{"id":21108,"date":"2025-12-30T23:00:14","date_gmt":"2025-12-30T15:00:14","guid":{"rendered":"https:\/\/viox.com\/?p=21108"},"modified":"2025-12-30T23:00:16","modified_gmt":"2025-12-30T15:00:16","slug":"abandoned-electrical-outlets-renovation-code-guide","status":"publish","type":"post","link":"https:\/\/test.viox.com\/cs\/abandoned-electrical-outlets-renovation-code-guide\/","title":{"rendered":"Jak nakl\u00e1dat s opu\u0161t\u011bn\u00fdmi elektrick\u00fdmi z\u00e1suvkami b\u011bhem rekonstrukce domu: \u0158e\u0161en\u00ed v souladu s p\u0159edpisy (2026)"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>Skryt\u00e9 nebezpe\u010d\u00ed za va\u0161\u00edm snem o rekonstrukci<\/h2>\n<p>Obvykle se to stane v \u201cDen demolice\u201d.\u201d<\/p>\n<p>Strhli jste ty mastn\u00e9 star\u00e9 kuchy\u0148sk\u00e9 sk\u0159\u00ed\u0148ky. Prostor vypad\u00e1 otev\u0159en\u00fd, \u010dist\u00fd a p\u0159ipraven\u00fd pro va\u0161i modern\u00ed designovou vizi. Ale tam, uprost\u0159ed toho, co by m\u011bla b\u00fdt hladk\u00e1 st\u011bna, na v\u00e1s z\u00edr\u00e1 zapr\u00e1\u0161en\u00e1 b\u00e9\u017eov\u00e1 elektrick\u00e1 z\u00e1suvka.<\/p>\n<p>Je na \u0161patn\u00e9m m\u00edst\u011b. Je o\u0161kliv\u00e1. A blokuje nov\u00e9 uspo\u0159\u00e1d\u00e1n\u00ed sk\u0159\u00edn\u011bk.<\/p>\n<p>Nutk\u00e1n\u00ed je ohromn\u00e9: <em>\u201cProst\u011b odpoj\u00edm z\u00e1suvku, zalep\u00edm dr\u00e1ty, nacpu je do d\u00edry a zakryju s\u00e1drokartonem. Sejde z o\u010d\u00ed, sejde z mysli.\u201d<\/em><\/p>\n<p><strong>Stop.<\/strong> Odlo\u017ete \u0161pachtli.<\/p>\n<p>To, co se chyst\u00e1te ud\u011blat, nen\u00ed jen poru\u0161en\u00ed p\u0159edpis\u016f \u2013 je to potenci\u00e1ln\u00ed riziko po\u017e\u00e1ru, kter\u00e9 m\u016f\u017ee z\u016fstat skryt\u00e9 po cel\u00e1 l\u00e9ta. V elektrotechnice je \u201cpoh\u0159b\u00edv\u00e1n\u00ed\u201d spojovac\u00ed krabice kardin\u00e1ln\u00ed h\u0159\u00edch, kter\u00fd poru\u0161uje <a href=\"https:\/\/test.viox.com\/cs\/nec-code-for-junction-boxes\/\">NEC 314.29<\/a> a v\u00e1\u017en\u011b ohro\u017euje v\u00e1\u0161 domov. Zde je d\u016fvod, pro\u010d je toto skryt\u00e9 dr\u00e1tov\u00e9 spojen\u00ed nebezpe\u010dn\u00e9, a jak nechat tuto necht\u011bnou z\u00e1suvku zmizet <em>spr\u00e1vnou<\/em> zp\u016fsobem.<\/p>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/Exposed-electrical-junction-box-in-kitchen-renovation-with-VIOX-old-work-electrical-box-and-professional-tools.webp\" alt=\"Exposed electrical junction box in kitchen renovation with VIOX old work electrical box and professional tools\" \/><figcaption style=\"font-style: italic; color: #555; text-align: center; margin-top: 8px; font-size: 0.9em;\">Obr\u00e1zek 1: Odkryt\u00e1 elektrick\u00e1 spojovac\u00ed krabice b\u011bhem rekonstrukce kuchyn\u011b s pou\u017eit\u00edm n\u00e1stroj\u016f VIOX a star\u00e9 krabice.<\/figcaption><\/figure>\n<h2>Pro\u010d poh\u0159b\u00edv\u00e1n\u00ed spojovac\u00edch krabic poru\u0161uje NEC a vytv\u00e1\u0159\u00ed riziko po\u017e\u00e1ru<\/h2>\n<p>N\u00e1rodn\u00ed elektrotechnick\u00fd p\u0159edpis (NEC) Odd\u00edl 314.29 stanov\u00ed z\u00e1kladn\u00ed bezpe\u010dnostn\u00ed po\u017eadavek: <strong>V\u0161echny spojovac\u00ed krabice, t\u011blesa trubek a \u0161achty mus\u00ed b\u00fdt instalov\u00e1ny tak, aby kabel\u00e1\u017e v nich obsa\u017een\u00e1 mohla b\u00fdt zp\u0159\u00edstupn\u011bna bez odstran\u011bn\u00ed jak\u00e9koli \u010d\u00e1sti budovy.<\/strong><\/p>\n<p>Nejedn\u00e1 se o byrokratickou z\u00e1t\u011b\u017e \u2013 je to protipo\u017e\u00e1rn\u00ed ochrana zalo\u017een\u00e1 na fyzice.