{"id":14340,"date":"2025-03-20T11:52:30","date_gmt":"2025-03-20T03:52:30","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=14340"},"modified":"2025-03-20T11:52:30","modified_gmt":"2025-03-20T03:52:30","slug":"viox-fct18-adr-pulse-delayed-timer-relay-with-control-signal","status":"publish","type":"product","link":"https:\/\/test.viox.com\/cs\/produkt\/viox-fct18-adr-pulse-delayed-timer-relay-with-control-signal\/","title":{"rendered":"VIOX FCT18-AdR Impulsn\u00ed \u010dasov\u00e9 rel\u00e9 s \u0159\u00eddic\u00edm sign\u00e1lem"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>\u00davod<\/h2>\n<p>VIOX FCT18-AdR je profesion\u00e1ln\u00ed \u010dasov\u00e9 rel\u00e9 s pulzn\u00edm zpo\u017ed\u011bn\u00edm ur\u010den\u00e9 pro p\u0159esn\u00e9 \u0159\u00edzen\u00ed \u010dasov\u00e1n\u00ed v pr\u016fmyslov\u00e9 automatizaci, v\u00fdrobn\u00edch procesech a \u0159\u00eddic\u00edch syst\u00e9mech. Toto univerz\u00e1ln\u00ed \u010dasov\u00e9 rel\u00e9 nab\u00edz\u00ed v\u00fdjime\u010dnou flexibilitu d\u00edky funkci zpo\u017ed\u011bn\u00ed zapnut\u00ed (spou\u0161t\u011bn\u00ed n\u00e1b\u011b\u017en\u00e9 hrany), v\u00edce mo\u017enostem \u010dasov\u00e9ho rozsahu a spolehliv\u00e9mu v\u00fdkonu v r\u016fzn\u00fdch provozn\u00edch podm\u00ednk\u00e1ch.<\/p>\n<p>FCT18-AdR je navr\u017een pro pr\u016fmyslov\u00e9 prost\u0159ed\u00ed a kombinuje p\u0159esn\u00e9 \u010dasov\u00e1n\u00ed, snadnou konfiguraci a robustn\u00ed konstrukci, aby poskytoval konzistentn\u00ed a spolehliv\u00fd provoz pro va\u0161e kritick\u00e9 \u010dasovac\u00ed aplikace. A\u0165 u\u017e pot\u0159ebujete kr\u00e1tk\u00e9 impulsy m\u011b\u0159en\u00e9 v sekund\u00e1ch nebo rozs\u00e1hl\u00e9 \u010dasov\u00e9 sekvence trvaj\u00edc\u00ed n\u011bkolik dn\u00ed, toto \u010dasov\u00e9 rel\u00e9 poskytuje pot\u0159ebn\u00e9 \u0159\u00edzen\u00ed s minim\u00e1ln\u00ed chybovost\u00ed a maxim\u00e1ln\u00ed spolehlivost\u00ed.<\/p>\n<h2>Kl\u00ed\u010dov\u00e9 vlastnosti a v\u00fdhody<\/h2>\n<h3>P\u0159esn\u00e9 \u0159\u00edzen\u00ed \u010dasov\u00e1n\u00ed<\/h3>\n<ul>\n<li><strong>\u0160irok\u00fd v\u00fdb\u011br \u010dasov\u00e9ho rozsahu<\/strong>: Nastaviteln\u00fd od 0,1 sekundy do 100 dn\u016f<\/li>\n<li><strong>V\u00fdjime\u010dn\u00e1 p\u0159esnost<\/strong>: Chyba \u010dasu men\u0161\u00ed ne\u017e 0,5%, s \u010dasovou odchylkou pouh\u00fdch 0,1%.<\/li>\n<li><strong>Vysok\u00e1 p\u0159esnost opakov\u00e1n\u00ed<\/strong>: p\u0159esnost 0,5% pro konzistentn\u00ed v\u00fdkon<\/li>\n<\/ul>\n<h3>Flexibiln\u00ed mo\u017enosti pou\u017eit\u00ed<\/h3>\n<ul>\n<li><strong>Zpo\u017ed\u011bn\u00ed zapnut\u00ed (spou\u0161t\u011bn\u00ed vzestupnou hranou)<\/strong>: P\u0159esn\u00e9 \u010dasov\u00e9 sekvence iniciovan\u00e9 p\u0159echody sign\u00e1l\u016f<\/li>\n<li><strong>Nastaven\u00ed v\u00edce \u010das\u016f<\/strong>: 10 r\u016fzn\u00fdch mo\u017enost\u00ed rozsahu pro maxim\u00e1ln\u00ed v\u0161estrannost pou\u017eit\u00ed<\/li>\n<li><strong>Nastaven\u00ed pom\u011bru<\/strong>: Vyla\u010fte si \u010dasov\u00e1n\u00ed pomoc\u00ed 19 nastaven\u00ed p\u0159evodov\u00e9ho pom\u011bru od 10% do 100%.