\u00fdch nap\u011b\u0165ov\u00fdch rozsaz\u00edch v\u010detn\u011b 300 V, 600 V, 800 V, 1000 V a 1200 V DC.<\/li>\n<li><strong>Nepolarizovan\u00fd design:<\/strong> \u017d\u00e1dn\u00e9 omezen\u00ed polarity umo\u017e\u0148uje zam\u011bniteln\u00e9 p\u0159ipojen\u00ed \"+\" a \"-\", co\u017e zjednodu\u0161uje instala\u010dn\u00ed postupy.<\/li>\n<\/ul>\n<h3>Odolnost a \u017eivotnost<\/h3>\n<ul>\n<li><strong>Vynikaj\u00edc\u00ed mechanick\u00e1 odolnost:<\/strong> Testov\u00e1no na 18 000 operac\u00ed, co\u017e zaji\u0161\u0165uje prodlou\u017eenou \u017eivotnost i v syst\u00e9mech s \u010dast\u00fdmi po\u017eadavky na p\u0159ep\u00edn\u00e1n\u00ed.<\/li>\n<li><strong>Vynikaj\u00edc\u00ed elektrick\u00e1 odolnost:<\/strong> Je dimenzov\u00e1n na 2 000 elektrick\u00fdch operac\u00ed p\u0159i zat\u00ed\u017een\u00ed, co\u017e zaji\u0161\u0165uje spolehliv\u00fd v\u00fdkon po celou dobu \u017eivotnosti syst\u00e9mu.<\/li>\n<li><strong>Vysok\u00e1 zkratov\u00e1 odolnost:<\/strong> Dok\u00e1\u017ee zpracovat 1 kA po dobu 1 sekundy a chr\u00e1n\u00ed syst\u00e9m p\u0159i poruchov\u00fdch stavech.<\/li>\n<li><strong>V\u00fdb\u011br kvalitn\u00edch komponent:<\/strong> Vyrobeno z prvot\u0159\u00eddn\u00edch materi\u00e1l\u016f vybran\u00fdch speci\u00e1ln\u011b pro jejich v\u00fdkon v aplikac\u00edch stejnosm\u011brn\u00e9ho proudu.<\/li>\n<\/ul>\n<h2>Technick\u00e9 specifikace<\/h2>\n<h3>Varianty model\u016f<\/h3>\n<table class=\"specs-table\">\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Aktu\u00e1ln\u00ed hodnocen\u00ed<\/th>\n<th>Aplikace<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>VOPV16-NL1<\/td>\n<td>16A<\/td>\n<td>Mal\u00e9 obytn\u00e9 syst\u00e9my<\/td>\n<\/tr>\n<tr>\n<td>VOPV25-NL1<\/td>\n<td>25A<\/td>\n<td>St\u0159edn\u00ed obytn\u00e9 a mal\u00e9 komer\u010dn\u00ed syst\u00e9my<\/td>\n<\/tr>\n<tr>\n<td>VOPV32-NL1<\/td>\n<td>32A<\/td>\n<td>Velk\u00e9 obytn\u00e9 a st\u0159edn\u00ed komer\u010dn\u00ed instalace<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Elektrick\u00e9 charakteristiky<\/h3>\n<table class=\"specs-table\">\n<tbody>\n<tr>\n<td>Dodr\u017eov\u00e1n\u00ed standard\u016f<\/td>\n<td>IEC60947-3, AS60947.3<\/td>\n<\/tr>\n<tr>\n<td>Kategorie vyu\u017eit\u00ed<\/td>\n<td>DC-PV2, DC-PV1, DC-21B<\/td>\n<\/tr>\n<tr>\n<td>Konfigurace p\u00f3l\u016f<\/td>\n<td>4P<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00e1 frekvence<\/td>\n<td>DC<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00e9 provozn\u00ed nap\u011bt\u00ed (Ue)<\/td>\n<td>300 V, 600 V, 800 V, 1000 V, 1200 V<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00e9 