{"id":19943,"date":"2025-11-17T05:07:00","date_gmt":"2025-11-16T21:07:00","guid":{"rendered":"https:\/\/viox.com\/?p=19943"},"modified":"2025-11-14T11:07:50","modified_gmt":"2025-11-14T03:07:50","slug":"icu-wall-mccb-vs-acb-interrupting-capacity","status":"publish","type":"post","link":"https:\/\/test.viox.com\/cs\/icu-wall-mccb-vs-acb-interrupting-capacity\/","title":{"rendered":"St\u011bna JIP: Pro\u010d m\u016f\u017ee v\u00e1\u0161 MCCB explodovat tam, kde je ACB v bezpe\u010d\u00ed"},"content":{"rendered":"<div class=\"product-intro\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-19945\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Icu-Wall.webp\" alt=\"The Icu Wall\" width=\"800\" height=\"800\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Icu-Wall.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Icu-Wall-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Icu-Wall-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Icu-Wall-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Icu-Wall-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Icu-Wall-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Icu-Wall-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Posuzujete rozpo\u010det n\u00e1vrhu panelu. Specifikace vy\u017eaduje hlavn\u00ed jisti\u010d pro vstupn\u00ed veden\u00ed o proudu 2500 A. Naleznete dv\u011b mo\u017enosti:<\/p>\n<ul>\n<li><strong>Mo\u017enost A (<a href=\"https:\/\/test.viox.com\/cs\/mccb\/\">MCCB<\/a>):<\/strong> Levn\u00e9, kompaktn\u00ed a dimenzovan\u00e9 na 2500 A.<\/li>\n<li><strong>Mo\u017enost B (<a href=\"https:\/\/test.viox.com\/cs\/complete-guide-to-air-circuit-breakers-acb\/\">ACB<\/a>):<\/strong> Masivn\u00ed, objemn\u00e9 a p\u011btkr\u00e1t dra\u017e\u0161\u00ed.<\/li>\n<\/ul>\n<p>Ot\u00e1zka nevyhnuteln\u011b skon\u010d\u00ed na stole elektroin\u017een\u00fdra: <em>\u201cPro\u010d plat\u00edme tolik za ten objemn\u00fd, kdy\u017e ten levn\u011bj\u0161\u00ed m\u00e1 stejn\u00e9 nap\u011bt\u00ed a proud?\u201d<\/em><\/p>\n<p>Odpov\u011b\u010f je jednoduch\u00e1, ale na typov\u00e9m \u0161t\u00edtku neviditeln\u00e1: **Vyp\u00ednac\u00ed schopnost (Icu).**<\/p>\n<p>Neporovn\u00e1v\u00e1te schopnost v\u00e9st proud (jmenovit\u00fd proud); porovn\u00e1v\u00e1te schopnost p\u0159e\u017e\u00edt v\u00fdbuch. ACB je navr\u017een tak, aby zvl\u00e1dl n\u00e1sil\u00ed, kter\u00e9 by zp\u016fsobilo katastrofick\u00e9 selh\u00e1n\u00ed MCCB.<\/p>\n<h2>1. Skryt\u00e9 \u010d\u00edslo: Definov\u00e1n\u00ed zdi Icu<\/h2>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19946\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Hidden-Number-Defining-the-Icu-Wall.webp\" alt=\"The Hidden Number: Defining the Icu Wall\" width=\"800\" height=\"800\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Hidden-Number-Defining-the-Icu-Wall.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Hidden-Number-Defining-the-Icu-Wall-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Hidden-Number-Defining-the-Icu-Wall-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Hidden-Number-Defining-the-Icu-Wall-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Hidden-Number-Defining-the-Icu-Wall-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Hidden-Number-Defining-the-Icu-Wall-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Hidden-Number-Defining-the-Icu-Wall-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Nejd\u016fle\u017eit\u011bj\u0161\u00ed, ale nejv\u00edce nepochopen\u00e9 \u010d\u00edslo v rozs\u00e1hl\u00e9 distribuci energie je **Icu (jmenovit\u00e1 mezn\u00ed zkratov\u00e1 vyp\u00ednac\u00ed schopnost)**.