<\/li>\n<\/ul>\n<h3>V\u0161estrann\u00e9 mo\u017enosti nap\u00e1jen\u00ed a v\u00fdstupu<\/h3>\n<ul>\n<li><strong>\u0160irok\u00fd rozsah nap\u00e1jen\u00ed<\/strong>: Kompatibiln\u00ed s 12 a\u017e 240 VAC\/DC<\/li>\n<li><strong>Konfigurace se dv\u011bma v\u00fdstupy<\/strong>: K dispozici s 1 nebo 2 kontakty CO<\/li>\n<li><strong>Mo\u017enosti \u0159\u00eddic\u00edho sign\u00e1lu<\/strong>: Volba mezi konfigurac\u00ed \u0159\u00eddic\u00edho sign\u00e1lu NPN nebo PNP<\/li>\n<\/ul>\n<h3>Spolehlivost pr\u016fmyslov\u00e9 t\u0159\u00eddy<\/h3>\n<ul>\n<li><strong>Siln\u00e1 schopnost ochrany proti ru\u0161en\u00ed<\/strong>: Zachov\u00e1v\u00e1 p\u0159esnost i v hlu\u010dn\u00e9m elektrick\u00e9m prost\u0159ed\u00ed.<\/li>\n<li><strong>Prodlou\u017een\u00e1 provozn\u00ed \u017eivotnost<\/strong>: Mechanick\u00e1 \u017eivotnost 10^7 operac\u00ed, elektrick\u00e1 \u017eivotnost 10^5 operac\u00ed.<\/li>\n<li><strong>\u0160irok\u00fd teplotn\u00ed rozsah<\/strong>: Pracuje p\u0159i teplot\u00e1ch od -20 \u00b0C do +60 \u00b0C.<\/li>\n<\/ul>\n<h3>Snadn\u00e1 implementace<\/h3>\n<ul>\n<li><strong>Mont\u00e1\u017e na li\u0161tu DIN<\/strong>: Kompatibiln\u00ed s normou EN\/IEC 60715 pro rychlou instalaci<\/li>\n<li><strong>Jasn\u00e9 vizu\u00e1ln\u00ed indik\u00e1tory<\/strong>: Zelen\u00e1 LED dioda pro indikaci nap\u00e1jen\u00ed a \u010derven\u00e1 LED dioda pro indikaci stavu rel\u00e9.<\/li>\n<li><strong>Kompaktn\u00ed design<\/strong>: Prostorov\u011b \u00fasporn\u00e9 rozm\u011bry 90 mm \u00d7 18 mm \u00d7 64 mm<\/li>\n<\/ul>\n<h2>Pochopen\u00ed zpo\u017ed\u011bn\u00ed zapnut\u00ed (spou\u0161t\u011bn\u00ed vzestupnou hranou)<\/h2>\n<p>Funkce \u010dasov\u00e1n\u00ed FCT18-AdR vyu\u017e\u00edv\u00e1 zpo\u017ed\u011bn\u00ed zapnut\u00ed s n\u00e1b\u011b\u017enou hranou spou\u0161t\u011bn\u00ed, co\u017e umo\u017e\u0148uje p\u0159esnou kontrolu nad t\u00edm, kdy se p\u0159ipojen\u00e9 za\u0159\u00edzen\u00ed aktivuje. Sch\u00e9ma \u010dasov\u00e1n\u00ed zn\u00e1zor\u0148uje, jak to funguje:<\/p>\n<ol>\n<li>Po p\u0159iveden\u00ed vstupn\u00edho nap\u011bt\u00ed (Un) je jednotka nap\u00e1jena.<\/li>\n<li>Kdy\u017e \u0159\u00eddic\u00ed sign\u00e1l (S) stoupne z n\u00edzk\u00e9 na vysokou hodnotu, za\u010dne \u010dasov\u00e1 sekvence.<\/li>\n<li>Po uplynut\u00ed nastaven\u00e9 doby zpo\u017ed\u011bn\u00ed (T1) se aktivuje rel\u00e9 (R).<\/li>\n<li>Rel\u00e9 z\u016fst\u00e1v\u00e1 aktivn\u00ed, dokud neuplyne nastaven\u00e1 provozn\u00ed doba (T2).<\/li>\n<li>Tato sekvence se opakuje s ka\u017edou vzestupnou hranou \u0159\u00eddic\u00edho sign\u00e1lu.<\/li>\n<\/ol>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-14341\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-timing-function.webp\" alt=\"VIOX FCT18-AdR Pulse Delayed Timer Relay with Control Signal timing function\" width=\"880\" height=\"274\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-timing-function.webp 880w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-timing-function-300x93.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-timing-function-768x239.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-timing-function-18x6.