izola\u010dn\u00ed nap\u011bt\u00ed (Ui)<\/td>\n<td>1200V<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00fd kr\u00e1tkodob\u00fd v\u00fddr\u017en\u00fd proud (Icw)<\/td>\n<td>1kA, 1s<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00e9 impulzn\u00ed v\u00fddr\u017en\u00e9 nap\u011bt\u00ed (Uimp)<\/td>\n<td>8,0 kV<\/td>\n<\/tr>\n<tr>\n<td>Kategorie p\u0159ep\u011bt\u00ed<\/td>\n<td>II<\/td>\n<\/tr>\n<tr>\n<td>Vhodnost izolace<\/td>\n<td>ANO<\/td>\n<\/tr>\n<tr>\n<td>Polarita<\/td>\n<td>\u017d\u00e1dn\u00e1 polarita, polaritu \"+\" a \"-\" lze zam\u011bnit.<\/td>\n<\/tr>\n<tr>\n<td>Ochrana proti vniknut\u00ed \/ t\u011blo sp\u00edna\u010de<\/td>\n<td>IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Charakteristiky trvanlivosti<\/h3>\n<table class=\"specs-table\">\n<tbody>\n<tr>\n<td>Mechanick\u00e9 operace<\/td>\n<td>18,000<\/td>\n<\/tr>\n<tr>\n<td>Elektrick\u00e9 operace<\/td>\n<td>2,000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Rozm\u011br<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-14988\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1-Series-dimension.webp\" alt=\"VOPV DC Isolator Switch NL1 Series dimension\" width=\"728\" height=\"500\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1-Series-dimension.webp 728w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1-Series-dimension-300x206.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1-Series-dimension-18x12.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1-Series-dimension-600x412.webp 600w\" sizes=\"(max-width: 728px) 100vw, 728px\" \/><\/p>\n<h2>Zapojen\u00ed<\/h2>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14989\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1-Series-wiring.webp\" alt=\"VOPV DC Isolator Switch NL1 Series wiring\" width=\"580\" height=\"486\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1-Series-wiring.webp 580w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1-Series-wiring-300x251.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1-Series-wiring-14x12.webp 14w\" sizes=\"(max-width: 580px) 100vw, 580px\" \/><\/p>\n<h2>Instalace a bezpe\u010dnostn\u00ed opat\u0159en\u00ed<\/h2>\n<h3>Optim\u00e1ln\u00ed instala\u010dn\u00ed postupy<\/h3>\n<p>Pro dosa\u017een\u00ed maxim\u00e1ln\u00ed bezpe\u010dnosti a v\u00fdkonu by m\u011bly b\u00fdt stejnosm\u011brn\u00e9 izola\u010dn\u00ed sp\u00edna\u010de \u0159ady NL1 instalov\u00e1ny podle t\u011bchto pokyn\u016f:<\/p>\n<ul>\n<li>Bezpe\u010dn\u00e1 mont\u00e1\u017e na standardn\u00ed 35mm li\u0161ty DIN ve vhodn\u00fdch elektrick\u00fdch sk\u0159\u00edn\u00edch.