{"id":13916,"date":"2025-03-05T21:01:25","date_gmt":"2025-03-05T13:01:25","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=13916"},"modified":"2025-03-05T21:01:25","modified_gmt":"2025-03-05T13:01:25","slug":"vml01-2p-residual-current-operated-circuit-breaker-rccb","status":"publish","type":"product","link":"https:\/\/test.viox.com\/cs\/produkt\/vml01-2p-residual-current-operated-circuit-breaker-rccb\/","title":{"rendered":"VML01 2P Proudov\u00fd chr\u00e1ni\u010d (RCCB)"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>1. \u00davod do VML01 RCCB<\/h2>\n<p>Proudov\u00fd chr\u00e1ni\u010d VML01 (RCCB) p\u0159edstavuje vrchol technologie elektrick\u00e9 bezpe\u010dnosti a je navr\u017een tak, aby poskytoval komplexn\u00ed ochranu p\u0159ed elektrick\u00fdm nebezpe\u010d\u00edm v obytn\u00fdch, komer\u010dn\u00edch a pr\u016fmyslov\u00fdch aplikac\u00edch. Toto za\u0159\u00edzen\u00ed vyhovuj\u00edc\u00ed norm\u011b IEC\/EN 61008-1 nab\u00edz\u00ed vynikaj\u00edc\u00ed ochranu p\u0159ed \u00farazem elektrick\u00fdm proudem p\u0159i nep\u0159\u00edm\u00e9m dotyku, p\u0159\u00edm\u00e9m dotyku a poruch\u00e1ch izolace, kter\u00e9 by mohly v\u00e9st k nebezpe\u010d\u00ed po\u017e\u00e1ru.<\/p>\n<p>Jisti\u010d VML01 RCCB jako magnetick\u00fd proudov\u00fd chr\u00e1ni\u010d nep\u0159etr\u017eit\u011b sleduje rovnov\u00e1hu proudu prot\u00e9kaj\u00edc\u00edho \u017eiv\u00fdmi a nulov\u00fdmi vodi\u010di v elektrick\u00e9m obvodu. Kdy\u017e zjist\u00ed \u00fanik proudu do zem\u011b p\u0159esahuj\u00edc\u00ed pr\u00e1h citlivosti, rychle obvod odpoj\u00ed a zabr\u00e1n\u00ed tak potenci\u00e1ln\u011b \u017eivotu nebezpe\u010dn\u00fdm situac\u00edm.<\/p>\n<h2>2. Z\u00e1kladn\u00ed funkce a aplikace VML01 RCCB<\/h2>\n<h3>2.1 Z\u00e1kladn\u00ed funkce<\/h3>\n<ul>\n<li><strong>\u0158\u00edzen\u00ed elektrick\u00fdch obvod\u016f:<\/strong> Zaji\u0161\u0165uje spolehlivou spr\u00e1vu elektrick\u00fdch obvod\u016f<\/li>\n<li><strong>Osobn\u00ed ochrana:<\/strong> Chr\u00e1n\u00ed p\u0159ed nep\u0159\u00edm\u00fdm kontaktem a nab\u00edz\u00ed dodate\u010dnou ochranu p\u0159ed p\u0159\u00edm\u00fdm kontaktem.<\/li>\n<li><strong>Prevence po\u017e\u00e1rn\u00edho nebezpe\u010d\u00ed:<\/strong> Chr\u00e1n\u00ed instalace p\u0159ed nebezpe\u010d\u00edm po\u017e\u00e1ru v d\u016fsledku poruch izolace.<\/li>\n<\/ul>\n<h3>2.2 Odv\u011btv\u00ed aplikac\u00ed<\/h3>\n<p>VML01 RCCB poskytuje z\u00e1kladn\u00ed bezpe\u010dnost v r\u016fzn\u00fdch prost\u0159ed\u00edch:<\/p>\n<ul>\n<li><strong>Reziden\u010dn\u00ed prost\u0159ed\u00ed:<\/strong> Ochrana dom\u016f a obytn\u00fdch prostor<\/li>\n<li><strong>Terci\u00e1rn\u00ed sektor:<\/strong> Zaji\u0161t\u011bn\u00ed bezpe\u010dnosti v komer\u010dn\u00edch budov\u00e1ch, kancel\u00e1\u0159\u00edch a ve\u0159ejn\u00fdch za\u0159\u00edzen\u00edch<\/li>\n<li><strong>Pr\u016fmyslov\u00e9 