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-timing-function-600x187.webp 600w\" sizes=\"(max-width: 880px) 100vw, 880px\" \/><\/p>\n<p>D\u00edky t\u00e9to funkci je FCT18-AdR ide\u00e1ln\u00ed pro aplikace vy\u017eaduj\u00edc\u00ed p\u0159esn\u00e9 \u010dasov\u00e1n\u00ed po spou\u0161t\u011bc\u00ed ud\u00e1losti, jako jsou sekven\u010dn\u00ed operace stroje, procesy s odlo\u017een\u00fdm startem nebo \u010dasov\u011b \u0159\u00edzen\u00e9 cykly.<\/p>\n<h2>Komplexn\u00ed mo\u017enosti \u010dasov\u00e9ho rozsahu<\/h2>\n<p>FCT18-AdR nab\u00edz\u00ed v\u00fdjime\u010dnou v\u0161estrannost d\u00edky \u0161irok\u00e9 \u0161k\u00e1le nastaven\u00ed \u010dasu:<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14342\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-time-setting.webp\" alt=\"VIOX FCT18-AdR Pulse Delayed Timer Relay with Control Signal time setting\" width=\"816\" height=\"308\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-time-setting.webp 816w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-time-setting-300x113.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-time-setting-768x290.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-time-setting-18x7.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-time-setting-600x226.webp 600w\" sizes=\"(max-width: 816px) 100vw, 816px\" \/><\/p>\n<table>\n<thead>\n<tr>\n<th>\u010casov\u00fd rozsah<\/th>\n<th>P\u0159\u00edklady aplikac\u00ed<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>0.1-1s<\/td>\n<td>Rychl\u00e9 \u0159\u00edzen\u00ed procesu, rychl\u00e9 cyklick\u00e9 operace<\/td>\n<\/tr>\n<tr>\n<td>1-10s<\/td>\n<td>Kr\u00e1tk\u00e9 sekvence zpo\u017ed\u011bn\u00ed, kr\u00e1tk\u00e9 pauzy za\u0159\u00edzen\u00ed<\/td>\n<\/tr>\n<tr>\n<td>0.1-1m<\/td>\n<td>\u010casov\u011b omezen\u00e9 f\u00e1ze procesu, kr\u00e1tk\u00e1 doba vychladnut\u00ed<\/td>\n<\/tr>\n<tr>\n<td>1-10m<\/td>\n<td>Roz\u0161\u00ed\u0159en\u00e9 operace zpracov\u00e1n\u00ed, vytvrzov\u00e1n\u00ed materi\u00e1lu<\/td>\n<\/tr>\n<tr>\n<td>0,1-1 hod.<\/td>\n<td>Na\u010dasov\u00e1n\u00ed v\u00fdrobn\u00edho cyklu, zah\u0159\u00edv\u00e1n\u00ed za\u0159\u00edzen\u00ed<\/td>\n<\/tr>\n<tr>\n<td>1-10 hodin<\/td>\n<td>Dlouh\u00e9 pr\u016fmyslov\u00e9 procesy, prodlou\u017een\u00e9 provozy<\/td>\n<\/tr>\n<tr>\n<td>0.1-1den<\/td>\n<td>Celodenn\u00ed \u010dasov\u00e9 sekvence, no\u010dn\u00ed provoz<\/td>\n<\/tr>\n<tr>\n<td>1-10dn\u00ed<\/td>\n<td>V\u00edcedenn\u00ed zpracov\u00e1n\u00ed, roz\u0161\u00ed\u0159en\u00e9 sledov\u00e1n\u00ed<\/td>\n<\/tr>\n<tr>\n<td>3-30denn\u00ed<\/td>\n<td>M\u011bs\u00ed\u010dn\u00ed na\u010dasov\u00e1n\u00ed \u00fadr\u017eby, dlouhodob\u00e9 procesy<\/td>\n<\/tr>\n<tr>\n<td>10-100dn\u00ed<\/td>\n<td>\u010ctvrtletn\u00ed operace, prodlou\u017een\u00e9 monitorovac\u00ed cykly<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Ka\u017ed\u00fd \u010dasov\u00fd rozsah lze snadno zvolit pomoc\u00ed intuitivn\u00edho oto\u010dn\u00e9ho ovlada\u010de a p\u0159esn\u00e9 \u010dasov\u00e1n\u00ed v r\u00e1mci ka\u017ed\u00e9ho rozsahu lze jemn\u011b doladit pomoc\u00ed ovlada\u010de nastaven\u00ed pom\u011bru, kter\u00fd poskytuje 19 bod\u016f nastaven\u00ed od 10% do 100% zvolen\u00e9ho rozsahu.