<\/p>\n<p>Icu v\u00e1m \u0159\u00edk\u00e1 maxim\u00e1ln\u00ed zkratov\u00fd proud, kter\u00fd m\u016f\u017ee jisti\u010d bezpe\u010dn\u011b p\u0159eru\u0161it *bez zni\u010den\u00ed*. Pokud skute\u010dn\u00fd poruchov\u00fd proud p\u0159ekro\u010d\u00ed jmenovitou hodnotu Icu jisti\u010de, jisti\u010d nemus\u00ed poruchu odstranit, co\u017e vede k masivn\u00ed, nekontrolovan\u00e9 explozi zn\u00e1m\u00e9 jako elektrick\u00fd oblouk.<\/p>\n<h3>Fyzick\u00fd strop MCCB<\/h3>\n<p>Vzhledem k jejich uzav\u0159en\u00e9mu plastov\u00e9mu pouzdru dosahuj\u00ed lisovan\u00e9 jisti\u010de (MCCB) bezpe\u010dnostn\u00edho stropu:<\/p>\n<ul>\n<li><strong>Typick\u00fd limit MCCB:<\/strong> Icu obvykle dosahuje maxim\u00e1ln\u011b 65 kA a\u017e 85 kA.<\/li>\n<li><strong>Past:<\/strong> Tento strop je pevn\u011b stanoven pevnost\u00ed plastov\u00e9ho pouzdra.<\/li>\n<\/ul>\n<p>Ve vysoce v\u00fdkonn\u00fdch syst\u00e9mech \u2013 zejm\u00e9na t\u011bch, kter\u00e9 jsou nap\u00e1jeny n\u011bkolika, velk\u00fdmi nebo \u00fazce propojen\u00fdmi transform\u00e1tory \u2013 m\u016f\u017ee dostupn\u00fd poruchov\u00fd proud snadno p\u0159ekro\u010dit **100 kA**. Toto je ze\u010f Icu.<\/p>\n<h2>2. Bod zlomu: Chlazen\u00ed plastem vs. otev\u0159en\u00fdm vzduchem<\/h2>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19947\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Breaking-Point-Plastic-vs.-Open-Air-Quenching.webp\" alt=\"The Breaking Point: Plastic vs. Open Air Quenching\" width=\"800\" height=\"800\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Breaking-Point-Plastic-vs.-Open-Air-Quenching.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Breaking-Point-Plastic-vs.-Open-Air-Quenching-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Breaking-Point-Plastic-vs.-Open-Air-Quenching-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Breaking-Point-Plastic-vs.-Open-Air-Quenching-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Breaking-Point-Plastic-vs.-Open-Air-Quenching-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Breaking-Point-Plastic-vs.-Open-Air-Quenching-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Breaking-Point-Plastic-vs.-Open-Air-Quenching-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Rozd\u00edl mezi t\u011bmito dv\u011bma technologiemi spo\u010d\u00edv\u00e1 v tom, jak zvl\u00e1daj\u00ed obrovskou, n\u00e1silnou energii masivn\u00edho zkratov\u00e9ho oblouku.<\/p>\n<h3>Re\u017eim selh\u00e1n\u00ed MCCB (riziko v\u00fdbuchu)<\/h3>\n<p>MCCB odstra\u0148uje oblouk spol\u00e9h\u00e1n\u00edm se na tlak vytvo\u0159en\u00fd p\u0159eh\u0159\u00e1t\u00fdm plazmatem uvnit\u0159 jeho mal\u00fdch obloukov\u00fdch kan\u00e1l\u016f. Tento tlak mus\u00ed b\u00fdt zadr\u017een okoln\u00edm plastov\u00fdm pouzdrem. Pokud poruchov\u00fd proud p\u0159ekro\u010d\u00ed ze\u010f Icu, tlak p\u0159ekon\u00e1 pevnost plastu v tahu.<\/p>\n<blockquote><p>MCCB nejen sel\u017ee; <strong>exploduje<\/strong>. Pouzdro praskne a vyst\u0159\u00edkne roztaven\u00fd kov a ionizovan\u00fd plyn (plazma) do rozvad\u011b\u010de, co\u017e \u010dasto vede k poru\u0161e cel\u00e9ho syst\u00e9mu.<\/p><\/blockquote>\n<p>Za\u0159\u00edzen\u00ed navr\u017een\u00e9 k ochran\u011b va\u0161eho majetku se st\u00e1v\u00e1 zdrojem katastrofy.