prost\u0159ed\u00ed:<\/strong> Zabezpe\u010den\u00ed v\u00fdrobn\u00edch z\u00e1vod\u016f a v\u00fdrobn\u00edch za\u0159\u00edzen\u00ed<\/li>\n<\/ul>\n<h3>2.3 Specializovan\u00e9 aplikace<\/h3>\n<p>D\u00edky r\u016fzn\u00fdm mo\u017enostem citlivosti se VML01 RCCB dokonale hod\u00ed pro:<\/p>\n<ul>\n<li><strong>P\u0159esn\u00e1 ochrana p\u0159\u00edstroj\u016f:<\/strong> Citlivost 10 mA ide\u00e1ln\u00ed pro laboratorn\u00ed za\u0159\u00edzen\u00ed a koupelny<\/li>\n<li><strong>Zv\u00fd\u0161en\u00e1 osobn\u00ed bezpe\u010dnost:<\/strong> citlivost 30 mA zaji\u0161\u0165uj\u00edc\u00ed dodate\u010dnou ochranu proti p\u0159\u00edm\u00e9mu kontaktu<\/li>\n<li><strong>Koordinace syst\u00e9mu Zem\u011b:<\/strong> Citlivost 100 mA p\u0159i pr\u00e1ci s uzem\u0148ovac\u00edmi syst\u00e9my podle vzorce I\u00b2n &lt; 50\/R<\/li>\n<li><strong>Prevence po\u017e\u00e1rn\u00edho nebezpe\u010d\u00ed:<\/strong> Citlivost 300mA\/500mA chr\u00e1n\u00edc\u00ed p\u0159ed nep\u0159\u00edm\u00fdmi kontakty i rizikem po\u017e\u00e1ru<\/li>\n<\/ul>\n<h2>3. Technick\u00e9 specifikace VML01 RCCB<\/h2>\n<h3>3.1 Elektrick\u00e9 funkce<\/h3>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th>Parametr<\/th>\n<th>Specifikace<\/th>\n<\/tr>\n<tr>\n<td>Model \u010d.<\/td>\n<td>VML01<\/td>\n<\/tr>\n<tr>\n<td>Pol\u00e1ci<\/td>\n<td>2P, 4P<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00fd proud In<\/td>\n<td>16A, 25A, 32A, 40A, 63A, 80A, 100A<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00e1 citlivost I\u25b3n<\/td>\n<td>10mA (2P\/4P 16A-40A), 30mA, 100mA, 300mA<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00e9 nap\u011bt\u00ed Ue<\/td>\n<td>2P: 240V 4P: 415V<\/td>\n<\/tr>\n<tr>\n<td>Izola\u010dn\u00ed nap\u011bt\u00ed Ui<\/td>\n<td>500V<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00e1 frekvence<\/td>\n<td>50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00e1 zbytkov\u00e1 v\u00fdrobn\u00ed a p\u0159etv\u00e1rn\u00e1 kapacita I\u25b3m<\/td>\n<td>1500A<\/td>\n<\/tr>\n<tr>\n<td>Zkratov\u00fd proud Inc=I\u25b3c<\/td>\n<td>6000A, 10000A<\/td>\n<\/tr>\n<tr>\n<td>Typ (tvar vlny sn\u00edman\u00e9ho zemn\u00edho svodu)<\/td>\n<td>AC, A<\/td>\n<\/tr>\n<tr>\n<td>Doba j\u00edzdy<\/td>\n<td>Okam\u017eit\u00fd, Kr\u00e1tk\u00e9 \u010dasov\u00e9 zpo\u017ed\u011bn\u00ed, Selektivn\u00ed<\/td>\n<\/tr>\n<tr>\n<td>Doba p\u0159est\u00e1vky pod I\u25b3n<\/td>\n<td>&lt;0,1 s (norm\u00e1ln\u00ed typ), 10 ms-300 ms (typ ASi, G, KV), 150 ms-500 ms (typ S)<\/td>\n<\/tr>\n<tr>\n<td>Jmenovit\u00e9 impulzn\u00ed v\u00fddr\u017en\u00e9 nap\u011bt\u00ed(1,2\/50) Uimp<\/td>\n<td>6kV<\/td>\n<\/tr>\n<tr>\n<td>Dielektrick\u00e9 zku\u0161ebn\u00ed nap\u011bt\u00ed p\u0159i ind. Frekvence po dobu 1 min<\/td>\n<td>2.5<\/td>\n<\/tr>\n<tr>\n<td>Stupe\u0148 zne\u010di\u0161t\u011bn\u00ed<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Elektrick\u00e1 \u017eivotnost<\/td>\n<td>\u22652000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>3.2 Mechanick\u00e9 vlastnosti<\/h3>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th>Parametr<\/th>\n<th>Specifikace<\/th>\n<\/tr>\n<tr>\n<td>Mechanick\u00e1 \u017eivotnost<\/td>\n<td>\u22652000<\/td>\n<\/tr>\n<tr>\n<td>Indik\u00e1tor poruchov\u00e9ho proudu<\/td>\n<td>Ano<\/td>\n<\/tr>\n<tr>\n<td>Stupe\u0148 ochrany svorek<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Okoln\u00ed teplota (s denn\u00edm pr\u016fm\u011brem \u226435 \u00b0C)<\/td>\n<td>-25 \u00b0C a\u017e 55 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Skladovac\u00ed teplota<\/td>\n<td>-40 \u00b0C a\u017e 70 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>3.3 Parametry instalace<\/h3>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th>Parametr<\/th>\n<th>Specifikace<\/th>\n<\/tr>\n<tr>\n<td>Typ p\u0159ipojen\u00ed svorek<\/td>\n<td>P\u0159\u00edpojnice typu kabel\/kol\u00edk<\/td>\n<\/tr>\n<tr>\n<td>Velikost svorek naho\u0159e\/dole pro kabel<\/td>\n<td>25-35 mm\u00b2 \/ 18-3\/18-2 AWG<\/td>\n<\/tr>\n<tr>\n<td>Velikost svorek naho\u0159e\/dole pro p\u0159\u00edpojnici<\/td>\n<td>10\/16 mm\u00b2 \/ 18-8\/18-5 AWG<\/td>\n<\/tr>\n<tr>\n<td>Utahovac\u00ed moment<\/td>\n<td>2,5 N-m \/ 22 in-lbs.<\/td>\n<\/tr>\n<tr>\n<td>Mont\u00e1\u017e<\/td>\n<td>Na li\u0161tu DIN EN 60715 (35 mm) pomoc\u00ed rychloup\u00ednac\u00edho za\u0159\u00edzen\u00ed<\/td>\n<\/tr>\n<tr>\n<td>P\u0159ipojen\u00ed<\/td>\n<td>Shora a zdola<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>4. Pokro\u010dil\u00e9 ochrann\u00e9 funkce VML01 RCCB<\/h2>\n<h3>4.1 Mo\u017enosti citlivosti vypnut\u00ed<\/h3>\n<p>VML01 RCCB nab\u00edz\u00ed n\u011bkolik prahov\u00fdch hodnot citlivosti pro spln\u011bn\u00ed r\u016fzn\u00fdch po\u017eadavk\u016f na ochranu:<\/p>\n<ul>\n<li><strong>10 mA:<\/strong> Poskytuje p\u0159esnou ochranu proti \u00faniku p\u0159\u00edstroj\u016f a zv\u00fd\u0161enou bezpe\u010dnost p\u0159i instalaci v koupeln\u011b.<\/li>\n<li><strong>30 mA:<\/strong> Poskytuje dodate\u010dnou ochranu proti p\u0159\u00edm\u00e9mu dotyku, ide\u00e1ln\u00ed pro b\u011b\u017en\u00e9 bytov\u00e9 obvody.<\/li>\n<li><strong>100 mA:<\/strong> Koordinuje se se zemnic\u00ed soustavou podle vzorce I\u00b2n &lt; 50\/R, \u010d\u00edm\u017e zaji\u0161\u0165uje ochranu p\u0159ed nep\u0159\u00edm\u00fdm dotykem.<\/li>\n<li><strong>300mA\/500mA:<\/strong> Nab\u00edz\u00ed ochranu proti nep\u0159\u00edm\u00e9mu dotyku a nebezpe\u010d\u00ed po\u017e\u00e1ru, tak\u017ee je vhodn\u00fd pro pr\u016fmyslov\u00e9 aplikace.<\/li>\n<\/ul>\n<h3>4.2 Klasifikace doby vypnut\u00ed<\/h3>\n<p>VML01 RCCB m\u00e1 t\u0159i r\u016fzn\u00e9 mo\u017enosti doby vypnut\u00ed, kter\u00e9 vyhovuj\u00ed r\u016fzn\u00fdm ochrann\u00fdm strategi\u00edm:<\/p>\n<ul>\n<li><strong>Okam\u017eit\u00e9:<\/strong> Zaji\u0161\u0165uje okam\u017eit\u00e9 vypnut\u00ed bez \u010dasov\u00e9 prodlevy, \u010d\u00edm\u017e maximalizuje rychlost ochrany.