<\/p>\n<h2>Nastaven\u00ed pom\u011bru<\/h2>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14343\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-ratio-setting.webp\" alt=\"VIOX FCT18-AdR Pulse Delayed Timer Relay with Control Signal ratio setting\" width=\"976\" height=\"260\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-ratio-setting.webp 976w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-ratio-setting-300x80.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-ratio-setting-768x205.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-ratio-setting-18x5.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-ratio-setting-600x160.webp 600w\" sizes=\"(max-width: 976px) 100vw, 976px\" \/><\/p>\n<h2>Technick\u00e9 specifikace<\/h2>\n<h3>Elektrick\u00e9 parametry<\/h3>\n<ul>\n<li><strong>Vstupn\u00ed svorka<\/strong>: A1-A2<\/li>\n<li><strong>Rozsah nap\u011bt\u00ed<\/strong>: AC 230V \/ DC24V \/ AC\/DC 12-240V<\/li>\n<li><strong>Spot\u0159eba energie<\/strong>: AC 3,5VA \/ DC 2,0W<\/li>\n<li><strong>Tolerance nap\u011bt\u00ed<\/strong>: -15% ~ +10%<\/li>\n<li><strong>Indikace dod\u00e1vky<\/strong>: Zelen\u00e1 LED dioda<\/li>\n<li><strong>Indikace rel\u00e9<\/strong>: \u010cerven\u00e1 LED dioda<\/li>\n<\/ul>\n<h3>\u010casov\u00e9 parametry<\/h3>\n<ul>\n<li><strong>\u010casov\u00e9 rozsahy<\/strong>: a.1s - 100dn\u00ed<\/li>\n<li><strong>Metoda nastaven\u00ed \u010dasu<\/strong>: Oto\u010dn\u00fd voli\u010d s volbou tla\u010d\u00edtek<\/li>\n<li><strong>\u010casov\u00e1 odchylka<\/strong>: 0.1%<\/li>\n<li><strong>P\u0159esnost opakov\u00e1n\u00ed<\/strong>: 0.5%<\/li>\n<li><strong>Teplotn\u00ed koeficient<\/strong>: 0,05%\/\u00b0C p\u0159i 20\u00b0C (0,05%\/\u00b0F p\u0159i 68\u00b0F)<\/li>\n<\/ul>\n<h3>V\u00fdstupn\u00ed specifikace<\/h3>\n<ul>\n<li><strong>Mo\u017enosti v\u00fdstupn\u00edch kontakt\u016f<\/strong>:\n<ul>\n<li>FCT18-AdR1: 1\u00d7SPDT kontakt<\/li>\n<li>FCT18-AdR2: 2\u00d7SPDT kontakty<\/li>\n<\/ul>\n<\/li>\n<li><strong>Jmenovit\u00fd proud<\/strong>: 16 A na kontakt<\/li>\n<li><strong>Mechanick\u00e1 \u017eivotnost<\/strong>: 10^7 operac\u00ed<\/li>\n<li><strong>Elektrick\u00e1 \u017eivotnost<\/strong>: 10^5 operac\u00ed<\/li>\n<\/ul>\n<h3>Hodnocen\u00ed \u017eivotn\u00edho prost\u0159ed\u00ed<\/h3>\n<ul>\n<li><strong>Rozsah okoln\u00ed teploty<\/strong>: -20\u00b0C a\u017e +60\u00b0C (-40\u00b0F a\u017e +85\u00b0F)<\/li>\n<li><strong>Zp\u016fsob mont\u00e1\u017ee<\/strong>: DIN li\u0161ta EN\/IEC 60715<\/li>\n<li><strong>Stupe\u0148 kryt\u00ed IP<\/strong>: IP20<\/li>\n<li><strong>\u00darove\u0148 zne\u010di\u0161t\u011bn\u00ed<\/strong>: 2<\/li>\n<li><strong>Instalovan\u00e1 nadmo\u0159sk\u00e1 v\u00fd\u0161ka<\/strong>: \u22642200m<\/li>\n<\/ul>\n<h3>Fyzick\u00e9 vlastnosti<\/h3>\n<ul>\n<li><strong>Rozm\u011bry<\/strong>: 90 mm \u00d7 18 mm \u00d7 64 mm<\/li>\n<li><strong>Hmotnost<\/strong>: P\u0159ibli\u017en\u011b 90 g<\/li>\n<li><strong>D\u00e9lka odizolov\u00e1n\u00ed<\/strong>: 7 mm (0,28 palce)<\/li>\n<li><strong>Maxim\u00e1ln\u00ed velikost kabelu<\/strong>: AWG13-20, 0,4 N-m<\/li>\n<\/ul>\n<h3>Normy pro dodr\u017eov\u00e1n\u00ed p\u0159edpis\u016f<\/h3>\n<ul>\n<li>GB\/T 14048.5<\/li>\n<li>IEC60947-5-1<\/li>\n<li>EN6812-1<\/li>\n<\/ul>\n<h2>Pr\u016fvodce v\u00fdb\u011brem modelu<\/h2>\n<p>FCT18-AdR se \u0159\u00edd\u00ed jednoduch\u00fdm k\u00f3dovac\u00edm syst\u00e9mem, kter\u00fd v\u00e1m