<\/p>\n<h3>Tepeln\u00e1 cyklick\u00e1 \u010dasovan\u00e1 bomba<\/h3>\n<p>Elektrick\u00e9 spoje \u2013 a\u0165 u\u017e se jedn\u00e1 o kroucen\u00e9 dr\u00e1tov\u00e9 matice nebo \u0161roubov\u00e9 svorky \u2013 nejsou statick\u00e9. Existuj\u00ed v neust\u00e1l\u00e9m cyklu rozp\u00edn\u00e1n\u00ed a smr\u0161\u0165ov\u00e1n\u00ed:<\/p>\n<ol>\n<li><strong>Proudov\u00e9 toky<\/strong> \u2192 Dr\u00e1t se m\u00edrn\u011b zah\u0159eje<\/li>\n<li><strong>Proud se zastav\u00ed<\/strong> \u2192 Dr\u00e1t vychladne<\/li>\n<li><strong>V\u00fdsledek<\/strong> \u2192 Mikroskopick\u00e9 uvol\u0148ov\u00e1n\u00ed v pr\u016fb\u011bhu m\u011bs\u00edc\u016f a let<\/li>\n<\/ol>\n<p>Toto tepeln\u00e9 cyklov\u00e1n\u00ed p\u016fsob\u00ed jako neviditeln\u00e9 prsty, kter\u00e9 pomalu uvol\u0148uj\u00ed va\u0161e spojen\u00ed. Kdy\u017e se spojen\u00ed uvoln\u00ed, elektrick\u00fd odpor se zv\u00fd\u0161\u00ed. Vy\u0161\u0161\u00ed odpor generuje v\u00edce tepla. Nakonec elekt\u0159ina za\u010dne p\u0159eskakovat mezeru.<\/p>\n<p>V p\u0159\u00edstupn\u00e9 z\u00e1suvce uc\u00edt\u00edte z\u00e1pach sp\u00e1len\u00e9ho plastu nebo uvid\u00edte zbarvenou \u010deln\u00ed desku. V poh\u0159ben\u00e9 spojovac\u00ed krabici? P\u0159eskakov\u00e1n\u00ed pokra\u010duje ti\u0161e za va\u0161\u00ed st\u011bnou a zah\u0159\u00edv\u00e1 such\u00e9 d\u0159ev\u011bn\u00e9 sloupky zevnit\u0159, dokud nedojde k zap\u00e1len\u00ed.<\/p>\n<h3>Statistiky po\u017e\u00e1r\u016f z re\u00e1ln\u00e9ho sv\u011bta<\/h3>\n<p>Podle N\u00e1rodn\u00ed asociace po\u017e\u00e1rn\u00ed ochrany jsou elektrick\u00e9 poruchy a z\u00e1vady p\u0159\u00ed\u010dinou odhadem 13 % po\u017e\u00e1r\u016f obytn\u00fdch budov ro\u010dn\u011b. Skryt\u00e9 spojovac\u00ed krabice p\u0159edstavuj\u00ed v\u00fdznamnou \u010d\u00e1st t\u011bchto incident\u016f, proto\u017ee eliminuj\u00ed v\u010dasn\u00e9 varovn\u00e9 sign\u00e1ly, kter\u00e9 by vedly k oprav\u011b p\u0159ed katastrof\u00e1ln\u00edm selh\u00e1n\u00edm.<\/p>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/Technical-cutaway-diagram-showing-electrical-fire-hazard-from-buried-junction-box-versus-code-compliant-accessible-installation-with-VIOX-safety-annotation.webp\" alt=\"Technical cutaway diagram showing electrical fire hazard from buried junction box versus code-compliant accessible installation with VIOX safety annotation\" \/><figcaption style=\"font-style: italic; color: #555; text-align: center; margin-top: 8px; font-size: 0.9em;\">Obr\u00e1zek 2: Anal\u00fdza rizik po\u017e\u00e1ru zp\u016fsoben\u00fdch poh\u0159ben\u00fdmi spojovac\u00edmi krabicemi ve srovn\u00e1n\u00ed s instalacemi, kter\u00e9 jsou v souladu s p\u0159edpisy a jsou p\u0159\u00edstupn\u00e9.<\/figcaption><\/figure>\n<h2>Pochopen\u00ed topologie obvodu: Konec b\u011bhu vs. \u0159et\u011bzov\u00e9 zapojen\u00ed<\/h2>\n<p>P\u0159ed st\u0159\u00edh\u00e1n\u00edm jak\u00fdchkoli dr\u00e1t\u016f mus\u00edte odpov\u011bd\u011bt na z\u00e1sadn\u00ed ot\u00e1zku: <strong>Je tato z\u00e1suvka slep\u00e1 nebo je sou\u010d\u00e1st\u00ed v\u011bt\u0161\u00edho obvodu?<\/strong><\/p>\n<h3>Typy konfigurace obvodu<\/h3>\n<table style=\"width: 100%; border-collapse: collapse; text-align: left; margin-bottom: 20px;\" border=\"1\" cellspacing=\"0\" cellpadding=\"8\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>Typ konfigurace<\/th>\n<th>Po\u010det vodi\u010d\u016f v krabici<\/th>\n<th>Charakteristika<\/th>\n<th>Bezpe\u010dn\u00e9 odpojen\u00ed?<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Konec b\u011bhu<\/strong><\/td>\n<td>Jeden kabel (2-3 vodi\u010de)<\/td>\n<td>Nap\u00e1jen\u00ed kon\u010d\u00ed v t\u00e9to z\u00e1suvce<\/td>\n<td>Ano, ovliv\u0148uje pouze tuto z\u00e1suvku<\/td>\n<\/tr>\n<tr>\n<td><strong>St\u0159ed b\u011bhu (\u0159et\u011bzov\u00e9 zapojen\u00ed)<\/strong><\/td>\n<td>Dva nebo v\u00edce kabel\u016f<\/td>\n<td>Nap\u00e1jen\u00ed proch\u00e1z\u00ed do navazuj\u00edc\u00edch z\u00e1suvek<\/td>\n<td>Ne, p\u0159eru\u0161\u00ed cel\u00fd obvod<\/td>\n<\/tr>\n<tr>\n<td><strong>Spojovac\u00ed\/spojovac\u00ed bod<\/strong><\/td>\n<td>V\u00edce kabel\u016f<\/td>\n<td>\u017d\u00e1dn\u00e1 z\u00e1suvka, pouze dr\u00e1tov\u00e9 spoje<\/td>\n<td>Nikdy \u2013 mus\u00ed z\u016fstat p\u0159\u00edstupn\u00e9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>V\u011bt\u0161ina kuchy\u0148sk\u00fdch a ob\u00fdvac\u00edch pokojov\u00fdch z\u00e1suvek pou\u017e\u00edv\u00e1 \u0159et\u011bzov\u00e9 zapojen\u00ed, kde nap\u00e1jen\u00ed proud\u00ed <em>skrz<\/em> ka\u017ed\u00e1 krabice do dal\u0161\u00ed z\u00e1suvky. Pokud se ke krabici uprost\u0159ed b\u011bhu chov\u00e1te jako ke slep\u00e9 \u2013 p\u0159est\u0159ihnete dr\u00e1ty a poh\u0159b\u00edte je \u2013 p\u0159eru\u0161\u00edte nap\u00e1jen\u00ed v\u0161ech navazuj\u00edc\u00edch za\u0159\u00edzen\u00ed.