<\/li>\n<li><strong>Kr\u00e1tk\u00e9 \u010dasov\u00e9 zpo\u017ed\u011bn\u00ed (ASi, G, KV):<\/strong> Zaru\u010duje vypnut\u00ed b\u011bhem minim\u00e1ln\u011b 10 ms a vyva\u017euje ochranu s provozn\u00ed stabilitou.<\/li>\n<li><strong>Selektivn\u00ed (S):<\/strong> Poskytuje \u00faplnou diskriminaci s neselektivn\u00edmi proudov\u00fdmi chr\u00e1ni\u010di um\u00edst\u011bn\u00fdmi za nimi, co\u017e umo\u017e\u0148uje koordinovanou ochranu ve v\u00edce\u00farov\u0148ov\u00fdch instalac\u00edch.<\/li>\n<\/ul>\n<h3>4.3 Klasifikace detekovateln\u00fdch forem vln<\/h3>\n<p>VML01 RCCB je k dispozici v r\u016fzn\u00fdch typech pro r\u016fzn\u00e9 profily unikaj\u00edc\u00edho proudu:<\/p>\n<ul>\n<li><strong>T\u0159\u00edda AC:<\/strong> Zaji\u0161\u0165uje vyp\u00edn\u00e1n\u00ed pomalu rostouc\u00edch sinusov\u00fdch st\u0159\u00eddav\u00fdch rezidu\u00e1ln\u00edch proud\u016f, vhodn\u00e9 pro z\u00e1kladn\u00ed instalace.<\/li>\n<li><strong>T\u0159\u00edda:<\/strong> Zaji\u0161\u0165uje vyp\u00edn\u00e1n\u00ed sinusov\u00fdch st\u0159\u00eddav\u00fdch rezidu\u00e1ln\u00edch proud\u016f a pulzn\u00edch stejnosm\u011brn\u00fdch rezidu\u00e1ln\u00edch proud\u016f, a\u0165 u\u017e jsou aplikov\u00e1ny n\u00e1hle nebo se zvy\u0161uj\u00ed pomalu.<\/li>\n<li><strong>Typ ASi:<\/strong> Kombinuje vlastnosti typu A s technologi\u00ed Super-immuned (Si) pro vysokou odolnost proti ne\u017e\u00e1douc\u00edmu vypnut\u00ed.<\/li>\n<li><strong>Typ F:<\/strong> Zahrnuje v\u0161echny funkce ASi a detekci vysokofrekven\u010dn\u00edch proud\u016f a\u017e do 1 kHz.<\/li>\n<li><strong>Typ B:<\/strong> Zahrnuje v\u0161echny funkce typu F a detekci hladk\u00fdch stejnosm\u011brn\u00fdch proud\u016f.<\/li>\n<li><strong>Typ B+:<\/strong> Nab\u00edz\u00ed v\u0161echny funkce typu B a detekci vysokofrekven\u010dn\u00edch proud\u016f a\u017e do 20 kHz.<\/li>\n<\/ul>\n<p>Pozn\u00e1mka: Typ ASi zahrnuje jak funkci G\/KV, tak funkci Si, \u010d\u00edm\u017e poskytuje komplexn\u00ed ochranu se zv\u00fd\u0161enou odolnost\u00ed.<\/p>\n<h2>5. Pokyny pro instalaci a integraci VML01 RCCB<\/h2>\n<h3>5.1 Rozm\u011bry a mont\u00e1\u017e<\/h3>\n<p>Na VML01 RCCB je ur\u010den pro snadnou instalaci na standardn\u00ed 35mm DIN li\u0161tu (EN 60715) pomoc\u00ed rychl\u00e9ho klip za\u0159\u00edzen\u00ed. Za\u0159\u00edzen\u00ed nab\u00edz\u00ed kompaktn\u00ed rozm\u011bry, \u017ee optimalizovat prostor v distribuci desek p\u0159i zachov\u00e1n\u00ed p\u0159\u00edstupnosti pro veden\u00ed a \u00fadr\u017ebu.