{"id":14972,"date":"2025-03-31T14:28:26","date_gmt":"2025-03-31T06:28:26","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=14972"},"modified":"2025-03-31T16:37:27","modified_gmt":"2025-03-31T08:37:27","slug":"vopv-dc-isolator-switch-l1-series","status":"publish","type":"product","link":"https:\/\/test.viox.com\/cs\/produkt\/vopv-dc-isolator-switch-l1-series\/","title":{"rendered":"Izol\u00e1torov\u00fd sp\u00edna\u010d VOPV DC \u0159ady L1"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>\u00davod do sp\u00edna\u010d\u016f DC izol\u00e1tor\u016f<\/h2>\n<p>Na rychle se rozv\u00edjej\u00edc\u00edm trhu se sol\u00e1rn\u00ed energi\u00ed z\u016fst\u00e1vaj\u00ed bezpe\u010dnost a spolehlivost prvo\u0159ad\u00fdm probl\u00e9mem jak pro reziden\u010dn\u00ed, tak pro komer\u010dn\u00ed instalace. Izol\u00e1torov\u00e9 sp\u00edna\u010de VOPV DC \u0159ady L1 p\u0159edstavuj\u00ed v\u00fdznamn\u00fd pokrok v technologii ochrany fotovoltaick\u00fdch syst\u00e9m\u016f a nab\u00edzej\u00ed vynikaj\u00edc\u00ed izola\u010dn\u00ed schopnosti speci\u00e1ln\u011b navr\u017een\u00e9 pro sol\u00e1rn\u00ed aplikace. Tento prvot\u0159\u00eddn\u00ed odd\u011blovac\u00ed sp\u00edna\u010d slou\u017e\u00ed jako kritick\u00e1 bezpe\u010dnostn\u00ed sou\u010d\u00e1st ka\u017ed\u00e9ho fotovoltaick\u00e9ho syst\u00e9mu a zaji\u0161\u0165uje spolehlivou elektrickou izolaci mezi sol\u00e1rn\u00edmi panely a st\u0159\u00edda\u010di pro zaji\u0161t\u011bn\u00ed ochrany syst\u00e9mu i bezpe\u010dnosti person\u00e1lu p\u0159i \u00fadr\u017eb\u011b nebo v nouzov\u00fdch situac\u00edch.<\/p>\n<h2>Co je to stejnosm\u011brn\u00fd izola\u010dn\u00ed sp\u00edna\u010d?<\/h2>\n<p>Odpojova\u010d stejnosm\u011brn\u00e9ho proudu je specializovan\u00e9 elektrick\u00e9 bezpe\u010dnostn\u00ed za\u0159\u00edzen\u00ed ur\u010den\u00e9 k \u00fapln\u00e9mu odpojen\u00ed toku stejnosm\u011brn\u00e9ho proudu ze sol\u00e1rn\u00edch panel\u016f do st\u0159\u00edda\u010de. Na rozd\u00edl od standardn\u00edch sp\u00edna\u010d\u016f st\u0159\u00eddav\u00e9ho proudu jsou stejnosm\u011brn\u00e9 odd\u011blovac\u00ed sp\u00edna\u010de speci\u00e1ln\u011b navr\u017eeny tak, aby zvl\u00e1daly jedine\u010dn\u00e9 vlastnosti stejnosm\u011brn\u00e9ho proudu, v\u010detn\u011b mo\u017enosti vzniku nebezpe\u010dn\u00e9ho oblouku stejnosm\u011brn\u00e9ho proudu. \u0158ada VOPV L1 byla pe\u010dliv\u011b navr\u017eena tak, aby tyto probl\u00e9my \u0159e\u0161ila, a nab\u00edz\u00ed bezpe\u010dn\u00e9 a spolehliv\u00e9 odd\u011blen\u00ed pro fotovoltaick\u00e9 instalace o v\u00fdkonu od 1 do 20 kilowatt\u016f.<\/p>\n<h2>P\u0159ehled stejnosm\u011brn\u00fdch sp\u00edna\u010d\u016f VOPV \u0159ady L1<\/h2>\n<p>Izola\u010dn\u00ed sp\u00edna\u010d stejnosm\u011brn\u00e9ho proudu \u0159ady L1 je \u0161pi\u010dkov\u00e9 bezpe\u010dnostn\u00ed \u0159e\u0161en\u00ed pro obytn\u00e9 nebo komer\u010dn\u00ed fotovoltaick\u00e9 syst\u00e9my o v\u00fdkonu 1-20 KW. Tento odd\u011blovac\u00ed sp\u00edna\u010d, strategicky um\u00edst\u011bn\u00fd mezi fotovoltaick\u00e9 moduly a st\u0159\u00edda\u010de, poskytuje z\u00e1kladn\u00ed ochranu p\u0159ed elektrick\u00fdm nebezpe\u010d\u00edm a z\u00e1rove\u0148 zaji\u0161\u0165uje optim\u00e1ln\u00ed v\u00fdkon syst\u00e9mu. D\u00edky dob\u011b oblouku krat\u0161\u00ed ne\u017e 8 ms \u0159ada L1 v\u00fdrazn\u011b sni\u017euje riziko po\u017e\u00e1ru elektrick\u00e9ho proudu a po\u0161kozen\u00ed syst\u00e9mu, tak\u017ee va\u0161e sol\u00e1rn\u00ed instalace je bezpe\u010dn\u011bj\u0161\u00ed ne\u017e kdykoli p\u0159edt\u00edm.