<\/p>\n<p>Najednou zhasne va\u0161e ledni\u010dka. Sel\u017eou sv\u011btla na chodb\u011b. Nepoh\u0159bili jste jen krabici; zni\u010dili jste elektrickou s\u00ed\u0165 sv\u00e9ho domova.<\/p>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/Electrical-wiring-diagram-comparing-end-of-run-versus-daisy-chain-middle-of-run-outlet-configurations-with-VIOX-branding.webp\" alt=\"Electrical wiring diagram comparing end of run versus daisy chain middle of run outlet configurations with VIOX branding\" \/><figcaption style=\"font-style: italic; color: #555; text-align: center; margin-top: 8px; font-size: 0.9em;\">Obr\u00e1zek 3: Sch\u00e9ma zapojen\u00ed porovn\u00e1vaj\u00edc\u00ed konfigurace Konec b\u011bhu vs. \u0159et\u011bzov\u00e9 zapojen\u00ed (St\u0159ed b\u011bhu).<\/figcaption><\/figure>\n<h2>T\u0159i \u0159e\u0161en\u00ed pro opu\u0161t\u011bn\u00e9 z\u00e1suvky, kter\u00e1 jsou v souladu s p\u0159edpisy<\/h2>\n<p>Vzhledem k tomu, \u017ee NEC 314.29 zakazuje poh\u0159b\u00edv\u00e1n\u00ed spoj\u016f, m\u00e1te t\u0159i leg\u00e1ln\u00ed mo\u017enosti. Zde je srovn\u00e1n\u00ed:<\/p>\n<table style=\"width: 100%; border-collapse: collapse; text-align: left; margin-bottom: 20px;\" border=\"1\" cellspacing=\"0\" cellpadding=\"8\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>\u0158e\u0161en\u00ed<\/th>\n<th>Obt\u00ed\u017enost<\/th>\n<th>N\u00e1klady<\/th>\n<th>Estetika<\/th>\n<th>Nejlep\u0161\u00ed pro<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Kompletn\u00ed p\u0159epojen\u00ed<\/strong><\/td>\n<td>9\/10<\/td>\n<td>$$$<\/td>\n<td>10\/10<\/td>\n<td>Pouze z\u00e1suvky na konci b\u011bhu<\/td>\n<\/tr>\n<tr>\n<td><strong>P\u0159em\u00edst\u011bn\u00ed na p\u0159\u00edstupn\u00e9 m\u00edsto<\/strong><\/td>\n<td>6\/10<\/td>\n<td>$$<\/td>\n<td>8\/10<\/td>\n<td>St\u0159ed b\u011bhu s nedalekou sk\u0159\u00ed\u0148kou<\/td>\n<\/tr>\n<tr>\n<td><strong>Instalace kryc\u00ed desky<\/strong><\/td>\n<td>2\/10<\/td>\n<td>$<\/td>\n<td>5\/10<\/td>\n<td>Jak\u00e9koli p\u0159\u00edstupn\u00e9 m\u00edsto<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\u0158e\u0161en\u00ed 1: Kompletn\u00ed p\u0159epojen\u00ed obvodu (Profesion\u00e1ln\u00ed metoda)<\/h3>\n<p><strong>Obt\u00ed\u017enost:<\/strong> 9\/10 | <strong>Estetika:<\/strong> 10\/10 | <strong>Trval\u00e9:<\/strong> Ano<\/p>\n<p>Toto je jedin\u00e1 metoda, kter\u00e1 zcela eliminuje necht\u011bnou spojovac\u00ed krabici. Proces vy\u017eaduje:<\/p>\n<ol>\n<li>P\u0159\u00edstup do podkrov\u00ed, suter\u00e9nu nebo prol\u00e9zac\u00edho prostoru<\/li>\n<li>Sledov\u00e1n\u00ed kabelu zp\u011bt k p\u0159ed\u0159azen\u00e9 spojovac\u00ed krabici<\/li>\n<li>Odpojte necht\u011bn\u00fd obvod z\u00e1suvky<\/li>\n<li>Pokud je sou\u010d\u00e1st\u00ed \u0159et\u011bzov\u00e9ho zapojen\u00ed, ve\u010fte nov\u00fd kabel z krabice proti proudu do krabice po proudu, \u010d\u00edm\u017e obejdete necht\u011bn\u00e9 m\u00edsto<\/li>\n<li>Vyspravte a opravte opu\u0161t\u011bn\u00fd otvor<\/li>\n<\/ol>\n<p><strong>V\u00fdsledek:<\/strong> Necht\u011bn\u00e9 um\u00edst\u011bn\u00ed z\u00e1suvky je zcela nefunk\u010dn\u00ed. M\u016f\u017eete vyspravit, nat\u0159\u00edt a instalovat sk\u0159\u00ed\u0148ky bez jak\u00fdchkoli omezen\u00ed.<\/p>\n<p><strong>Kdy pou\u017e\u00edt:<\/strong> Praktick\u00e9 pouze pro z\u00e1suvky na konci veden\u00ed nebo kdy\u017e m\u00e1te jasn\u00fd p\u0159\u00edstup do dutin stropu\/podlahy. Nedoporu\u010duje se pro z\u00e1suvky uprost\u0159ed veden\u00ed, pokud v\u00e1m nevad\u00ed v\u00e9st nov\u00fd kabel p\u0159es hotov\u00e9 st\u011bny.