<\/p>\n<h3>5.2 Selektivn\u00ed koordinace v distribu\u010dn\u00edch syst\u00e9mech<\/h3>\n<p>VML01 RCCB podporuje sofistikovan\u00e1 ochrann\u00e1 sch\u00e9mata prost\u0159ednictv\u00edm selektivn\u00ed koordinace. Ve v\u00edce\u00farov\u0148ov\u00fdch distribu\u010dn\u00edch syst\u00e9mech mohou b\u00fdt RCCB typu Selective (S) instalov\u00e1ny na m\u00edstech p\u0159ed proudem, zat\u00edmco typy Instantaneous nebo Short time delay jsou um\u00edst\u011bny za proudem. Toto uspo\u0159\u00e1d\u00e1n\u00ed zaji\u0161\u0165uje, \u017ee poruchy jsou izolov\u00e1ny v m\u00edst\u011b, kter\u00e9 je nejbl\u00ed\u017ee jejich v\u00fdskytu, a zachov\u00e1v\u00e1 nap\u00e1jen\u00ed nezasa\u017een\u00fdch obvod\u016f.<\/p>\n<h3>5.3 Specifikace p\u0159ipojen\u00ed a svorek<\/h3>\n<p>P\u0159\u00edstroj m\u00e1 dv\u011b mo\u017enosti p\u0159ipojen\u00ed shora i zespodu, co\u017e umo\u017e\u0148uje r\u016fzn\u00e9 konfigurace instalace. Specifikace svorek umo\u017e\u0148uj\u00ed:<\/p>\n<ul>\n<li>Kabelov\u00e9 p\u0159\u00edpojky do 35 mm\u00b2 (18-2 AWG)<\/li>\n<li>Kol\u00edkov\u00e9 p\u0159\u00edpojnice do 16 mm\u00b2 (18-5 AWG)<\/li>\n<\/ul>\n<p>V\u0161echny svorky maj\u00ed stupe\u0148 kryt\u00ed IP20, co\u017e zaji\u0161\u0165uje ochranu proti p\u0159ibl\u00ed\u017een\u00ed prst\u016f a z\u00e1rove\u0148 zachov\u00e1v\u00e1 p\u0159\u00edstupnost pro instalaci a \u00fadr\u017ebu.<\/p>\n<h2>6. V\u00fdkonnostn\u00ed a spolehlivostn\u00ed vlastnosti VML01 RCCB<\/h2>\n<h3>6.1 Odolnost v\u016f\u010di \u017eivotn\u00edmu prost\u0159ed\u00ed<\/h3>\n<p>VML01 RCCB je navr\u017een tak, aby spolehliv\u011b fungoval v \u0161irok\u00e9m rozsahu teplot:<\/p>\n<ul>\n<li><strong>Provozn\u00ed teplota:<\/strong> -25\u00b0C a\u017e 55\u00b0C (s denn\u00edm pr\u016fm\u011brem \u226435\u00b0C)<\/li>\n<li><strong>Teplota skladov\u00e1n\u00ed:<\/strong> -40 \u00b0C a\u017e 70 \u00b0C<\/li>\n<\/ul>\n<p>Tato tepeln\u00e1 odolnost zaji\u0161\u0165uje konzistentn\u00ed provoz v r\u016fzn\u00fdch instala\u010dn\u00edch prost\u0159ed\u00edch, od chladn\u00fdch pr\u016fmyslov\u00fdch prost\u0159ed\u00ed a\u017e po tepl\u00e9 u\u017eitkov\u00e9 m\u00edstnosti.<\/p>\n<h3>6.2 Provozn\u00ed \u017eivotnost<\/h3>\n<p>S elektrickou i mechanickou \u017eivotnost\u00ed \u2265 2000 operac\u00ed poskytuje VML01 RCCB dlouhodobou spolehlivost a sni\u017euje n\u00e1roky na \u00fadr\u017ebu. Tato prodlou\u017een\u00e1 provozn\u00ed \u017eivotnost znamen\u00e1 sn\u00ed\u017een\u00ed n\u00e1klad\u016f na v\u00fdm\u011bnu a zv\u00fd\u0161en\u00ed spolehlivosti syst\u00e9mu.<\/p>\n<h3>6.3 Indikace poruchy<\/h3>\n<p>VML01 RCCB obsahuje vestav\u011bn\u00fd indik\u00e1tor poruchov\u00e9ho proudu, kter\u00fd vizu\u00e1ln\u011b potvrzuje, \u017ee do\u0161lo k vypnut\u00ed v d\u016fsledku poruchy rezidu\u00e1ln\u00edho proudu. Tato funkce urychluje \u0159e\u0161en\u00ed probl\u00e9m\u016f a minimalizuje prostoje p\u0159i odstra\u0148ov\u00e1n\u00ed poruch.<\/p>\n<h2>7. Dodr\u017eov\u00e1n\u00ed p\u0159edpis\u016f a certifikace<\/h2>\n<p>VML01 RCCB je vyroben v souladu s normou IEC\/EN 61008-1, co\u017e zaru\u010duje, \u017ee spl\u0148uje mezin\u00e1rodn\u011b uzn\u00e1van\u00e9 po\u017eadavky na proudov\u00e9 chr\u00e1ni\u010de bez integrovan\u00e9 nadproudov\u00e9 ochrany. Tato shoda zaru\u010duje, \u017ee p\u0159\u00edstroj poskytuje spolehlivou ochranu v souladu s celosv\u011btov\u00fdmi bezpe\u010dnostn\u00edmi normami.