pom\u016f\u017ee vybrat spr\u00e1vn\u00fd model pro va\u0161i aplikaci:<\/p>\n<p><strong>FCT18-AdR X Y Z<\/strong><\/p>\n<p>Kde:<\/p>\n<ol>\n<li><strong>Funkce (X)<\/strong>:\n<ul>\n<li>AdR: funkce \u010dasov\u00e1n\u00ed zapnut\u00ed a zpo\u017ed\u011bn\u00ed<\/li>\n<\/ul>\n<\/li>\n<li><strong>Typ v\u00fdstupu (Y)<\/strong>:\n<ul>\n<li>1: 1CO kontakt<\/li>\n<li>2: kontakty 2CO<\/li>\n<\/ul>\n<\/li>\n<li><strong>Nap\u00e1jec\u00ed nap\u011bt\u00ed (Z)<\/strong>:\n<ul>\n<li>A: AC230V<\/li>\n<li>D: DC24V<\/li>\n<li>W: AC\/DC12-240V<\/li>\n<\/ul>\n<\/li>\n<li><strong>Typ \u0159\u00eddic\u00edho sign\u00e1lu<\/strong>:\n<ul>\n<li>N: NPN<\/li>\n<li>P: PNP<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<p>Nap\u0159\u00edklad \"FCT18-AdR 1 W N\" ozna\u010duje \u010dasov\u00e9 rel\u00e9 s funkc\u00ed zpo\u017ed\u011bn\u00ed sepnut\u00ed, 1 kontaktem CO, nap\u00e1jec\u00edm nap\u011bt\u00edm AC\/DC 12-240 V a typem \u0159\u00eddic\u00edho sign\u00e1lu NPN.<\/p>\n<h2>Sch\u00e9mata zapojen\u00ed<\/h2>\n<p>FCT18-AdR nab\u00edz\u00ed jednoduch\u00e9 konfigurace zapojen\u00ed:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14344\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-wiring.webp\" alt=\"VIOX FCT18-AdR Pulse Delayed Timer Relay with Control Signal wiring\" width=\"386\" height=\"394\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-wiring.webp 386w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-wiring-294x300.webp 294w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-wiring-12x12.webp 12w\" sizes=\"(max-width: 386px) 100vw, 386px\" \/><\/p>\n<h3>Konfigurace NPN<\/h3>\n<ul>\n<li>P\u0159ipojen\u00ed nap\u00e1jen\u00ed ke svork\u00e1m Un<\/li>\n<li>P\u0159ipojte svorku S pro vstup \u0159\u00eddic\u00edho sign\u00e1lu<\/li>\n<li>V\u00fdstupn\u00ed svorky:\n<ul>\n<li>QA1 (DC+ \/ AC L)<\/li>\n<li>QA2 (DC- \/ AC N)<\/li>\n<\/ul>\n<\/li>\n<li>\u010c\u00edsla termin\u00e1l\u016f: 12, 14, 22, 24 pro v\u00fdstupy a 11, 21 pro spole\u010dn\u00e1 p\u0159ipojen\u00ed.<\/li>\n<\/ul>\n<h3>Konfigurace PNP<\/h3>\n<ul>\n<li>P\u0159ipojen\u00ed nap\u00e1jen\u00ed ke svork\u00e1m Un<\/li>\n<li>P\u0159ipojte svorku S pro vstup \u0159\u00eddic\u00edho sign\u00e1lu<\/li>\n<li>V\u00fdstupn\u00ed svorky z\u016fst\u00e1vaj\u00ed stejn\u00e9 jako v konfiguraci NPN<\/li>\n<\/ul>\n<p>D\u00edky p\u0159ehledn\u011b ozna\u010den\u00fdm svork\u00e1m a p\u0159ilo\u017een\u00fdm sch\u00e9mat\u016fm zapojen\u00ed je instalace rychl\u00e1 a jednoduch\u00e1, a to i v p\u0159\u00edpad\u011b slo\u017eit\u00fdch \u0159\u00eddic\u00edch syst\u00e9m\u016f.<\/p>\n<h2>Rozm\u011br<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14345\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-dimension.webp\" alt=\"VIOX FCT18-AdR Pulse Delayed Timer Relay with Control Signal dimension\" width=\"386\" height=\"370\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-dimension.webp 386w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-dimension-300x288.