<\/p>\n<h3>\u0158e\u0161en\u00ed 2: P\u0159em\u00edst\u011bn\u00ed na p\u0159\u00edstupn\u00e9 m\u00edsto (Metoda star\u00e9 pr\u00e1ce)<\/h3>\n<p><strong>Obt\u00ed\u017enost:<\/strong> 6\/10 | <strong>Estetika:<\/strong> 8\/10 | <strong>V souladu s p\u0159edpisy:<\/strong> Ano<\/p>\n<p>Pokud krabice mus\u00ed z\u016fstat funk\u010dn\u00ed, ale jej\u00ed sou\u010dasn\u00e9 um\u00edst\u011bn\u00ed je problematick\u00e9, p\u0159em\u00edst\u011bn\u00ed nab\u00edz\u00ed kompromis:<\/p>\n<ol>\n<li>Vypn\u011bte nap\u00e1jen\u00ed na <a href=\"https:\/\/test.viox.com\/cs\/standard-breaker-sizes\/\">panel jisti\u010d\u016f<\/a><\/li>\n<li>Odpojte z\u00e1suvku a odstra\u0148te ji<\/li>\n<li>Opatrn\u011b vyt\u00e1hn\u011bte kabel na nedalek\u00e9 p\u0159\u00edstupn\u00e9 m\u00edsto (uvnit\u0159 sk\u0159\u00ed\u0148ky, v oblasti soklu nebo v p\u0159ilehl\u00e9 \u010d\u00e1sti st\u011bny)<\/li>\n<li>Vy\u0159\u00edzn\u011bte nov\u00fd otvor a nainstalujte <strong>VIOX pro starou pr\u00e1ci <a href=\"https:\/\/test.viox.com\/cs\/junction-box-manufacturer\/\">Junction Box<\/a><\/strong><\/li>\n<\/ol>\n<p><strong>Kl\u00ed\u010dov\u00e1 v\u00fdhoda krabic VIOX pro starou pr\u00e1ci:<\/strong> Tyto krabice pro rekonstrukce maj\u00ed nastaviteln\u00e9 mont\u00e1\u017en\u00ed \u00fachyty, kter\u00e9 se vyklop\u00ed za s\u00e1drokarton a pevn\u011b dr\u017e\u00ed bez nutnosti p\u0159\u00edstupu ke sloupk\u016fm. Instalace je minim\u00e1ln\u011b n\u00e1ro\u010dn\u00e1 na n\u00e1stroje a funguje v hotov\u00fdch st\u011bn\u00e1ch, kde nelze instalovat tradi\u010dn\u00ed krabice pro novou pr\u00e1ci.<\/p>\n<table style=\"width: 100%; border-collapse: collapse; text-align: left; margin-bottom: 20px;\" border=\"1\" cellspacing=\"0\" cellpadding=\"8\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>Typ spojovac\u00ed krabice<\/th>\n<th>Zp\u016fsob mont\u00e1\u017ee<\/th>\n<th>\u010casov\u00e1n\u00ed instalace<\/th>\n<th>Nejlep\u0161\u00ed p\u0159\u00edpad pou\u017eit\u00ed<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Nov\u00e1 pr\u00e1ce<\/strong><\/td>\n<td>P\u0159ibito ke sloupku<\/td>\n<td>P\u0159ed s\u00e1drokartonem<\/td>\n<td>Nov\u00e1 konstrukce<\/td>\n<\/tr>\n<tr>\n<td><strong>Star\u00e1 pr\u00e1ce (Rekonstrukce)<\/strong><\/td>\n<td>Pru\u017einov\u00e9 svorky nebo \u00fachyty<\/td>\n<td>Po s\u00e1drokartonu<\/td>\n<td>St\u00e1vaj\u00edc\u00ed st\u011bny<\/td>\n<\/tr>\n<tr>\n<td><strong>Krabice pro stropn\u00ed ventil\u00e1tor<\/strong><\/td>\n<td>Upevn\u011bno v\u00fdztuhou<\/td>\n<td>Bu\u010f<\/td>\n<td>Podpora t\u011b\u017ek\u00e9ho sv\u00edtidla<\/td>\n<\/tr>\n<tr>\n<td><strong>Odolnost proti pov\u011btrnostn\u00edm vliv\u016fm<\/strong><\/td>\n<td>Povrchov\u00e1 mont\u00e1\u017e<\/td>\n<td>Bu\u010f<\/td>\n<td>Venkovn\u00ed aplikace<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>V\u00fdsledek:<\/strong> Spoj z\u016fst\u00e1v\u00e1 v souladu s p\u0159edpisy a je p\u0159\u00edstupn\u00fd, ale je p\u0159esunut z cesty va\u0161emu designu \u2013 obvykle uvnit\u0159 sk\u0159\u00ed\u0148ky nebo bl\u00edzko podlahy, kde je pr\u00e1zdn\u00e1 kryc\u00ed deska m\u00e9n\u011b n\u00e1padn\u00e1.<\/p>\n<h3>\u0158e\u0161en\u00ed 3: Instalace pr\u00e1zdn\u00e9 kryc\u00ed desky (Poctiv\u00e1 metoda)<\/h3>\n<p><strong>Obt\u00ed\u017enost:<\/strong> 2\/10 | <strong>Estetika:<\/strong> 5\/10 | <strong>V souladu s p\u0159edpisy:<\/strong> Ano<\/p>\n<p>Toto je nejb\u011b\u017en\u011bj\u0161\u00ed \u0159e\u0161en\u00ed pro z\u00e1suvky uprost\u0159ed veden\u00ed, kter\u00e9 nelze snadno p\u0159em\u00edstit:<\/p>\n<ol>\n<li>Vypn\u011bte nap\u00e1jen\u00ed na jisti\u010di<\/li>\n<li>Odstra\u0148te z\u00e1suvku<\/li>\n<li>P\u0159ipojte vstupn\u00ed a v\u00fdstupn\u00ed vodi\u010de uvnit\u0159 krabice (p\u0159i zachov\u00e1n\u00ed \u0159et\u011bzov\u00e9ho zapojen\u00ed)<\/li>\n<li>Nainstalujte <strong>Pr\u00e1zdnou kryc\u00ed desku