<\/p>\n<h2>8. Pro\u010d si pro svou elektrickou instalaci vybrat VML01 RCCB?<\/h2>\n<h3>8.1 Komplexn\u00ed ochrana<\/h3>\n<p>VML01 RCCB poskytuje v\u00edcevrstvou ochranu p\u0159ed \u00farazem elektrick\u00fdm proudem p\u0159i nep\u0159\u00edm\u00e9m dotyku, p\u0159\u00edm\u00e9m dotyku a nebezpe\u010d\u00ed po\u017e\u00e1ru v d\u016fsledku poruchy izolace. Jeho rozmanit\u00e9 mo\u017enosti citlivosti a schopnosti detekce tvaru vlny zaji\u0161\u0165uj\u00ed vhodnou ochranu pro jakoukoli aplikaci.<\/p>\n<h3>8.2 V\u0161estrannost a p\u0159izp\u016fsobivost<\/h3>\n<p>D\u00edky v\u00edce p\u00f3lov\u00fdm konfigurac\u00edm (2P, 4P), jmenovit\u00fdm proud\u016fm (16A a\u017e 100A) a prah\u016fm citlivosti (10mA a\u017e 300mA) lze RCCB VML01 p\u0159esn\u011b p\u0159izp\u016fsobit specifick\u00fdm po\u017eadavk\u016fm na instalaci v obytn\u00fdch, komer\u010dn\u00edch a pr\u016fmyslov\u00fdch prost\u0159ed\u00edch.<\/p>\n<h3>8.3 Spolehlivost a trvanlivost<\/h3>\n<p>\u0158\u00eddic\u00ed jednotka VML01 RCCB je navr\u017eena pro prodlou\u017eenou provozn\u00ed \u017eivotnost a konzistentn\u00ed v\u00fdkon v n\u00e1ro\u010dn\u00fdch podm\u00ednk\u00e1ch prost\u0159ed\u00ed a poskytuje spolehlivou ochranu, kter\u00e1 minimalizuje po\u017eadavky na \u00fadr\u017ebu a zvy\u0161uje spolehlivost syst\u00e9mu.<\/p>\n<h3>8.4 Flexibilita instalace<\/h3>\n<p>Syst\u00e9m mont\u00e1\u017ee na li\u0161tu DIN, univerz\u00e1ln\u00ed p\u0159ipojen\u00ed svorek a kompaktn\u00ed rozm\u011bry za\u0159\u00edzen\u00ed usnad\u0148uj\u00ed instalaci do r\u016fzn\u00fdch konfigurac\u00ed rozv\u00e1d\u011b\u010d\u016f, co\u017e zjednodu\u0161uje nov\u00e9 instalace i modernizace syst\u00e9mu.<\/p>\n<h2>9.VML01 2P Rozm\u011br proudov\u00e9ho chr\u00e1ni\u010de (RCCB)<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-13918\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-2P-Residual-Current-Operated-Circuit-Breaker-RCCB-Dimension.webp\" alt=\"VML01 2P Residual Current Operated Circuit Breaker (RCCB) Dimension\" width=\"800\" height=\"260\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-2P-Residual-Current-Operated-Circuit-Breaker-RCCB-Dimension.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-2P-Residual-Current-Operated-Circuit-Breaker-RCCB-Dimension-300x98.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-2P-Residual-Current-Operated-Circuit-Breaker-RCCB-Dimension-768x250.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-2P-Residual-Current-Operated-Circuit-Breaker-RCCB-Dimension-18x6.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-2P-Residual-Current-Operated-Circuit-Breaker-RCCB-Dimension-600x195.