<\/p>\n<p>Na\u0161e \u0159ada VOPV DC izol\u00e1torov\u00fdch sp\u00edna\u010d\u016f L1 je navr\u017eena pro dokonalost a je vyr\u00e1b\u011bna z komponent\u016f optim\u00e1ln\u00ed kvality, kter\u00e9 zaji\u0161\u0165uj\u00ed v\u00fdjime\u010dnou stabilitu a prodlou\u017eenou \u017eivotnost. S maxim\u00e1ln\u00edm jmenovit\u00fdm nap\u011bt\u00edm a\u017e 1200 V DC si tento odd\u011blovac\u00ed sp\u00edna\u010d udr\u017euje bezpe\u010dn\u00e9 prvenstv\u00ed mezi podobn\u00fdmi v\u00fdrobky na trhu a poskytuje nekompromisn\u00ed ochranu va\u0161\u00ed cenn\u00e9 sol\u00e1rn\u00ed investice.<\/p>\n<h2>Kl\u00ed\u010dov\u00e9 vlastnosti a v\u00fdhody stejnosm\u011brn\u00fdch sp\u00edna\u010d\u016f VOPV \u0159ady L1<\/h2>\n<h3>V\u00fdjime\u010dn\u00e9 bezpe\u010dnostn\u00ed funkce<\/h3>\n<ul>\n<li><strong>Rychl\u00e9 zh\u00e1\u0161en\u00ed oblouku:<\/strong> D\u00edky dob\u011b oblouku krat\u0161\u00ed ne\u017e 8 ms minimalizuje \u0159ada VOPV L1 riziko po\u017e\u00e1ru a po\u0161kozen\u00ed syst\u00e9mu.<\/li>\n<li><strong>Uzamykateln\u00e1 rukoje\u0165:<\/strong> Rukoje\u0165 lze bezpe\u010dn\u011b zablokovat v poloze \"OFF\", co\u017e zabra\u0148uje n\u00e1hodn\u00e9mu op\u011btovn\u00e9mu p\u0159ipojen\u00ed b\u011bhem \u00fadr\u017eby nebo v nouzov\u00fdch situac\u00edch.<\/li>\n<li><strong>Stupe\u0148 kryt\u00ed IP20:<\/strong> Zaji\u0161\u0165uje ochranu p\u0159ed pevn\u00fdmi p\u0159edm\u011bty v\u011bt\u0161\u00edmi ne\u017e 12 mm a poskytuje dodate\u010dnou bezpe\u010dnostn\u00ed bari\u00e9ru.<\/li>\n<li><strong>Vysok\u00e9 izola\u010dn\u00ed nap\u011bt\u00ed:<\/strong> Jmenovit\u00e9 izola\u010dn\u00ed nap\u011bt\u00ed 1200 V DC zaji\u0161\u0165uje \u00fapln\u00e9 elektrick\u00e9 odd\u011blen\u00ed vstupn\u00edch a v\u00fdstupn\u00edch obvod\u016f.<\/li>\n<\/ul>\n<h3>V\u0161estrann\u00e9 mo\u017enosti konfigurace<\/h3>\n<ul>\n<li><strong>V\u00edcen\u00e1sobn\u00e9 hodnocen\u00ed proudu:<\/strong> K dispozici jsou varianty 16A, 25A a 32A (VOPV16-L1, VOPV25-L1, VOPV32-L1), kter\u00e9 vyhovuj\u00ed r\u016fzn\u00fdm syst\u00e9mov\u00fdm po\u017eadavk\u016fm.<\/li>\n<li><strong>Flexibiln\u00ed konfigurace p\u00f3l\u016f:<\/strong> K dispozici jsou 2p\u00f3lov\u00e9 a 4p\u00f3lov\u00e9 varianty, vhodn\u00e9 pro konfigurace s jedn\u00edm i dv\u011bma \u0159et\u011bzci.<\/li>\n<li><strong>\u0160irok\u00fd rozsah nap\u011bt\u00ed:<\/strong> Pracuje na r\u016fzn\u00fdch nap\u011b\u0165ov\u00fdch \u00farovn\u00edch v\u010detn\u011b 300 V, 600 V, 800 V, 1000 V a 1200 V DC.<\/li>\n<\/ul>\n<h3>Instalace a praktick\u00e9 v\u00fdhody<\/h3>\n<ul>\n<li><strong>Mont\u00e1\u017e na li\u0161tu DIN:<\/strong> Snadn\u00e1 instalace na standardn\u00ed li\u0161ty DIN \u0161et\u0159\u00ed \u010das a zaji\u0161\u0165uje bezpe\u010dn\u00e9 um\u00edst\u011bn\u00ed.<\/li>\n<li><strong>\u017d\u00e1dn\u00e9 omezen\u00ed polarity:<\/strong> Polarity \"+\" a \"-\" lze zam\u011bnit, co\u017e zjednodu\u0161uje instalaci a sni\u017euje po\u010det mo\u017en\u00fdch chyb.