VIOX<\/strong> p\u0159es krabici<\/li>\n<\/ol>\n<p><strong>Z\u00e1sadn\u00ed pravidlo:<\/strong> Pr\u00e1zdn\u00e1 deska mus\u00ed z\u016fstat viditeln\u00e1 a p\u0159\u00edstupn\u00e1. Nesm\u00edte:<\/p>\n<ul>\n<li>Oblo\u017eit ji dla\u017edicemi<\/li>\n<li>Instalovat p\u0159es ni trval\u00e9 sk\u0159\u00ed\u0148ky<\/li>\n<li>Nat\u0159\u00edt ji stejnou barvou jako st\u011bnu, abyste ji skryli (nedoporu\u010duje se, ale nen\u00ed v\u00fdslovn\u011b zak\u00e1z\u00e1no)<\/li>\n<\/ul>\n<p>Deska mus\u00ed b\u00fdt odn\u00edmateln\u00e1 \u0161roubov\u00e1kem pro budouc\u00ed \u00fadr\u017ebu nebo kontrolu.<\/p>\n<p><strong>V\u00fdhody pr\u00e1zdn\u00e9 desky VIOX:<\/strong><\/p>\n<ul>\n<li>Ni\u017e\u0161\u00ed profil ne\u017e standardn\u00ed desky pro dodavatele<\/li>\n<li>Mont\u00e1\u017en\u00ed \u0161rouby s barevn\u00fdm slad\u011bn\u00edm<\/li>\n<li>Matn\u00fd povrch, kter\u00fd sp\u00ed\u0161e spl\u00fdv\u00e1, ne\u017e vy\u010dn\u00edv\u00e1<\/li>\n<li>Materi\u00e1l odoln\u00fd v\u016f\u010di UV z\u00e1\u0159en\u00ed, kter\u00fd ne\u017eloutne<\/li>\n<\/ul>\n<p><strong>V\u00fdsledek:<\/strong> P\u0159ipojen\u00ed z\u016fst\u00e1v\u00e1 bezpe\u010dn\u00e9 a v souladu s p\u0159edpisy. I kdy\u017e nen\u00ed neviditeln\u00e1, kvalitn\u00ed pr\u00e1zdn\u00e1 deska se st\u00e1v\u00e1 sp\u00ed\u0161e p\u0159\u00edstupov\u00fdm bodem pro \u00fadr\u017ebu ne\u017e o\u0161klivou skvrnou.<\/p>\n<h2>Technologie p\u0159ipojen\u00ed vodi\u010d\u016f: Pro\u010d z\u00e1le\u017e\u00ed na va\u0161\u00ed volb\u011b pro dlouhodobou bezpe\u010dnost<\/h2>\n<p>Kdy\u017e vytv\u00e1\u0159\u00edte nebo udr\u017eujete spoj, kter\u00fd nemus\u00ed b\u00fdt otev\u0159en v\u00edce ne\u017e 20 let, kvalita p\u0159ipojen\u00ed se st\u00e1v\u00e1 prvo\u0159adou. Zde se mnoho renovac\u00ed sv\u00e9pomoc\u00ed dopou\u0161t\u00ed kritick\u00fdch chyb.<\/p>\n<h3>Tradi\u010dn\u00ed dr\u00e1tov\u00e9 matice vs. pru\u017einov\u00e9 svorky<\/h3>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/Technical-comparison-diagram-of-traditional-wire-nuts-versus-VIOX-spring-clamp-terminal-connectors-showing-vibration-resistance-and-connection-reliability.webp\" alt=\"Technical comparison diagram of traditional wire nuts versus VIOX spring-clamp terminal connectors showing vibration resistance and connection reliability\" \/><figcaption style=\"font-style: italic; color: #555; text-align: center; margin-top: 8px; font-size: 0.9em;\">Obr\u00e1zek 4: Srovn\u00e1n\u00ed odolnosti proti vibrac\u00edm a spolehlivosti mezi tradi\u010dn\u00edmi dr\u00e1tov\u00fdmi maticemi a pru\u017einov\u00fdmi svorkami VIOX.<\/figcaption><\/figure>\n<table style=\"width: 100%; border-collapse: collapse; text-align: left; margin-bottom: 20px;\" border=\"1\" cellspacing=\"0\" cellpadding=\"8\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>Funkce<\/th>\n<th>Tradi\u010dn\u00ed dr\u00e1tov\u00e9 matice<\/th>\n<th>Pru\u017einov\u00e9 svorky VIOX<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Instalace<\/strong><\/td>\n<td>Zato\u010dte vodi\u010de, na\u0161roubujte matici<\/td>\n<td>Vlo\u017ete vodi\u010d, zav\u0159ete p\u00e1\u010dku<\/td>\n<\/tr>\n<tr>\n<td><strong>Mechanismus uchopen\u00ed<\/strong><\/td>\n<td>Ku\u017eelov\u00e1 pru\u017einov\u00e1 c\u00edvka<\/td>\n<td>Ploch\u00e1 pru\u017einov\u00e1 svorka<\/td>\n<\/tr>\n<tr>\n<td><strong>Tepeln\u00fd v\u00fdkon<\/strong><\/td>\n<td>M\u016f\u017ee se \u010dasem uvolnit<\/td>\n<td>Udr\u017eov\u00e1n konstantn\u00ed tlak<\/td>\n<\/tr>\n<tr>\n<td><strong>Odolnost proti vibrac\u00edm<\/strong><\/td>\n<td>M\u00edrn\u00e1<\/td>\n<td>Vynikaj\u00edc\u00ed<\/td>\n<\/tr>\n<tr>\n<td><strong>Znovupou\u017eitelnost<\/strong><\/td>\n<td>Doporu\u010deno pro jednor\u00e1zov\u00e9 pou\u017eit\u00ed<\/td>\n<td>Pln\u011b opakovan\u011b pou\u017eiteln\u00e9<\/td>\n<\/tr>\n<tr>\n<td><strong>Vizu\u00e1ln\u00ed ov\u011b\u0159en\u00ed<\/strong><\/td>\n<td>Nepr\u016fhledn\u00e9 \u2013 nelze ov\u011b\u0159it p\u0159ipojen\u00ed<\/td>\n<td>Pr\u016fhledn\u00e9 