<\/li>\n<li>Zajist\u011bte dostate\u010dn\u00e9 v\u011btr\u00e1n\u00ed, aby nedoch\u00e1zelo k akumulaci tepla.<\/li>\n<li>Um\u00edst\u011bte na p\u0159\u00edstupn\u00e1 m\u00edsta, abyste usnadnili nouzov\u00e9 odpojen\u00ed.<\/li>\n<li>Chra\u0148te p\u0159ed p\u0159\u00edm\u00fdm p\u016fsoben\u00edm okoln\u00edch vliv\u016f<\/li>\n<li>Pou\u017eijte vhodn\u00e9 velikosti kabel\u016f odpov\u00eddaj\u00edc\u00ed jmenovit\u00fdm proud\u016fm zvolen\u00e9ho modelu izol\u00e1toru.<\/li>\n<li>Dodr\u017eujte m\u00edstn\u00ed elektrick\u00e9 p\u0159edpisy a na\u0159\u00edzen\u00ed pro instalaci fotovoltaick\u00fdch syst\u00e9m\u016f.<\/li>\n<li>Prov\u00e1d\u011bn\u00ed pravideln\u00fdch kontrol \u00fadr\u017eby k zaji\u0161t\u011bn\u00ed trval\u00e9 provozn\u00ed integrity<\/li>\n<\/ul>\n<h3>Konfigurace zapojen\u00ed<\/h3>\n<p>\u0158ada VOPV NL1 nab\u00edz\u00ed flexibiln\u00ed mo\u017enosti p\u0159ipojen\u00ed, k dispozici jsou 2p\u00f3lov\u00e9 i 4p\u00f3lov\u00e9 konfigurace:<\/p>\n<ul>\n<li><strong>Dvoup\u00f3lov\u00e1 konfigurace (2P):<\/strong> Vhodn\u00e9 pro jednopramenn\u00e9 aplikace se svorkami 1-2 a 3-4 pro p\u0159ipojen\u00ed kladn\u00e9ho a z\u00e1porn\u00e9ho vodi\u010de.<\/li>\n<li><strong>\u010cty\u0159p\u00f3lov\u00e1 konfigurace (4P):<\/strong> Je navr\u017een pro dvoustrunn\u00e9 sestavy a poskytuje svorky 1-2, 3-4, 5-6 a 7-8 pro komplexn\u00ed izolaci v\u00edce strun.<\/li>\n<\/ul>\n<h2>Dodr\u017eov\u00e1n\u00ed p\u0159edpis\u016f a certifikace<\/h2>\n<p>Izol\u00e1torov\u00e9 sp\u00edna\u010de VOPV \u0159ady NL1 jsou vyr\u00e1b\u011bny v p\u0159\u00edsn\u00e9m souladu s mezin\u00e1rodn\u00edmi bezpe\u010dnostn\u00edmi normami, co\u017e zaru\u010duje spolehliv\u00fd v\u00fdkon a shodu s p\u0159edpisy:<\/p>\n<ul>\n<li><strong>IEC60947-3:<\/strong> Mezin\u00e1rodn\u00ed norma pro n\u00edzkonap\u011b\u0165ov\u00e9 sp\u00ednac\u00ed a \u0159\u00eddic\u00ed p\u0159\u00edstroje<\/li>\n<li><strong>AS60947.3:<\/strong> Australsk\u00e1 norma pro n\u00edzkonap\u011b\u0165ov\u00e9 sp\u00ednac\u00ed a \u0159\u00eddic\u00ed p\u0159\u00edstroje<\/li>\n<li><strong>DC-PV2, DC-PV1, DC-21B:<\/strong> Kategorie vyu\u017eit\u00ed speci\u00e1ln\u011b pro fotovoltaick\u00e9 aplikace<\/li>\n<\/ul>\n<h2>V\u00fdhody oproti konkuren\u010dn\u00edm produkt\u016fm<\/h2>\n<p>Izol\u00e1torov\u00e9 sp\u00edna\u010de stejnosm\u011brn\u00e9ho proudu \u0159ady VOPV NL1 nab\u00edzej\u00ed n\u011bkolik v\u00fdrazn\u00fdch v\u00fdhod, kter\u00e9 je odli\u0161uj\u00ed od konkuren\u010dn\u00edch v\u00fdrobk\u016f na trhu:<\/p>\n<h3>Vylep\u0161en\u00e9 bezpe\u010dnostn\u00ed funkce<\/h3>\n<ul>\n<li>Rychlej\u0161\u00ed doba oblouku (m\u00e9n\u011b ne\u017e 8 ms) ve srovn\u00e1n\u00ed s pr\u016fmyslov\u00fdmi pr\u016fm\u011bry 10-15 ms.