<\/li>\n<li><strong>Kompaktn\u00ed design:<\/strong> Prostorov\u011b \u00fasporn\u00e9 rozm\u011bry umo\u017e\u0148uj\u00ed instalaci ve st\u00edsn\u011bn\u00fdch prostorech bez omezen\u00ed funk\u010dnosti.<\/li>\n<\/ul>\n<h2>Technick\u00e9 specifikace: VOPV DC Izol\u00e1torov\u00fd sp\u00edna\u010d \u0159ady L1<\/h2>\n<h3>Dodr\u017eov\u00e1n\u00ed p\u0159edpis\u016f a certifikace<\/h3>\n<p>Izol\u00e1torov\u00e9 sp\u00edna\u010de stejnosm\u011brn\u00e9ho proudu \u0159ady VOPV L1 jsou vyr\u00e1b\u011bny v p\u0159\u00edsn\u00e9m souladu s mezin\u00e1rodn\u00edmi normami:<\/p>\n<ul>\n<li><strong>Dodr\u017eov\u00e1n\u00ed standard\u016f:<\/strong> IEC60947-3, AS60947.3<\/li>\n<li><strong>Kategorie vyu\u017eit\u00ed:<\/strong> DC-PV2, DC-PV1, DC-21B<\/li>\n<\/ul>\n<h3>Elektrick\u00e9 charakteristiky<\/h3>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th>Parametr<\/th>\n<th>Specifikace<\/th>\n<\/tr>\n<tr>\n<td>Dostupn\u00e9 modely<\/td>\n<td>VOPV16-L1, VOPV25-L1, VOPV32-L1<\/td>\n<\/tr>\n<tr>\n<td>Konfigurace p\u00f3l\u016f<\/td>\n<td>4P (4 p\u00f3ly)<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00e1 frekvence<\/td>\n<td>DC<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00e9 provozn\u00ed nap\u011bt\u00ed (Ue)<\/td>\n<td>300 V, 600 V, 800 V, 1000 V, 1200 V<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00e9 izola\u010dn\u00ed nap\u011bt\u00ed (Ui)<\/td>\n<td>1200V<\/td>\n<\/tr>\n<tr>\n<td>Konven\u010dn\u00ed uzav\u0159en\u00fd tepeln\u00fd proud<\/td>\n<td>Stejn\u011b jako Ie<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00fd kr\u00e1tkodob\u00fd v\u00fddr\u017en\u00fd proud (Icw)<\/td>\n<td>1kA, 1s<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00e9 impulzn\u00ed v\u00fddr\u017en\u00e9 nap\u011bt\u00ed (Uimp)<\/td>\n<td>8,0 kV<\/td>\n<\/tr>\n<tr>\n<td>Kategorie p\u0159ep\u011bt\u00ed<\/td>\n<td>II<\/td>\n<\/tr>\n<tr>\n<td>Vhodnost izolace<\/td>\n<td>ANO<\/td>\n<\/tr>\n<tr>\n<td>Polarita<\/td>\n<td>\u017d\u00e1dn\u00e1 polarita, polaritu \"+\" a \"-\" lze zam\u011bnit.<\/td>\n<\/tr>\n<tr>\n<td>Ochrana proti vniknut\u00ed (t\u011blo sp\u00edna\u010de)<\/td>\n<td>IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Trvanlivost a spolehlivost<\/h3>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th>Parametr<\/th>\n<th>Hodnota<\/th>\n<\/tr>\n<tr>\n<td>Mechanick\u00e1 odolnost<\/td>\n<td>18 000 operac\u00ed<\/td>\n<\/tr>\n<tr>\n<td>Elektrick\u00e1 odolnost<\/td>\n<td>2 000 operac\u00ed<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Rozm\u011bry stejnosm\u011brn\u00e9ho izol\u00e1toru VOPV \u0159ady L1<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-14975\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L1-Series-Dimension.webp\" alt=\"VOPV DC Isolator Switch L1 Series Dimension\" width=\"728\" height=\"502\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L1-Series-Dimension.webp 728w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L1-Series-Dimension-300x207.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L1-Series-Dimension-18x12.