<\/p>\n<h3>\u0158e\u0161en\u00ed ACB (Pr\u016fmyslov\u00fd gigant)<\/h3>\n<p>Vzduchov\u00fd jisti\u010d (ACB) pou\u017e\u00edv\u00e1 zcela odli\u0161n\u00fd princip:<\/p>\n<ul>\n<li><strong>Otev\u0159en\u00e1 struktura:<\/strong> ACB maj\u00ed rozs\u00e1hl\u00e9, otev\u0159en\u00e9 vzduchov\u00e9 obloukov\u00e9 komory a mnohem v\u011bt\u0161\u00ed m\u011bd\u011bn\u00e9 kontakty.<\/li>\n<li><strong>\u0158\u00edzen\u00ed oblouku:<\/strong> Pou\u017e\u00edvaj\u00ed siln\u00e9 elektromagnetick\u00e9 s\u00edly a velk\u00e9 izolovan\u00e9 desky k rychl\u00e9mu nata\u017een\u00ed, ochlazen\u00ed a uha\u0161en\u00ed oblouku ve velk\u00e9m objemu vzduchu, \u010d\u00edm\u017e bezpe\u010dn\u011b odv\u00e1d\u011bj\u00ed energii.<\/li>\n<li><strong>Bezpe\u010dnostn\u00ed rezerva:<\/strong> Jmenovit\u00e9 hodnoty Icu ACB obvykle za\u010d\u00ednaj\u00ed tam, kde kon\u010d\u00ed MCCB \u2013 od 80 kA a snadno p\u0159ekra\u010duj\u00ed 100 kA nebo 120 kA.<\/li>\n<\/ul>\n<p>ACB je navr\u017een tak, aby bezpe\u010dn\u011b zvl\u00e1dl maxim\u00e1ln\u00ed energii zkratu, kterou m\u016f\u017ee syst\u00e9m fyzicky generovat, co\u017e z n\u011bj \u010din\u00ed dokonal\u00e9ho str\u00e1\u017ece bezpe\u010dnosti.<\/p>\n<h2>3. Bezpe\u010dnostn\u00ed po\u017eadavek: Kdy mus\u00edte pou\u017e\u00edt ACB<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-19948\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Safety-Requirement-When-You-Must-Use-the-ACB.webp\" alt=\"The Safety Requirement: When You Must Use the ACB\" width=\"800\" height=\"800\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Safety-Requirement-When-You-Must-Use-the-ACB.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Safety-Requirement-When-You-Must-Use-the-ACB-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Safety-Requirement-When-You-Must-Use-the-ACB-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Safety-Requirement-When-You-Must-Use-the-ACB-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Safety-Requirement-When-You-Must-Use-the-ACB-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Safety-Requirement-When-You-Must-Use-the-ACB-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Safety-Requirement-When-You-Must-Use-the-ACB-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Volba mezi t\u011bmito dv\u011bma je ot\u00e1zkou definice role v elektrick\u00e9 s\u00edti. Pokud navrhujete hlavn\u00ed vstupn\u00ed veden\u00ed, va\u0161\u00edm hlavn\u00edm z\u00e1jmem je **Bezpe\u010dnost a p\u0159e\u017eit\u00ed**.<\/p>\n<p>ACB (nebo jinou vysoce hodnocenou ochranu) mus\u00edte pou\u017e\u00edt, kdy\u017e:<\/p>\n<ul>\n<li><strong>Hlavn\u00ed jisti\u010d:<\/strong> Poruchov\u00fd proud na hlavn\u00edm vstupn\u00edm veden\u00ed je nejvy\u0161\u0161\u00ed, proto\u017ee je nejbl\u00ed\u017ee neomezen\u00e9mu zdroji energie (transform\u00e1toru rozvodn\u00e9 s\u00edt\u011b).<\/li>\n<li><strong>Veden\u00ed s vysok\u00fdm proudem:<\/strong> Veden\u00ed dimenzovan\u00e1 na 800 A a v\u00edce obecn\u011b vy\u017eaduj\u00ed pou\u017eit\u00ed ACB kv\u016fli inherentn\u00edmu vysok\u00e9mu poruchov\u00e9mu proudu a nutnosti dlouhodob\u00e9 \u00fadr\u017eby.<\/li>\n<li><strong>Kritick\u00e1 selektivita:<\/strong> ACB maj\u00ed vynikaj\u00edc\u00ed elektronick\u00e9 spou\u0161t\u011bc\u00ed jednotky nezbytn\u00e9 pro p\u0159esnou koordinaci s ka\u017ed\u00fdm pod\u0159\u00edzen\u00fdm MCCB, co\u017e zaji\u0161\u0165uje, \u017ee se spust\u00ed pouze jisti\u010d nejbli\u017e\u0161\u00ed poru\u0161e (funkce kritick\u00e1 pro minimalizaci prostoj\u016f v\u00fdroby).