<\/li>\n<li>Vy\u0161\u0161\u00ed maxim\u00e1ln\u00ed jmenovit\u00e9 nap\u011bt\u00ed (1200 V DC) ne\u017e u standardn\u00edch izol\u00e1tor\u016f (obvykle omezeno na 1000 V DC).<\/li>\n<li>Vynikaj\u00edc\u00ed impulzn\u00ed v\u00fddr\u017en\u00e9 nap\u011bt\u00ed 8,0 kV pro lep\u0161\u00ed ochranu proti p\u0159ep\u011bt\u00ed<\/li>\n<\/ul>\n<h3>Zv\u00fd\u0161en\u00e1 odolnost<\/h3>\n<ul>\n<li>18 000 mechanick\u00fdch operac\u00ed je v\u00edce ne\u017e typick\u00fdch 10 000-15 000 operac\u00ed u konkuren\u010dn\u00edch v\u00fdrobk\u016f.<\/li>\n<li>2 000 elektrick\u00fdch operac\u00ed p\u0159ekon\u00e1v\u00e1 b\u011b\u017en\u00fdch 1 000 a\u017e 1 500 operac\u00ed standardn\u00edch izol\u00e1tor\u016f.<\/li>\n<li>Vy\u0161\u0161\u00ed zkratov\u00e1 odolnost zaji\u0161\u0165uje lep\u0161\u00ed ochranu p\u0159i poruch\u00e1ch.<\/li>\n<\/ul>\n<h3>Flexibilita instalace<\/h3>\n<ul>\n<li>Nepolarizovan\u00e1 konstrukce eliminuje chyby v p\u0159ipojen\u00ed a zjednodu\u0161uje instalaci.<\/li>\n<li>R\u016fzn\u00e9 proudov\u00e9 hodnoty (16A, 25A, 32A) umo\u017e\u0148uj\u00ed p\u0159izp\u016fsobit se r\u016fzn\u00fdm velikostem syst\u00e9m\u016f.<\/li>\n<li>Kompatibilita s r\u016fzn\u00fdmi \u00farovn\u011bmi nap\u011bt\u00ed v r\u016fzn\u00fdch konfigurac\u00edch sol\u00e1rn\u00edch soustav<\/li>\n<\/ul>\n<h2>Aplikace v r\u016fzn\u00fdch typech sol\u00e1rn\u00edch syst\u00e9m\u016f<\/h2>\n<h3>Instalace sol\u00e1rn\u00edch panel\u016f v obytn\u00fdch domech<\/h3>\n<p>Majitel\u016fm dom\u016f, kte\u0159\u00ed investuj\u00ed do sol\u00e1rn\u00ed energie, poskytuj\u00ed modely VOPV16-NL1 a VOPV25-NL1 ide\u00e1ln\u00ed ochranu pro typick\u00e9 obytn\u00e9 syst\u00e9my. Tyto odpojova\u010de zaji\u0161\u0165uj\u00ed bezpe\u010dn\u00e9 odpojen\u00ed p\u0159i \u00fadr\u017eb\u011b a nouzov\u00fdch situac\u00edch, \u010d\u00edm\u017e chr\u00e1n\u00ed investici i bezpe\u010dnost dom\u00e1cnosti. D\u00edky kompaktn\u00edmu proveden\u00ed a mo\u017enosti mont\u00e1\u017ee na li\u0161tu DIN jsou ide\u00e1ln\u00ed pro integraci do bytov\u00fdch rozv\u00e1d\u011b\u010d\u016f.<\/p>\n<h3>Komer\u010dn\u00ed fotovoltaick\u00e9 syst\u00e9my<\/h3>\n<p>Komer\u010dn\u00ed sol\u00e1rn\u00ed za\u0159\u00edzen\u00ed vyu\u017e\u00edvaj\u00ed vy\u0161\u0161\u00ed proudovou kapacitu modelu VOPV32-NL1. P\u0159i v\u00edce \u0159et\u011bzc\u00edch, kter\u00e9 jsou v komer\u010dn\u00edch instalac\u00edch b\u011b\u017en\u00e9, nab\u00edz\u00ed 4p\u00f3lov\u00e1 konfigurace rozs\u00e1hl\u00e9 mo\u017enosti izolace. Prodlou\u017een\u00e1 mechanick\u00e1 a elektrick\u00e1 odolnost zaji\u0161\u0165uje minim\u00e1ln\u00ed po\u017eadavky na \u00fadr\u017ebu a maxim\u00e1ln\u00ed dobu provozuschopnosti syst\u00e9mu, co\u017e jsou kritick\u00e9 faktory pro obchodn\u00ed provoz.