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AdR-Pulse-Delayed-Timer-Relay-with-Control-Signal-dimension-13x12.webp 13w\" sizes=\"(max-width: 386px) 100vw, 386px\" \/><\/p>\n<h2>Aplikace<\/h2>\n<p>Impulzn\u00ed \u010dasov\u00e9 rel\u00e9 FCT18-AdR vynik\u00e1 v mnoha pr\u016fmyslov\u00fdch a komer\u010dn\u00edch aplikac\u00edch:<\/p>\n<h3>Pr\u016fmyslov\u00e1 automatizace<\/h3>\n<ul>\n<li><strong>Sekven\u010dn\u00ed \u0159\u00edzen\u00ed stroje<\/strong>: Vytv\u00e1\u0159en\u00ed p\u0159esn\u00fdch \u010dasov\u00fdch sekvenc\u00ed pro v\u00edcestup\u0148ov\u00e9 operace<\/li>\n<li><strong>Dopravn\u00edkov\u00e9 p\u00e1sov\u00e9 syst\u00e9my<\/strong>: \u0158\u00edzen\u00ed rozestup\u016f a na\u010dasov\u00e1n\u00ed mezi pohyby v\u00fdrobk\u016f<\/li>\n<li><strong>Balic\u00ed za\u0159\u00edzen\u00ed<\/strong>: Koordinace na\u010dasov\u00e1n\u00ed pln\u011bn\u00ed, uzav\u00edr\u00e1n\u00ed a ozna\u010dov\u00e1n\u00ed etiketami<\/li>\n<\/ul>\n<h3>V\u00fdrobn\u00ed procesy<\/h3>\n<ul>\n<li><strong>\u0158\u00edzen\u00ed \u010dasov\u00e1n\u00ed procesu<\/strong>: Zaji\u0161t\u011bn\u00ed konzistentn\u00edho na\u010dasov\u00e1n\u00ed kritick\u00fdch v\u00fdrobn\u00edch krok\u016f<\/li>\n<li><strong>D\u00e1vkov\u00e9 zpracov\u00e1n\u00ed<\/strong>: Udr\u017eujte p\u0159esn\u00e9 doby trv\u00e1n\u00ed cykl\u016f m\u00edch\u00e1n\u00ed, oh\u0159evu nebo chlazen\u00ed.<\/li>\n<li><strong>Syst\u00e9my kontroly kvality<\/strong>: \u010casov\u00e9 testovac\u00ed sekvence pro konzistentn\u00ed hodnocen\u00ed v\u00fdrobk\u016f<\/li>\n<\/ul>\n<h3>Stavebn\u00ed syst\u00e9my<\/h3>\n<ul>\n<li><strong>\u0158\u00edzen\u00ed HVAC<\/strong>: \u0158\u00edzen\u00ed \u010dasov\u00e1n\u00ed syst\u00e9m\u016f v\u011btr\u00e1n\u00ed a klimatizace<\/li>\n<li><strong>Sekvence osv\u011btlen\u00ed<\/strong>: Vytv\u00e1\u0159en\u00ed \u010dasovan\u00fdch vzor\u016f osv\u011btlen\u00ed pro \u00fa\u010dely zabezpe\u010den\u00ed nebo zobrazen\u00ed<\/li>\n<li><strong>Ovl\u00e1d\u00e1n\u00ed \u010derpadla<\/strong>: Zabra\u0148te vodn\u00edmu r\u00e1zu pomoc\u00ed \u010dasov\u00e9ho ovl\u00e1d\u00e1n\u00ed ventil\u016f a \u010derpadel.<\/li>\n<\/ul>\n<h3>Bezpe\u010dnostn\u00ed syst\u00e9my<\/h3>\n<ul>\n<li><strong>\u0158\u00edzen\u00ed nouzov\u00e9 sekvence<\/strong>: Vytv\u00e1\u0159en\u00ed \u010dasov\u00fdch sekvenc\u00ed pro reakce na mimo\u0159\u00e1dn\u00e9 ud\u00e1losti<\/li>\n<li><strong>Varovn\u00e9 syst\u00e9my<\/strong>: \u010casov\u00e1 aktivace alarm\u016f, sv\u011btel a dal\u0161\u00edch v\u00fdstra\u017en\u00fdch indik\u00e1tor\u016f<\/li>\n<li><strong>Z\u00e1mkov\u00e9 syst\u00e9my<\/strong>: Spr\u00e1va \u010dasov\u00e9ho \u0159\u00edzen\u00ed p\u0159\u00edstupu do zabezpe\u010den\u00fdch oblast\u00ed<\/li>\n<\/ul>\n<h2>Instalace a nastaven\u00ed<\/h2>\n<p>Instalace FCT18-AdR je jednoduch\u00e1 d\u00edky konstrukci pro mont\u00e1\u017e na li\u0161tu DIN a p\u0159ehledn\u00e9mu ozna\u010den\u00ed svorek:<\/p>\n<ol>\n<li><strong>Mont\u00e1\u017e rel\u00e9<\/strong>: P\u0159ipevn\u011bte na jakoukoli standardn\u00ed li\u0161tu DIN podle specifikace EN\/IEC 60715.<\/li>\n<li><strong>P\u0159ipojen\u00ed nap\u00e1jen\u00ed<\/strong>: P\u0159ipojte p\u0159\u00edslu\u0161n\u00e9 nap\u011bt\u00ed ke svork\u00e1m Un<\/li>\n<li><strong>P\u0159ipojen\u00ed \u0159\u00eddic\u00edho sign\u00e1lu<\/strong>: P\u0159ipojte \u0159\u00eddic\u00ed sign\u00e1l ke svorce S<\/li>\n<li><strong>P\u0159ipojen\u00ed v\u00fdstup\u016f<\/strong>: P\u0159ipojte ovl\u00e1dan\u00e1 za\u0159\u00edzen\u00ed k p\u0159\u00edslu\u0161n\u00fdm v\u00fdstupn\u00edm svork\u00e1m.