pouzdro ukazuje zasunut\u00ed vodi\u010de<\/td>\n<\/tr>\n<tr>\n<td><strong>K\u00f3d Souladu<\/strong><\/td>\n<td>Ano (UL Listed)<\/td>\n<td>Ano (UL Listed)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Pro\u010d pru\u017einov\u00e9 svorky vynikaj\u00ed v aplikac\u00edch typu \u201cnastav a zapome\u0148\u201d<\/h3>\n<p>Pro instala\u010dn\u00ed krabice um\u00edst\u011bn\u00e9 za sk\u0159\u00edn\u011bmi nebo na jin\u00fdch trval\u00fdch m\u00edstech, <strong>Pru\u017einov\u00e9 svorky VIOX<\/strong> (podobn\u00e9 p\u00e1kov\u00fdm konektor\u016fm Wago) nab\u00edzej\u00ed z\u0159eteln\u00e9 v\u00fdhody:<\/p>\n<p><strong>Technologie konstantn\u00edho tlaku:<\/strong> Vnit\u0159n\u00ed ploch\u00e1 pru\u017eina vyv\u00edj\u00ed trvalou s\u00edlu na vodi\u010d. Pokud se m\u011b\u010f smr\u0161\u0165uje b\u011bhem poklesu teplot v zim\u011b, pru\u017eina automaticky kompenzuje t\u00edm, \u017ee se svorka ut\u00e1hne. Neexistuje \u017e\u00e1dn\u00fd uvol\u0148ovac\u00ed mechanismus.<\/p>\n<p><strong>Odolnost proti vibrac\u00edm:<\/strong> V kuchyn\u00edch s bouchaj\u00edc\u00edmi z\u00e1suvkami, drti\u010di odpadu nebo my\u010dkami n\u00e1dob\u00ed, kter\u00e9 vytv\u00e1\u0159ej\u00ed neust\u00e1l\u00e9 vibrace, pru\u017einov\u00e9 svorky udr\u017euj\u00ed \u00fachop tam, kde se dr\u00e1tov\u00e9 matice mohou postupn\u011b uvol\u0148ovat.<\/p>\n<p><strong>Nulov\u00fd potenci\u00e1l pro vznik oblouku:<\/strong> Udr\u017eov\u00e1n\u00edm konstantn\u00edho kontaktn\u00edho tlaku po cel\u00e9 plo\u0161e vodi\u010de eliminuj\u00ed pru\u017einov\u00e9 svorky mikro-mezery, kter\u00e9 vedou ke vzniku oblouku a hromad\u011bn\u00ed tepla \u2013 prim\u00e1rn\u00edmu zdroji vzn\u00edcen\u00ed ve skryt\u00fdch instala\u010dn\u00edch krabic\u00edch.<\/p>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/VIOX-spring-clamp-terminal-connectors-being-installed-in-electrical-junction-box-showing-professional-wire-connection-method.webp\" alt=\"VIOX spring-clamp terminal connectors being installed in electrical junction box showing professional wire connection method\" \/><figcaption style=\"font-style: italic; color: #555; text-align: center; margin-top: 8px; font-size: 0.9em;\">Obr\u00e1zek 5: Profesion\u00e1ln\u00ed instalace pru\u017einov\u00fdch svorkovnic VIOX zaji\u0161\u0165uj\u00edc\u00ed bezpe\u010dn\u00e9 elektrick\u00e9 spojen\u00ed.<\/figcaption><\/figure>\n<h3>Osv\u011bd\u010den\u00e9 postupy p\u0159i instalaci<\/h3>\n<p>Bez ohledu na typ konektoru dodr\u017eujte tyto kritick\u00e9 kroky:<\/p>\n<ol>\n<li><strong>Spr\u00e1vn\u011b odizolujte vodi\u010d:<\/strong> 1\/2 palce pro dr\u00e1tov\u00e9 matice, dodr\u017eujte zna\u010den\u00ed svorek pro pru\u017einov\u00e9 svorky<\/li>\n<li><strong>\u017d\u00e1dn\u00e1 odkryt\u00e1 m\u011b\u010f:<\/strong> Ve\u0161ker\u00fd hol\u00fd vodi\u010d mus\u00ed b\u00fdt uvnit\u0159 konektoru<\/li>\n<li><strong>Tahov\u00e1 zkou\u0161ka:<\/strong> Ka\u017ed\u00fd vodi\u010d by m\u011bl odolat ta\u017en\u00e9 s\u00edle 10-15 liber bez pohybu<\/li>\n<li><strong>Spr\u00e1vn\u00e9 zapln\u011bn\u00ed krabice:<\/strong> NEC 314.16 omezuje po\u010det vodi\u010d\u016f na objem krabice \u2013 p\u0159epln\u011bn\u00ed zp\u016fsobuje hromad\u011bn\u00ed tepla<\/li>\n<li><strong>V\u0161e ozna\u010dte:<\/strong> Poznamenejte si podrobnosti o obvodu na krabici nebo uvnit\u0159 krytu pro budouc\u00ed pou\u017eit\u00ed<\/li>\n<\/ol>\n<table style=\"width: 100%; border-collapse: collapse; text-align: left; margin-bottom: 20px;\" border=\"1\" cellspacing=\"0\" cellpadding=\"8\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>M\u011b\u0159idlo dr\u00e1tu<\/th>\n<th>Po\u017eadovan\u00fd objem (kubick\u00e9 palce)<\/th>\n<th>Typick\u00e1 kapacita krabice<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>14 AWG<\/td>\n<td>2.0<\/td>\n<td>6-8 vodi\u010d\u016f v krabici o objemu 18 kubick\u00fdch palc\u016f<\/td>\n<\/tr>\n<tr>\n<td>12 AWG<\/td>\n<td>2.25<\/td>\n<td>5-7 