<\/p>\n<h3>Sol\u00e1rn\u00ed \u0159e\u0161en\u00ed mimo s\u00ed\u0165<\/h3>\n<p>V aplikac\u00edch mimo s\u00ed\u0165, kde je nejd\u016fle\u017eit\u011bj\u0161\u00ed spolehlivost, poskytuje \u0159ada VOPV NL1 nezbytnou ochranu mezi sol\u00e1rn\u00edmi panely, bateriemi a st\u0159\u00edda\u010di. Nepolarizovan\u00e1 konstrukce je obzvl\u00e1\u0161t\u011b cenn\u00e1 ve vzd\u00e1len\u00fdch instalac\u00edch, kde nemus\u00ed b\u00fdt snadno dostupn\u00ed specializovan\u00ed technici, co\u017e sni\u017euje mo\u017en\u00e9 chyby p\u0159i instalaci.<\/p>\n<h2>\u00dadr\u017eba a \u017eivotnost<\/h2>\n<p>\u0158ada VOPV NL1 je navr\u017eena pro minim\u00e1ln\u00ed n\u00e1roky na \u00fadr\u017ebu po celou dobu sv\u00e9 provozn\u00ed \u017eivotnosti. Pro zaji\u0161t\u011bn\u00ed optim\u00e1ln\u00edho v\u00fdkonu a bezpe\u010dnosti v\u0161ak doporu\u010dujeme:<\/p>\n<ul>\n<li>Pravideln\u00e9 vizu\u00e1ln\u00ed kontroly na zn\u00e1mky opot\u0159eben\u00ed nebo po\u0161kozen\u00ed.<\/li>\n<li>Ka\u017edoro\u010dn\u00ed testov\u00e1n\u00ed funk\u010dnosti izolace<\/li>\n<li>Kontrola t\u011bsnosti svorek a p\u0159\u00edznak\u016f p\u0159eh\u0159\u00e1t\u00ed<\/li>\n<li>Ov\u011b\u0159en\u00ed stavu mont\u00e1\u017ee a krytu<\/li>\n<li>dokumentov\u00e1n\u00ed v\u0161ech \u010dinnost\u00ed \u00fadr\u017eby pro \u00fa\u010dely z\u00e1ruky a dodr\u017eov\u00e1n\u00ed p\u0159edpis\u016f.<\/li>\n<\/ul>\n<h2>Z\u00e1ruka a podpora<\/h2>\n<p>Ve spole\u010dnosti VIOX si stoj\u00edme za kvalitou a spolehlivost\u00ed na\u0161ich v\u00fdrobk\u016f. Na sp\u00edna\u010de VOPV DC Isolator Switch \u0159ady NL1 se vztahuje rozs\u00e1hl\u00e1 z\u00e1ruka a technick\u00e1 podpora:<\/p>\n<ul>\n<li>5let\u00e1 z\u00e1ruka v\u00fdrobce na vady materi\u00e1lu a zpracov\u00e1n\u00ed<\/li>\n<li>Technick\u00e9 konzultace pro n\u00e1vrh syst\u00e9mu a v\u00fdb\u011br produktu<\/li>\n<li>Poradenstv\u00ed p\u0159i instalaci a \u0159e\u0161en\u00ed probl\u00e9m\u016f<\/li>\n<li>Podpora dokumentace pro dodr\u017eov\u00e1n\u00ed p\u0159edpis\u016f<\/li>\n<li>Rychl\u00e1 reakce na reklamace a dotazy k produkt\u016fm<\/li>\n<\/ul>\n<h2>Z\u00e1v\u011br: Nejlep\u0161\u00ed volba pro ochranu fotovoltaick\u00fdch syst\u00e9m\u016f<\/h2>\n<p>Izol\u00e1torov\u00e9 sp\u00edna\u010de VOPV \u0159ady NL1 p\u0159edstavuj\u00ed ide\u00e1ln\u00ed rovnov\u00e1hu mezi