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h2>10. Z\u00e1v\u011br<\/h2>\n<p>Proudov\u00fd chr\u00e1ni\u010d VML01 p\u0159edstavuje z\u00e1kladn\u00ed sou\u010d\u00e1st modern\u00edch elektrick\u00fdch bezpe\u010dnostn\u00edch syst\u00e9m\u016f. D\u00edky detekci unikaj\u00edc\u00edho proudu a rychl\u00e9mu odpojen\u00ed posti\u017een\u00fdch obvod\u016f poskytuje kritickou ochranu p\u0159ed nebezpe\u010d\u00edm \u00farazu elektrick\u00fdm proudem a po\u017e\u00e1ru.<\/p>\n<p>D\u00edky r\u016fzn\u00fdm mo\u017enostem konfigurace, pokro\u010dil\u00fdm ochrann\u00fdm funkc\u00edm a robustn\u00ed konstrukci poskytuje VML01 RCCB komplexn\u00ed bezpe\u010dnost pro elektrick\u00e9 instalace v obytn\u00fdch, komer\u010dn\u00edch a pr\u016fmyslov\u00fdch aplikac\u00edch. A\u0165 u\u017e chr\u00e1n\u00ed citliv\u00e1 za\u0159\u00edzen\u00ed, zabezpe\u010duje obvody v koupeln\u00e1ch nebo zabra\u0148uje nebezpe\u010d\u00ed po\u017e\u00e1ru v pr\u016fmyslov\u00fdch za\u0159\u00edzen\u00edch, VML01 RCCB nab\u00edz\u00ed spolehlivou ochranu v souladu s normami, kter\u00e1 zachov\u00e1v\u00e1 bezpe\u010dnost lid\u00ed i integritu syst\u00e9mu.<\/p>\n<p>Chcete-li z\u00edskat dal\u0161\u00ed informace nebo technickou podporu t\u00fdkaj\u00edc\u00ed se VML01 RCCB, obra\u0165te se na n\u00e1\u0161 t\u00fdm odborn\u00edk\u016f, kter\u00fd v\u00e1m pom\u016f\u017ee s v\u00fdb\u011brem optim\u00e1ln\u00ed konfigurace pro va\u0161e konkr\u00e9tn\u00ed po\u017eadavky na aplikaci.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"markdown\">\n<p>Proudov\u00fd chr\u00e1ni\u010d VIOX VML01 2P (RCCB) nab\u00edz\u00ed vynikaj\u00edc\u00ed elektrickou bezpe\u010dnost pro obytn\u00e9, komer\u010dn\u00ed a pr\u016fmyslov\u00e9 aplikace. Tento RCCB magnetick\u00e9ho typu (IEC\/EN 61008-1) chr\u00e1n\u00ed p\u0159ed \u00farazem elektrick\u00fdm proudem a nebezpe\u010d\u00edm po\u017e\u00e1ru t\u00edm, \u017ee detekuje \u00fanik zemn\u00edho proudu. K dispozici jsou typy AC a A s citlivost\u00ed od 10 mA do 300 mA.<\/p>\n<\/div>","protected":false},"featured_media":13917,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[131],"product_tag":[],"class_list":{"0":"post-13916","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-rccb","7":"desktop-align-left","8":"tablet-align-left","9":"mobile-align-left","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product\/13916","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/comments?post=13916"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media\/13917"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media?parent=13916"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product_brand?post=13916"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product_cat?post=13916"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/product_tag?post=13916"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}