<\/li>\n<\/ul>\n<p>Pravdou je, \u017ee i kdy\u017e m\u016f\u017ee b\u00fdt MCCB 2500 A levn\u011bj\u0161\u00ed, ACB 2500 A je jedin\u00e9 za\u0159\u00edzen\u00ed dimenzovan\u00e9 tak, aby p\u0159e\u017eilo nejhor\u0161\u00ed sc\u00e9n\u00e1\u0159. Pokud je v s\u00e1zce bezpe\u010dnost cel\u00e9 va\u0161\u00ed p\u0159\u00edpojnice, rozvad\u011b\u010de a person\u00e1lu, je vynikaj\u00edc\u00ed vyp\u00ednac\u00ed schopnost ACB nesmlouvavou pojistkou.<\/p>\n<p>ACB nestoj\u00ed v\u00edce \u2013 jednodu\u0161e pln\u00ed nepovinnou, vy\u0161\u0161\u00ed \u00farove\u0148 bezpe\u010dnostn\u00ed povinnosti.<\/p>\n<hr \/>\n<h2>Technick\u00e9 P\u0159esnost Pozn\u00e1mka<\/h2>\n<p><strong>Normy a zdroje, na kter\u00e9 se odkazuje<\/strong><\/p>\n<ul>\n<li><strong><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/66277\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60947-2<\/a>:<\/strong> \u0158\u00edd\u00edc\u00ed norma pro MCCB i ACB, definuj\u00edc\u00ed jmenovitou hodnotu Icu a testovac\u00ed postupy.<\/li>\n<li><strong>Fyzick\u00e9 limity:<\/strong> MCCB Icu je omezena pevnost\u00ed termosetov\u00e9 plastov\u00e9 sk\u0159\u00edn\u011b a objemem zh\u00e1\u0161ec\u00ed komory; ACB Icu je \u0159\u00edzena objemem zh\u00e1\u0161en\u00ed na voln\u00e9m vzduchu a rychlost\u00ed odd\u011blen\u00ed kontakt\u016f.<\/li>\n<li><strong>Pr\u016fmyslov\u00e1 praxe:<\/strong> ACB jsou standardem pro hlavn\u00ed rozvad\u011b\u010de nad 800 A kv\u016fli vysok\u00fdm poruchov\u00fdm proud\u016fm, povinn\u00fdm bezpe\u010dnostn\u00edm rezerv\u00e1m a po\u017eadavk\u016fm na \u00fadr\u017ebu.<\/li>\n<\/ul>\n<p><strong>Prohl\u00e1\u0161en\u00ed o aktu\u00e1lnosti<\/strong><\/p>\n<p>V\u0161echny principy t\u00fdkaj\u00edc\u00ed se vyp\u00ednac\u00ed schopnosti (Icu), v\u00fdpo\u010dtu poruchov\u00e9ho proudu a fyzick\u00fdch limit\u016f technologi\u00ed jisti\u010d\u016f z\u016fst\u00e1vaj\u00ed z\u00e1kladem modern\u00ed elektroin\u017een\u00fdrsk\u00e9 praxe k listopadu 2025.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>You\u2019re reviewing the panel design budget. The specification calls for a 2500A main service entrance breaker. You find two options: Option A (MCCB): Cheap, compact, and rated for 2500A. Option B (ACB): Massive, bulky, and five times the price. The question inevitably lands on the electrical engineer&#8217;s desk: &#8220;Why are we paying so much for [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":19951,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-19943","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts\/19943","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/comments?post=19943"}],"version-history":[{"count":3,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts\/19943\/revisions"}],"predecessor-version":[{"id":19950,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts\/19943\/revisions\/19950"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media\/19951"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media?parent=19943"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/categories?post=19943"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/tags?post=19943"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}