bezpe\u010dnost\u00ed, spolehlivost\u00ed a v\u00fdkonem pro fotovoltaick\u00e9 aplikace. D\u00edky vynikaj\u00edc\u00edm elektrick\u00fdm vlastnostem, flexibiln\u00edm mo\u017enostem instalace a v\u00fdjime\u010dn\u00e9 odolnosti poskytuj\u00ed tyto odd\u011blovac\u00ed sp\u00edna\u010de nezbytnou ochranu investic do sol\u00e1rn\u00ed energie. V\u00fdb\u011brem \u0159ady NL1 pro sv\u016fj fotovoltaick\u00fd syst\u00e9m zajist\u00edte soulad s mezin\u00e1rodn\u00edmi bezpe\u010dnostn\u00edmi normami a z\u00e1rove\u0148 budete t\u011b\u017eit z p\u0159edn\u00ed kvality a v\u00fdkonu v oboru.<\/p>\n<p>Chcete-li z\u00edskat dal\u0161\u00ed informace o sp\u00edna\u010di VOPV DC s izol\u00e1torem \u0159ady NL1 nebo prodiskutovat sv\u00e9 konkr\u00e9tn\u00ed po\u017eadavky na aplikaci, kontaktujte n\u00e1\u0161 technick\u00fd t\u00fdm je\u0161t\u011b dnes. Na\u0161i odborn\u00edci na sol\u00e1rn\u00ed energii jsou p\u0159ipraveni pomoci v\u00e1m s v\u00fdb\u011brem optim\u00e1ln\u00edho \u0159e\u0161en\u00ed izol\u00e1toru pro v\u00e1\u0161 fotovoltaick\u00fd syst\u00e9m a zajistit tak maxim\u00e1ln\u00ed bezpe\u010dnost a v\u00fdkon po mnoho let.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"markdown\">\n<p>Zajist\u011bte sol\u00e1rn\u00ed bezpe\u010dnost pomoc\u00ed stejnosm\u011brn\u00fdch izol\u00e1torov\u00fdch sp\u00edna\u010d\u016f VIOX VOPV NL1. Navr\u017eeno pro <strong>1-20kW<\/strong> Fotovoltaick\u00e9 syst\u00e9my nab\u00edzej\u00ed <strong>1200V<\/strong> izolace a rychl\u00e1 <strong>&lt;8ms \u0159\u00edzen\u00ed oblouku<\/strong>. Nepolarizovan\u00e9 pro snadnou instalaci, mo\u017enost mont\u00e1\u017ee na DIN, certifikov\u00e1no podle IEC\/AS. K dispozici v proveden\u00ed 16A, 25A, 32A.<\/p>\n<\/div>","protected":false},"featured_media":14983,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[134],"product_tag":[],"class_list":{"0":"post-14987","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-photovoltaic-dc-isolator-switch","7":"desktop-align-left","8":"tablet-align-left","9":"mobile-align-left","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product\/14987","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/comments?post=14987"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media\/14983"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media?parent=14987"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product_brand?post=14987"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product_cat?post=14987"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product_tag?post=14987"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}