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L1-Series-Dimension-600x414.webp 600w\" sizes=\"(max-width: 728px) 100vw, 728px\" \/><\/p>\n<h2>Sch\u00e9ma zapojen\u00ed kontakt\u016f stejnosm\u011brn\u00e9ho sp\u00edna\u010de VOPV \u0159ady L1<\/h2>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14974\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L1-Series-contact-wiring-diagram.webp\" alt=\"VOPV DC Isolator Switch L1 Series contact wiring diagram\" width=\"576\" height=\"500\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L1-Series-contact-wiring-diagram.webp 576w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L1-Series-contact-wiring-diagram-300x260.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L1-Series-contact-wiring-diagram-14x12.webp 14w\" sizes=\"(max-width: 576px) 100vw, 576px\" \/><\/p>\n<h2>Aplikace stejnosm\u011brn\u00e9ho izol\u00e1toru VOPV \u0159ady L1<\/h2>\n<h3>Instalace sol\u00e1rn\u00edch panel\u016f v obytn\u00fdch domech<\/h3>\n<p>\u0158ada VOPV L1 se ide\u00e1ln\u011b hod\u00ed pro sol\u00e1rn\u00ed syst\u00e9my pro dom\u00e1cnosti od 1 kW do 20 kW. V dom\u00e1c\u00edch instalac\u00edch poskytuje tento odd\u011blovac\u00ed sp\u00edna\u010d z\u00e1kladn\u00ed bezpe\u010dnostn\u00ed funkce, kter\u00e9 umo\u017e\u0148uj\u00ed majitel\u016fm dom\u016f rychle odpojit sol\u00e1rn\u00ed panely od st\u0159\u00edda\u010de b\u011bhem \u00fadr\u017eby, nouzov\u00fdch situac\u00ed nebo p\u0159i nep\u0159\u00edzniv\u00e9m po\u010das\u00ed. Funkce uzamykateln\u00e9 rukojeti zaji\u0161\u0165uje, \u017ee d\u011bti nebo neopr\u00e1vn\u011bn\u00e9 osoby nemohou syst\u00e9m ne\u00famysln\u011b znovu p\u0159ipojit, co\u017e majitel\u016fm dom\u016f poskytuje klid.<\/p>\n<h3>Komer\u010dn\u00ed fotovoltaick\u00e9 syst\u00e9my<\/h3>\n<p>Pro komer\u010dn\u00ed instalace nab\u00edz\u00ed \u0159ada VOPV L1 robustn\u00ed v\u00fdkon a spolehlivost pot\u0159ebnou v profesion\u00e1ln\u00edm prost\u0159ed\u00ed. Schopnost odd\u011blovac\u00edho sp\u00edna\u010de pracovat s nap\u011bt\u00edm a\u017e 1200 V DC jej \u010din\u00ed vhodn\u00fdm pro v\u011bt\u0161\u00ed komer\u010dn\u00ed syst\u00e9my, zat\u00edmco jeho soulad s mezin\u00e1rodn\u00edmi normami zaji\u0161\u0165uje, \u017ee spl\u0148uje p\u0159\u00edsn\u00e9 po\u017eadavky, kter\u00e9 jsou \u010dasto specifikov\u00e1ny v komer\u010dn\u00edch sol\u00e1rn\u00edch projektech. Mo\u017enost mont\u00e1\u017ee na li\u0161tu DIN usnad\u0148uje integraci do st\u00e1vaj\u00edc\u00ed elektrick\u00e9 infrastruktury, \u010d\u00edm\u017e \u0161et\u0159\u00ed cenn\u00fd \u010das a zdroje na instalaci.<\/p>\n<h3>Sol\u00e1rn\u00ed \u0159e\u0161en\u00ed mimo s\u00ed\u0165<\/h3>\n<p>V sol\u00e1rn\u00edch aplikac\u00edch mimo s\u00ed\u0165, kde je spolehlivost syst\u00e9mu obzvl\u00e1\u0161t\u011b d\u016fle\u017eit\u00e1, poskytuje \u0159ada VOPV L1 spolehliv\u00e9 izola\u010dn\u00ed schopnosti. V\u00fdjime\u010dn\u00e1 odolnost sp\u00edna\u010de s 18 000 mechanick\u00fdmi a 2 000 elektrick\u00fdmi operacemi zaji\u0161\u0165uje dlouhodobou funk\u010dnost i na odlehl\u00fdch m\u00edstech, kde m\u016f\u017ee b\u00fdt n\u00e1ro\u010dn\u00e1 \u00fadr\u017eba. D\u00edky schopnosti pracovat s r\u016fzn\u00fdmi \u00farovn\u011bmi nap\u011bt\u00ed je tento odd\u011blovac\u00ed sp\u00edna\u010d p\u0159izp\u016fsobiteln\u00fd r\u016fzn\u00fdm konfigurac\u00edm syst\u00e9m\u016f mimo s\u00ed\u0165.