<\/li>\n<li><strong>Nastaven\u00ed \u010dasov\u00e9ho rozsahu<\/strong>: Oto\u010dn\u00fdm voli\u010dem zvolte po\u017eadovan\u00fd \u010dasov\u00fd rozsah.<\/li>\n<li><strong>Nastaven\u00ed pom\u011bru<\/strong>: P\u0159esn\u00e9 nastaven\u00ed \u010dasov\u00e1n\u00ed zvolen\u00edm p\u0159\u00edslu\u0161n\u00e9ho procenta na voli\u010di p\u0159evodov\u00e9ho pom\u011bru.<\/li>\n<li><strong>Testovac\u00ed provoz<\/strong>: P\u0159ed dokon\u010den\u00edm instalace ov\u011b\u0159te spr\u00e1vn\u00e9 na\u010dasov\u00e1n\u00ed a fungov\u00e1n\u00ed.<\/li>\n<\/ol>\n<p>Kompaktn\u00ed konstrukce jednotky umo\u017e\u0148uje instalaci ve st\u00edsn\u011bn\u00fdch prostor\u00e1ch a p\u0159ehledn\u00e9 vizu\u00e1ln\u00ed indik\u00e1tory usnad\u0148uj\u00ed sledov\u00e1n\u00ed provozn\u00edho stavu na prvn\u00ed pohled.<\/p>\n<h2>\u00dadr\u017eba a \u0159e\u0161en\u00ed probl\u00e9m\u016f<\/h2>\n<p>Za\u0159\u00edzen\u00ed FCT18-AdR je navr\u017eeno pro minim\u00e1ln\u00ed \u00fadr\u017ebu, ale dodr\u017eov\u00e1n\u00ed t\u011bchto tip\u016f zajist\u00ed optim\u00e1ln\u00ed v\u00fdkon:<\/p>\n<h3>B\u011b\u017en\u00e1 \u00fadr\u017eba<\/h3>\n<ul>\n<li>Pravideln\u011b kontrolujte t\u011bsnost svorek<\/li>\n<li>Zkontrolujte, zda se v nich nehromad\u00ed prach nebo ne\u010distoty, a podle pot\u0159eby je vy\u010dist\u011bte.<\/li>\n<li>Ov\u011b\u0159te, zda kontrolky LED funguj\u00ed spr\u00e1vn\u011b<\/li>\n<\/ul>\n<h3>B\u011b\u017en\u00e9 \u0159e\u0161en\u00ed pot\u00ed\u017e\u00ed<\/h3>\n<ul>\n<li><strong>\u017d\u00e1dn\u00e1 indikace nap\u00e1jen\u00ed<\/strong>: Zkontrolujte nap\u00e1jen\u00ed a p\u0159ipojen\u00ed ke svork\u00e1m Un<\/li>\n<li><strong>Rel\u00e9 se neaktivuje<\/strong>: Ov\u011b\u0159te, zda je \u0159\u00eddic\u00ed sign\u00e1l spr\u00e1vn\u011b p\u0159ipojen a spou\u0161t\u00ed se.<\/li>\n<li><strong>Nespr\u00e1vn\u00e9 na\u010dasov\u00e1n\u00ed<\/strong>: Zkontrolujte, zda jsou ovlada\u010de nastaven\u00ed \u010dasu a pom\u011bru spr\u00e1vn\u011b um\u00edst\u011bny.<\/li>\n<li><strong>P\u0159eru\u0161ovan\u00fd provoz<\/strong>: Zkontrolujte, zda elektrick\u00fd \u0161um nebo ru\u0161en\u00ed neovliv\u0148uje \u0159\u00eddic\u00ed sign\u00e1l.<\/li>\n<\/ul>\n<h2>Pro\u010d si vybrat VIOX FCT18-AdR?<\/h2>\n<p>FCT18-AdR se odli\u0161uje od ostatn\u00edch \u010dasov\u00fdch rel\u00e9 na trhu z n\u011bkolika kl\u00ed\u010dov\u00fdch d\u016fvod\u016f:<\/p>\n<ul>\n<li><strong>V\u00fdjime\u010dn\u00e1 v\u0161estrannost<\/strong>: \u0160irok\u00fd \u010dasov\u00fd rozsah od 0,1 s do 100 dn\u016f pokr\u00fdv\u00e1 prakticky v\u0161echny \u010dasov\u00e9 aplikace.<\/li>\n<li><strong>Vynikaj\u00edc\u00ed p\u0159esnost<\/strong>: S \u010dasovou chybou men\u0161\u00ed ne\u017e 0,5% z\u016fstanou va\u0161e procesy p\u0159esn\u011b \u0159\u00edzeny.<\/li>\n<li><strong>Pr\u016fmyslov\u00e1 odolnost<\/strong>: Navr\u017eeno pro drsn\u00e9 prost\u0159ed\u00ed se silnou schopnost\u00ed ochrany proti ru\u0161en\u00ed.