vodi\u010d\u016f v krabici o objemu 18 kubick\u00fdch palc\u016f<\/td>\n<\/tr>\n<tr>\n<td>10 AWG<\/td>\n<td>2.5<\/td>\n<td>4-5 vodi\u010d\u016f v krabici o objemu 18 kubick\u00fdch palc\u016f<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em>Pozn\u00e1mka: Po\u010dty zahrnuj\u00ed zemn\u00edc\u00ed vodi\u010de, kabelov\u00e9 svorky a za\u0159\u00edzen\u00ed podle NEC 314.16(B)<\/em><\/p>\n<h2>Zvl\u00e1\u0161tn\u00ed aspekty pro venkovn\u00ed a vysoce vlhk\u00e9 lokality<\/h2>\n<p>Pokud je va\u0161e opu\u0161t\u011bn\u00e1 z\u00e1suvka um\u00edst\u011bna v koupeln\u011b, vn\u011bj\u0161\u00ed st\u011bn\u011b nebo venkovn\u00ed kuchyni, plat\u00ed dal\u0161\u00ed po\u017eadavky p\u0159edpis\u016f:<\/p>\n<h3><a href=\"https:\/\/test.viox.com\/cs\/what-is-nema\/\">NEMA<\/a> Hodnocen\u00ed pro instala\u010dn\u00ed krabice<\/h3>\n<table style=\"width: 100%; border-collapse: collapse; text-align: left; margin-bottom: 20px;\" border=\"1\" cellspacing=\"0\" cellpadding=\"8\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>Stupe\u0148 kryt\u00ed NEMA<\/th>\n<th>\u00darove\u0148 ochrany<\/th>\n<th>Aplikace<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>NEMA 1<\/strong><\/td>\n<td>Vnit\u0159n\u00ed, such\u00e9<\/td>\n<td>Standardn\u00ed interi\u00e9r<\/td>\n<\/tr>\n<tr>\n<td><strong>NEMA 3R<\/strong><\/td>\n<td>Venkovn\u00ed, odoln\u00e9 proti de\u0161ti<\/td>\n<td>Kryt\u00e9 venkovn\u00ed lokality<\/td>\n<\/tr>\n<tr>\n<td><strong>NEMA 4X<\/strong><\/td>\n<td>Vodot\u011bsn\u00e9, odoln\u00e9 proti korozi<\/td>\n<td>P\u0159\u00edm\u00e9 vystaven\u00ed pov\u011btrnostn\u00edm vliv\u016fm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Pro jakoukoli venkovn\u00ed instalaci instala\u010dn\u00ed krabice vy\u017eaduje NEC 300.5 dodate\u010dnou ochranu, v\u010detn\u011b spr\u00e1vn\u00e9 hloubky ulo\u017een\u00ed (minim\u00e1ln\u011b 18 palc\u016f pro tuh\u00e9 potrub\u00ed) a pou\u017eit\u00ed vodot\u011bsn\u00fdch konektor\u016f vodi\u010d\u016f s teplem smr\u0161titelnou bu\u017e\u00edrkou.<\/p>\n<p><strong>Kritick\u00e9 poru\u0161en\u00ed p\u0159edpis\u016f:<\/strong> Instala\u010dn\u00ed krabici nem\u016f\u017eete zakopat pod zem, a to ani ve vodot\u011bsn\u00e9m pouzd\u0159e, proto\u017ee to poru\u0161uje po\u017eadavek p\u0159\u00edstupnosti NEC 314.29. V\u0161echny body spojen\u00ed mus\u00ed b\u00fdt v nadzemn\u00edch p\u0159\u00edstupn\u00fdch pouzdrech.<\/p>\n<h2>Rozhodovac\u00ed r\u00e1mec: V\u00fdb\u011br metody \u0159e\u0161en\u00ed<\/h2>\n<p>Pou\u017eijte tuto logiku v\u00fdvojov\u00e9ho diagramu k ur\u010den\u00ed nejlep\u0161\u00edho p\u0159\u00edstupu:<\/p>\n<ul>\n<li><strong>Je z\u00e1suvka na konci b\u011bhu (do krabice vstupuje pouze jeden kabel)?<\/strong>\n<ul>\n<li>Ano: Zva\u017ete \u00fapln\u00e9 odstran\u011bn\u00ed (\u0159e\u0161en\u00ed 1)<\/li>\n<li>Ne: P\u0159ejd\u011bte k dal\u0161\u00ed ot\u00e1zce<\/li>\n<\/ul>\n<\/li>\n<li><strong>M\u00e1te p\u0159\u00edstup do stropn\u00ed\/podlahov\u00e9 dutiny nad\/pod?<\/strong>\n<ul>\n<li>Ano: P\u0159em\u00edst\u011bn\u00ed m\u016f\u017ee b\u00fdt praktick\u00e9 (\u0159e\u0161en\u00ed 2)<\/li>\n<li>Ne: P\u0159ejd\u011bte k dal\u0161\u00ed ot\u00e1zce<\/li>\n<\/ul>\n<\/li>\n<li><strong>Existuje p\u0159ilehl\u00e9 p\u0159\u00edstupn\u00e9 m\u00edsto (uvnit\u0159 sk\u0159\u00edn\u011b, pobl\u00ed\u017e podlahov\u00e9 li\u0161ty)?<\/strong>\n<ul>\n<li>Ano: Pou\u017eijte p\u0159em\u00edst\u011bn\u00ed pomoc\u00ed instala\u010dn\u00ed krabice VIOX Old Work Box (\u0159e\u0161en\u00ed 2)<\/li>\n<li>Ne: Nainstalujte pr\u00e1zdnou kryc\u00ed desku (\u0159e\u0161en\u00ed 3)<\/li>\n<\/ul>\n<\/li>\n<li><strong>Bude pr\u00e1zdn\u00e1 deska viditeln\u00e1 ve va\u0161em kone\u010dn\u00e9m n\u00e1vrhu?