<\/p>\n<h2>Bezpe\u010dnostn\u00ed v\u00fdhody stejnosm\u011brn\u00e9ho sp\u00edna\u010de VOPV<\/h2>\n<h3>Ochrana proti obloukov\u00fdm poruch\u00e1m stejnosm\u011brn\u00e9ho proudu<\/h3>\n<p>Jedn\u00edm z nejz\u00e1va\u017en\u011bj\u0161\u00edch nebezpe\u010d\u00ed v elektrick\u00fdch syst\u00e9mech stejnosm\u011brn\u00e9ho proudu jsou obloukov\u00e9 poruchy, kter\u00e9 mohou zp\u016fsobit v\u00e1\u017en\u00e9 po\u017e\u00e1ry a \u0161kody. Odd\u011blovac\u00ed sp\u00edna\u010d \u0159ady VOPV L1 \u0159e\u0161\u00ed tento probl\u00e9m d\u00edky schopnosti rychl\u00e9ho zh\u00e1\u0161en\u00ed oblouku. D\u00edky dob\u011b zh\u00e1\u0161en\u00ed oblouku krat\u0161\u00ed ne\u017e 8 ms rychle p\u0159eru\u0161\u00ed potenci\u00e1ln\u00ed obloukov\u00e9 poruchy, \u010d\u00edm\u017e v\u00fdrazn\u011b sni\u017euje riziko po\u017e\u00e1ru a zvy\u0161uje celkovou bezpe\u010dnost syst\u00e9mu.<\/p>\n<h3>Bezpe\u010dn\u00e1 izolace b\u011bhem \u00fadr\u017eby<\/h3>\n<p>\u00dadr\u017eba sol\u00e1rn\u00edch syst\u00e9m\u016f vy\u017eaduje \u00faplnou elektrickou izolaci, aby byla zaji\u0161t\u011bna bezpe\u010dnost technik\u016f. Izola\u010dn\u00ed sp\u00edna\u010d VOPV zaji\u0161\u0165uje spolehliv\u00e9 odpojen\u00ed stejnosm\u011brn\u00e9ho obvodu a vytv\u00e1\u0159\u00ed tak bezpe\u010dn\u00e9 pracovn\u00ed prost\u0159ed\u00ed. Uzamykateln\u00e1 vyp\u00ednac\u00ed poloha zabra\u0148uje n\u00e1hodn\u00e9mu nebo neopr\u00e1vn\u011bn\u00e9mu op\u011btovn\u00e9mu p\u0159ipojen\u00ed b\u011bhem postup\u016f \u00fadr\u017eby, co\u017e pracovn\u00edk\u016fm \u00fadr\u017eby dod\u00e1v\u00e1 dal\u0161\u00ed \u00farove\u0148 bezpe\u010dnosti.<\/p>\n<h3>Mo\u017enost nouzov\u00e9ho vypnut\u00ed<\/h3>\n<p>V nouzov\u00fdch situac\u00edch m\u016f\u017ee b\u00fdt nutn\u00e9 rychl\u00e9 vypnut\u00ed sol\u00e1rn\u00edho syst\u00e9mu. \u0158ada VOPV L1 umo\u017e\u0148uje rychl\u00e9 a \u00fapln\u00e9 odpojen\u00ed fotovoltaick\u00e9ho pole od zbytku syst\u00e9mu, co\u017e pom\u00e1h\u00e1 p\u0159edch\u00e1zet potenci\u00e1ln\u00edm \u0161kod\u00e1m nebo bezpe\u010dnostn\u00edm rizik\u016fm p\u0159i po\u017e\u00e1rech, elektrick\u00fdch poruch\u00e1ch nebo extr\u00e9mn\u00edch pov\u011btrnostn\u00edch podm\u00ednk\u00e1ch.<\/p>\n<h2>Pr\u016fvodce instalac\u00ed: VOPV stejnosm\u011brn\u00fd izol\u00e1tor \u0159ady L1<\/h2>\n<h3>Doporu\u010den\u00e9 m\u00edsto instalace<\/h3>\n<p>Izola\u010dn\u00ed sp\u00edna\u010d VOPV DC by m\u011bl b\u00fdt instalov\u00e1n mezi fotovoltaick\u00e9 moduly a st\u0159\u00edda\u010d na snadno p\u0159\u00edstupn\u00e9m m\u00edst\u011b pro nouzov\u00e9 ovl\u00e1d\u00e1n\u00ed. Pro optim\u00e1ln\u00ed v\u00fdkon a bezpe\u010dnost by m\u011bl b\u00fdt sp\u00edna\u010d instalov\u00e1n na m\u00edst\u011b chr\u00e1n\u011bn\u00e9m p\u0159ed pov\u011btrnostn\u00edmi vlivy nebo ve vhodn\u00e9m krytu, pokud je vystaven venkovn\u00edm podm\u00ednk\u00e1m.<\/p>\n<h3>Postup mont\u00e1\u017ee<\/h3>\n<p>\u0158ada VOPV L1 je vybavena pohodlnou mont\u00e1\u017e\u00ed na li\u0161tu DIN, kter\u00e1 umo\u017e\u0148uje jednoduchou a bezpe\u010dnou instalaci. Sp\u00edna\u010d by m\u011bl b\u00fdt pevn\u011b p\u0159ipevn\u011bn na standardn\u00ed 35mm li\u0161tu DIN, aby nemohlo doj\u00edt k jeho n\u00e1hodn\u00e9mu vysunut\u00ed. Po mont\u00e1\u017ei zkontrolujte, zda sp\u00edna\u010d funguje bez probl\u00e9m\u016f a zda spr\u00e1vn\u011b funguje blokovac\u00ed mechanismus.