<\/li>\n<li><strong>Snadn\u00e1 konfigurace<\/strong>: Intuitivn\u00ed ovl\u00e1d\u00e1n\u00ed umo\u017e\u0148uje snadn\u00e9 nastaven\u00ed a se\u0159\u00edzen\u00ed<\/li>\n<li><strong>Spolehliv\u00fd v\u00fdkon<\/strong>: Konzistentn\u00ed provoz s p\u0159esnost\u00ed opakov\u00e1n\u00ed 0,5% zaji\u0161\u0165uje spolehliv\u00e9 \u010dasov\u00e1n\u00ed.<\/li>\n<li><strong>Komplexn\u00ed mo\u017enosti<\/strong>: K dispozici je n\u011bkolik konfigurac\u00ed, kter\u00e9 odpov\u00eddaj\u00ed va\u0161im specifick\u00fdm po\u017eadavk\u016fm.<\/li>\n<\/ul>\n<h2>Z\u00e1v\u011br<\/h2>\n<p>Impulsn\u00ed \u010dasov\u00e9 rel\u00e9 VIOX FCT18-AdR kombinuje p\u0159esn\u00e9 \u010dasov\u00e1n\u00ed, univerz\u00e1ln\u00ed mo\u017enosti konfigurace a spolehlivost pr\u016fmyslov\u00e9 t\u0159\u00eddy v kompaktn\u00edm, snadno instalovateln\u00e9m balen\u00ed. Od jednoduch\u00fdch \u010dasov\u00fdch sekvenc\u00ed m\u011b\u0159en\u00fdch v sekund\u00e1ch a\u017e po slo\u017eit\u00e9 operace trvaj\u00edc\u00ed dny nebo t\u00fddny, toto rel\u00e9 poskytuje \u0159\u00edzen\u00ed a spolehlivost, kter\u00e9 va\u0161e aplikace vy\u017eaduj\u00ed.<\/p>\n<p>D\u00edky funkci zpo\u017ed\u011bn\u00ed zapnut\u00ed, \u0161irok\u00e9mu rozsahu nap\u00e1jen\u00ed a mnoha mo\u017enostem v\u00fdstupu p\u0159edstavuje FCT18-AdR ide\u00e1ln\u00ed \u0159e\u0161en\u00ed \u010dasov\u00e1n\u00ed pro automatiza\u010dn\u00ed syst\u00e9my, v\u00fdrobn\u00ed procesy a \u0159\u00eddic\u00ed aplikace prakticky v ka\u017ed\u00e9m odv\u011btv\u00ed.<\/p>\n<p>Zvolte si pro sv\u00e9 pot\u0159eby \u010dasov\u00e9 rel\u00e9 VIOX FCT18-AdR a z\u00edskejte dokonalou rovnov\u00e1hu mezi p\u0159esnost\u00ed, spolehlivost\u00ed a snadn\u00fdm pou\u017eit\u00edm, kter\u00e9 dne\u0161n\u00ed pr\u016fmyslov\u00e9 aplikace vy\u017eaduj\u00ed.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"markdown\">\n<p>\u010casov\u00e9 rel\u00e9 VIOX FCT18-AdR s pulzn\u00edm zpo\u017ed\u011bn\u00edm nab\u00edz\u00ed p\u0159esn\u00e9 \u010dasov\u00e1n\u00ed zapnut\u00ed (n\u00e1b\u011b\u017en\u00e1 hrana) pro pr\u016fmyslovou automatizaci. Nab\u00edz\u00ed \u0161irok\u00fd rozsah 0,1 s-100 dn\u00ed, chybu &lt;0,5%, \u0159\u00edzen\u00ed NPN\/PNP, 1 nebo 2 kontakty SPDT, mont\u00e1\u017e na li\u0161tu DIN a nap\u00e1jen\u00ed AC\/DC 12-240 V. Ide\u00e1ln\u00ed pro sekven\u010dn\u00ed \u0159\u00edzen\u00ed a \u010dasov\u00e1n\u00ed proces\u016f.<\/p>\n<\/div>\n<div class=\"MessageFooter-cvwndn leDsBF\">\n<div class=\"MessageMetadata-claACb fcypgW message-tokens has-metrics\"><\/div>\n<\/div>","protected":false},"featured_media":14346,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[123,196],"product_tag":[],"class_list":{"0":"post-14340","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-relay","7":"product_cat-time-relay","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product\/14340","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/comments?post=14340"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media\/14346"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media?parent=14340"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product_brand?post=14340"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product_cat?post=14340"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product_tag?post=14340"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}