<\/strong>\n<ul>\n<li>Ano: Zva\u017ete dekorativn\u00ed pr\u00e1zdn\u00e9 desky VIOX v barevn\u011b slad\u011bn\u00e9m proveden\u00ed<\/li>\n<li>Ne: Standardn\u00ed pr\u00e1zdn\u00e1 deska je p\u0159ijateln\u00e1, pokud je skute\u010dn\u011b skryt\u00e1 n\u00e1bytkem (ale mus\u00ed z\u016fstat p\u0159\u00edstupn\u00e1)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2>Shrnut\u00ed: Zahrnut\u00ed bezpe\u010dnosti do va\u0161\u00ed rekonstrukce<\/h2>\n<p>Kdy\u017e b\u011bhem demolice objev\u00edte problematickou z\u00e1suvku:<\/p>\n<ol>\n<li><strong>Nikdy ji nezakop\u00e1vejte:<\/strong> Poru\u0161en\u00ed NEC 314.29 vytv\u00e1\u0159\u00ed po\u017e\u00e1rn\u00ed nebezpe\u010d\u00ed a neprojde kontrolou<\/li>\n<li><strong>Ov\u011b\u0159te topologii obvodu:<\/strong> Nep\u0159eru\u0161ujte \u0159et\u011bzov\u00e9 zapojen\u00ed, pokud nejste p\u0159ipraveni p\u0159epojit z\u00e1suvky za n\u00edm<\/li>\n<li><strong>Vyberte kvalitn\u00ed spojovac\u00ed materi\u00e1l:<\/strong> Pro trval\u00e9 instalace poskytuj\u00ed pru\u017einov\u00e9 svorky VIOX vynikaj\u00edc\u00ed dlouhodobou spolehlivost oproti tradi\u010dn\u00edm \u0161roubovac\u00edm spojk\u00e1m<\/li>\n<li><strong>Dokumentujte svou pr\u00e1ci:<\/strong> Po\u0159izujte fotografie, ozna\u010dujte obvody a zanech\u00e1vejte pozn\u00e1mky pro budouc\u00ed elektrik\u00e1\u0159e nebo majitele dom\u016f<\/li>\n<li><strong>V p\u0159\u00edpad\u011b pochybnost\u00ed si najm\u011bte licencovan\u00e9ho elektrik\u00e1\u0159e:<\/strong> Slo\u017eit\u00e9 p\u0159epojov\u00e1n\u00ed vy\u017eaduje odborn\u00e9 znalosti, aby se p\u0159ede\u0161lo vzniku nov\u00fdch rizik<\/li>\n<\/ol>\n<p>Rekonstrukce je o transformaci estetiky a funk\u010dnosti va\u0161eho domova. Skute\u010dn\u00e9 \u0159emesln\u00e9 zpracov\u00e1n\u00ed ale znamen\u00e1 nikdy neob\u011btovat bezpe\u010dnost vzhledu. Patn\u00e1ct minut, kter\u00e9 investujete do spr\u00e1vn\u00e9ho proveden\u00ed pr\u00e1ce s instala\u010dn\u00ed krabic\u00ed, by mohlo zabr\u00e1nit katastrof\u00e1ln\u00edmu po\u017e\u00e1ru v budoucnu.<\/p>\n<p>Spr\u00e1vn\u00e9 \u0159e\u0161en\u00ed nen\u00ed v\u017edy to nejrychlej\u0161\u00ed \u2013 je to to, kter\u00e9 chr\u00e1n\u00ed va\u0161i rodinu a spl\u0148uje profesion\u00e1ln\u00ed elektrotechnick\u00e9 normy. A\u0165 u\u017e si vyberete kompletn\u00ed p\u0159epojen\u00ed, p\u0159em\u00edst\u011bn\u00ed s komponenty VIOX Old Work nebo instalaci p\u0159\u00edstupn\u00e9 z\u00e1slepky, zvolte mo\u017enost, kter\u00e1 udr\u017e\u00ed v\u00e1\u0161 elektrick\u00fd syst\u00e9m bezpe\u010dn\u00fd, p\u0159\u00edstupn\u00fd a v souladu s p\u0159edpisy.<\/p>\n<p>Nechte dr\u00e1ty d\u00fdchat. Va\u0161e budouc\u00ed j\u00e1 v\u00e1m pod\u011bkuje.<\/p>\n<\/div>\n<div class=\"simg-pop-btn\" style=\"top: 6683.46px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 6683.46px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 419.828px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 419.828px; left: 14px; display: none;\"><\/div>","protected":false},"excerpt":{"rendered":"<p>The Hidden Danger Behind Your Renovation Dream It usually happens on &#8220;Demo Day.&#8221; You&#8217;ve ripped down those greasy old kitchen cabinets. The space looks open, clean, and ready for your modern design vision. But there, staring back at you from the middle of what should be a smooth wall, sits a dusty, beige electrical outlet. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":21109,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-21108","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts\/21108","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/comments?post=21108"}],"version-history":[{"count":1,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts\/21108\/revisions"}],"predecessor-version":[{"id":21110,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts\/21108\/revisions\/21110"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media\/21109"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media?parent=21108"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/categories?post=21108"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/tags?post=21108"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}