<\/p>\n<h3>Pokyny k zapojen\u00ed<\/h3>\n<p>P\u0159i p\u0159ipojov\u00e1n\u00ed sp\u00edna\u010de VOPV DC Isolator Switch se \u0159i\u010fte sch\u00e9matem zapojen\u00ed kontakt\u016f dodan\u00fdm s v\u00fdrobkem. Sp\u00edna\u010d umo\u017e\u0148uje 2p\u00f3lov\u00e9 i 4p\u00f3lov\u00e9 konfigurace, vhodn\u00e9 pro jedno- nebo dvou\u0159et\u011bzcov\u00e9 syst\u00e9my. Vzhledem k tomu, \u017ee sp\u00edna\u010d nem\u00e1 \u017e\u00e1dn\u00e9 omezen\u00ed polarity, lze p\u0159ipojen\u00ed \"+\" a \"-\" zam\u011bnit, co\u017e zjednodu\u0161uje proces instalace.<\/p>\n<h2>\u00dadr\u017eba a p\u00e9\u010de<\/h2>\n<h3>Doporu\u010den\u00ed pro pravideln\u00e9 kontroly<\/h3>\n<p>Abyste zajistili trvalou optim\u00e1ln\u00ed funk\u010dnost va\u0161eho stejnosm\u011brn\u00e9ho izola\u010dn\u00edho sp\u00edna\u010de VOPV, doporu\u010dujeme prov\u00e1d\u011bt pravideln\u00e9 vizu\u00e1ln\u00ed kontroly. Zkontrolujte, zda nejsou patrn\u00e9 zn\u00e1mky fyzick\u00e9ho po\u0161kozen\u00ed, uvoln\u011bn\u00fdch spoj\u016f nebo koroze. Zkontrolujte, zda se rukoje\u0165 sp\u00edna\u010de ovl\u00e1d\u00e1 hladce a zda spr\u00e1vn\u011b funguje blokovac\u00ed mechanismus. Tyto kontroly se doporu\u010duje prov\u00e1d\u011bt alespo\u0148 jednou za \u0161est m\u011bs\u00edc\u016f, v n\u00e1ro\u010dn\u00fdch podm\u00ednk\u00e1ch prost\u0159ed\u00ed i \u010dast\u011bji.<\/p>\n<h3>Testovac\u00ed postupy<\/h3>\n<p>Pravideln\u00e9 testov\u00e1n\u00ed funk\u010dnosti odpojova\u010de je nezbytn\u00e9 pro zachov\u00e1n\u00ed bezpe\u010dnosti syst\u00e9mu. Kdy\u017e je sol\u00e1rn\u00ed syst\u00e9m ve stavu n\u00edzk\u00e9 v\u00fdroby (brzy r\u00e1no nebo za zata\u017een\u00e9ho dne), sp\u00edna\u010d zapn\u011bte a ov\u011b\u0159te, zda \u00fasp\u011b\u0161n\u011b odpojuje fotovoltaick\u00e9 pole od st\u0159\u00edda\u010de. Ov\u011b\u0159te, \u017ee se st\u0159\u00edda\u010d vypne, kdy\u017e je sp\u00edna\u010d v poloze OFF, co\u017e sv\u011bd\u010d\u00ed o spr\u00e1vn\u00e9m odpojen\u00ed. Toto testov\u00e1n\u00ed by se m\u011blo prov\u00e1d\u011bt ka\u017edoro\u010dn\u011b v r\u00e1mci b\u011b\u017en\u00e9 \u00fadr\u017eby syst\u00e9mu.<\/p>\n<h3>\u0158e\u0161en\u00ed b\u011b\u017en\u00fdch probl\u00e9m\u016f<\/h3>\n<p>Pokud se setk\u00e1te s pot\u00ed\u017eemi p\u0159i ovl\u00e1d\u00e1n\u00ed sp\u00ednac\u00ed rukojeti, zkontrolujte, zda se na n\u00ed nenach\u00e1z\u00ed p\u0159ek\u00e1\u017eky nebo zn\u00e1mky mechanick\u00e9ho po\u0161kozen\u00ed. V p\u0159\u00edpad\u011b elektrick\u00fdch probl\u00e9m\u016f, jako je nap\u0159\u00edklad pokra\u010duj\u00edc\u00ed provoz m\u011bni\u010de p\u0159i vypnut\u00e9m sp\u00edna\u010di, zkontrolujte zapojen\u00ed kabel\u016f podle dodan\u00e9ho sch\u00e9matu. Pokud probl\u00e9my p\u0159etrv\u00e1vaj\u00ed, obra\u0165te se na kvalifikovan\u00e9ho sol\u00e1rn\u00edho technika, kter\u00fd provede odborn\u00e9 posouzen\u00ed a opravu.<\/p>\n<h2>Srovn\u00e1n\u00ed \u0159ady VOPV L1 s jin\u00fdmi izol\u00e1torov\u00fdmi sp\u00edna\u010di<\/h2>\n<h3>V\u00fdhody oproti standardn\u00edm izol\u00e1tor\u016fm st\u0159\u00eddav\u00e9ho proudu<\/h3>\n<p>Na rozd\u00edl od standardn\u00edch st\u0159\u00eddav\u00fdch odd\u011blovac\u00edch sp\u00edna\u010d\u016f je \u0159ada VOPV L1 navr\u017eena speci\u00e1ln\u011b pro stejnosm\u011brn\u00e9 aplikace, zejm\u00e9na pro fotovoltaick\u00e9 syst\u00e9my. Vyzna\u010duje se specializovan\u00fdmi schopnostmi zh\u00e1\u0161en\u00ed oblouku (doba zh\u00e1\u0161en\u00ed oblouku krat\u0161\u00ed ne\u017e 8 ms), kter\u00e9 \u0159e\u0161\u00ed jedine\u010dn\u00e9 probl\u00e9my spojen\u00e9 s p\u0159eru\u0161en\u00edm stejnosm\u011brn\u00e9ho proudu. Standardn\u00ed odpojova\u010de st\u0159\u00eddav\u00e9ho proudu tyto z\u00e1kladn\u00ed funkce postr\u00e1daj\u00ed, tak\u017ee jsou pro aplikace odpojov\u00e1n\u00ed stejnosm\u011brn\u00e9ho proudu nevhodn\u00e9 a potenci\u00e1ln\u011b nebezpe\u010dn\u00e9.<\/p>\n<h3>Konkuren\u010dn\u00ed v\u00fdhoda na trhu stejnosm\u011brn\u00fdch izol\u00e1tor\u016f<\/h3>\n<p>\u0158ada VOPV L1 vynik\u00e1 mezi stejnosm\u011brn\u00fdmi odpojova\u010di v\u00fdjime\u010dn\u00fdm jmenovit\u00fdm nap\u011bt\u00edm a\u017e 1200 V DC, kter\u00e9 p\u0159ekon\u00e1v\u00e1 mnoho konkuren\u010dn\u00edch v\u00fdrobk\u016f. Kombinace vysoce kvalitn\u00edch komponent, univerz\u00e1ln\u00edch mo\u017enost\u00ed konfigurace a shody s mezin\u00e1rodn\u00edmi normami ji stav\u00ed do pozice prvot\u0159\u00eddn\u00ed volby pro n\u00e1ro\u010dn\u00e9 instalat\u00e9ry a projektanty sol\u00e1rn\u00edch syst\u00e9m\u016f. Konstrukce bez polarity tak\u00e9 zjednodu\u0161uje instalaci ve srovn\u00e1n\u00ed s mnoha alternativami citliv\u00fdmi na polaritu.<\/p>\n<h2>Z\u00e1ruka a podpora<\/h2>\n<h3>Podrobnosti o z\u00e1ruce na produkt<\/h3>\n<p>Na stejnosm\u011brn\u00e9 sp\u00edna\u010de VOPV \u0159ady L1 je poskytov\u00e1na rozs\u00e1hl\u00e1 z\u00e1ruka, kter\u00e1 odr\u00e1\u017e\u00ed na\u0161i d\u016fv\u011bru v jejich kvalitu a trvanlivost. Na\u0161e standardn\u00ed z\u00e1ruka se vztahuje na v\u00fdrobn\u00ed vady a poruchy materi\u00e1lu za b\u011b\u017en\u00fdch provozn\u00edch podm\u00ednek. Konkr\u00e9tn\u00ed z\u00e1ru\u010dn\u00ed podm\u00ednky naleznete v z\u00e1ru\u010dn\u00ed dokumentaci p\u0159ilo\u017een\u00e9 k n\u00e1kupu nebo se obra\u0165te na n\u00e1\u0161 t\u00fdm z\u00e1kaznick\u00e9 podpory.<\/p>\n<h3>Slu\u017eby technick\u00e9 podpory<\/h3>\n<p>N\u00e1\u0161 specializovan\u00fd t\u00fdm technick\u00e9 podpory je v\u00e1m k dispozici v p\u0159\u00edpad\u011b jak\u00fdchkoli dotaz\u016f nebo probl\u00e9m\u016f t\u00fdkaj\u00edc\u00edch se \u0159ady VOPV L1. Na\u0161i odborn\u00edci poskytuj\u00ed rychlou a kvalifikovanou podporu, od pokyn\u016f pro instalaci a\u017e po pomoc p\u0159i \u0159e\u0161en\u00ed probl\u00e9m\u016f, aby zajistili va\u0161i plnou spokojenost s na\u0161imi v\u00fdrobky. Technickou podporu m\u016f\u017eete z\u00edskat prost\u0159ednictv\u00edm na\u0161\u00ed hork\u00e9 linky z\u00e1kaznick\u00e9ho servisu nebo e-mailem.<\/p>\n<h2>Z\u00e1v\u011br: Pro\u010d si vybrat stejnosm\u011brn\u00fd izol\u00e1tor VOPV \u0159ady L1?<\/h2>\n<p>Izol\u00e1torov\u00e9 sp\u00edna\u010de VOPV DC \u0159ady L1 p\u0159edstavuj\u00ed vrchol bezpe\u010dnosti a spolehlivosti v oblasti ochrany fotovoltaick\u00fdch syst\u00e9m\u016f. Tento \u0161pi\u010dkov\u00fd odd\u011blovac\u00ed sp\u00edna\u010d, navr\u017een\u00fd speci\u00e1ln\u011b pro sol\u00e1rn\u00ed aplikace od 1 do 20 KW, kombinuje pokro\u010dil\u00e9 bezpe\u010dnostn\u00ed funkce, univerz\u00e1ln\u00ed mo\u017enosti konfigurace a v\u00fdjime\u010dnou odolnost, aby poskytoval vynikaj\u00edc\u00ed v\u00fdkon v reziden\u010dn\u00edch i komer\u010dn\u00edch instalac\u00edch.<\/p>\n<p>D\u00edky schopnosti rychl\u00e9ho zh\u00e1\u0161en\u00ed oblouku, uzamykateln\u00e9 rukojeti a souladu s mezin\u00e1rodn\u00edmi normami poskytuje \u0159ada VOPV L1 klid majitel\u016fm syst\u00e9m\u016f i instalat\u00e9r\u016fm. Vysok\u00e9 jmenovit\u00e9 nap\u011bt\u00ed sp\u00edna\u010de a\u017e 1200 V DC spolu s mechanickou odolnost\u00ed 18 000 operac\u00ed zaji\u0161\u0165uj\u00ed dlouhodobou ochranu cenn\u00fdch sol\u00e1rn\u00edch investic.<\/p>\n<p>Volba stejnosm\u011brn\u00e9ho izol\u00e1toru VOPV \u0159ady L1 znamen\u00e1 v\u00fdb\u011br v\u00fdrobku, kter\u00fd up\u0159ednost\u0148uje bezpe\u010dnost bez kompromis\u016f v kvalit\u011b nebo v\u00fdkonu. A\u0165 u\u017e se jedn\u00e1 o instalaci na st\u0159e\u0161e obytn\u00e9ho domu nebo o komer\u010dn\u00ed sol\u00e1rn\u00ed pole, tento odd\u011blovac\u00ed sp\u00edna\u010d poskytuje spolehlivou ochranu nezbytnou pro ka\u017ed\u00fd fotovoltaick\u00fd syst\u00e9m.<\/p>\n<p>Chcete-li z\u00edskat dal\u0161\u00ed informace o sp\u00edna\u010di VOPV DC Isolator Series L1 nebo si jej objednat, kontaktujte n\u00e1\u0161 prodejn\u00ed t\u00fdm je\u0161t\u011b dnes. Vyzkou\u0161ejte rozd\u00edl, kter\u00fd m\u016f\u017ee ve va\u0161\u00ed sol\u00e1rn\u00ed instalaci p\u0159in\u00e9st prvot\u0159\u00eddn\u00ed technologie izolace.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"markdown\">\n<p>Objevte \u0159adu stejnosm\u011brn\u00fdch izol\u00e1tor\u016f VIOX VOPV L1, kter\u00e9 jsou navr\u017eeny pro kritickou bezpe\u010dnost v oblasti <strong>1-20kW<\/strong> sol\u00e1rn\u00ed fotovoltaick\u00e9 instalace. Zaji\u0161\u0165uje spolehlivou izolaci stejnosm\u011brn\u00e9ho proudu a\u017e do <strong>1200V<\/strong> s rychlou (&lt;8 ms) kontrolou oblouku. Je vybaven uzamykatelnou rukojet\u00ed a snadnou mont\u00e1\u017e\u00ed na li\u0161tu DIN. Certifik\u00e1t IEC\/AS.<\/p>\n<\/div>\n<div class=\"MessageFooter-bVqShU NkvHX\">\n<div class=\"MessageMetadata-cfJJzU kPJntZ message-tokens has-metrics\"><\/div>\n<\/div>","protected":false},"featured_media":14973,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[134],"product_tag":[],"class_list":{"0":"post-14972","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-photovoltaic-dc-isolator-switch","7":"desktop-align-left","8":"tablet-align-left","9":"mobile-align-left","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product\/14972","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/comments?post=14972"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media\/14973"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media?parent=14972"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product_brand?post=14972"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product_cat?post=14972"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product_tag?post=14972"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}