{"id":19117,"date":"2025-08-11T13:01:56","date_gmt":"2025-08-11T05:01:56","guid":{"rendered":"https:\/\/viox.com\/?p=19117"},"modified":"2025-08-11T13:01:58","modified_gmt":"2025-08-11T05:01:58","slug":"where-to-use-sp-tp-tpn-and-4p-circuit-breakers","status":"publish","type":"post","link":"https:\/\/test.viox.com\/cs\/where-to-use-sp-tp-tpn-and-4p-circuit-breakers\/","title":{"rendered":"Kde Pou\u017e\u00edvat SP, TP, TPV a 4P Jisti\u010de"},"content":{"rendered":"<div class=\"product-intro\">\n<p>Jisti\u010de jsou z\u00e1kladn\u00ed bezpe\u010dnostn\u00ed za\u0159\u00edzen\u00ed, kter\u00e9 chr\u00e1n\u00ed elektrick\u00e9 obvody p\u0159ed p\u0159et\u00ed\u017een\u00edm a zkratem. <strong>Hlavn\u00ed rozd\u00edl mezi SP, TP, TPV, a 4P jisti\u010de spo\u010d\u00edv\u00e1 v po\u010dtu p\u00f3l\u016f a jejich aplikace<\/strong>: SP (Jeden P\u00f3l), 120V jednof\u00e1zov\u00e9 obvody, TP (Triple P\u00f3l) pro 240 V\/480 V, t\u0159i f\u00e1ze obvody bez neutr\u00e1ln\u00ed prost\u0159ed\u00ed, TPN (Triple P\u00f3l + Neutr\u00e1ln\u00ed) pro t\u0159\u00edf\u00e1zov\u00e9 obvody vy\u017eaduj\u00ed neutr\u00e1ln\u00ed prost\u0159ed\u00ed, a 4P (\u010cty\u0159i Ty\u010de) pro kompletn\u00ed t\u0159\u00edf\u00e1zov\u00e9 syst\u00e9my s neutr\u00e1ln\u00ed a uzemn\u011bn\u00ed ochrany.<\/p>\n<p>Porozum\u011bn\u00ed, kter\u00e9 jisti\u010d pou\u017e\u00edt zaji\u0161\u0165uje elektrickou bezpe\u010dnost, k\u00f3d pln\u011bn\u00ed, a optim\u00e1ln\u00ed v\u00fdkon syst\u00e9mu pro va\u0161i konkr\u00e9tn\u00ed aplikaci.<\/p>\n<h2>Jak\u00e9 Jsou Jisti\u010d P\u00f3ly a Pro\u010d Jsou d\u016fle\u017eit\u00e9?<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-18310\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/MCB-Pole-Configurations-.webp\" alt=\"MCB Pole Configurations\" width=\"900\" height=\"350\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/MCB-Pole-Configurations-.webp 900w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/MCB-Pole-Configurations--300x117.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/MCB-Pole-Configurations--768x299.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/MCB-Pole-Configurations--18x7.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/MCB-Pole-Configurations--600x233.webp 600w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/p>\n<p><strong><a href=\"https:\/\/test.viox.com\/cs\/mcb\/\">Jisti\u010d<\/a> pol\u00e1ci<\/strong> jsou jednotliv\u00e9 sp\u00ednac\u00ed mechanismy v r\u00e1mci jisti\u010d, kter\u00fd kontrolu elektrick\u00e9ho proudu. Ka\u017ed\u00fd p\u00f3l m\u016f\u017ee p\u0159eru\u0161it jeden vodi\u010d (dr\u00e1t), kdy\u017e jisti\u010d v\u00fdlety. Po\u010det p\u00f3l\u016f ur\u010duje, kter\u00e9 typy elektrick\u00fdch syst\u00e9m\u016f jisti\u010d m\u016f\u017ee bezpe\u010dn\u011b chr\u00e1nit.<\/p>\n<h3>Kl\u00ed\u010dov\u00e9 Pole Konfigurace:<\/h3>\n<ul>\n<li><strong>Jeden P\u00f3l (SP)<\/strong>: Ovl\u00e1d\u00e1 jeden hot dirigent<\/li>\n<li><strong>Trojit\u00fd Sloup (TP)<\/strong>: Ovl\u00e1d\u00e1 t\u0159i hork\u00e9 vodi\u010de sou\u010dasn\u011b<\/li>\n<li><strong>Trojn\u00e1sobn\u00fd P\u00f3l + Neutr\u00e1ln\u00ed (TPN)<\/strong>: Ovl\u00e1d\u00e1 t\u0159i hork\u00e9 vodi\u010de plus neutr\u00e1ln\u00ed<\/li>\n<li><strong>\u010cty\u0159i P\u00f3l (4P)<\/strong>: Ovl\u00e1d\u00e1 t\u0159i hork\u00e9 vodi\u010de plus neutr\u00e1ln\u00ed, se zv\u00fd\u0161enou ochranou<\/li>\n<\/ul>\n<h2>Kompletn\u00ed Jisti\u010d Typ Porovn\u00e1n\u00ed<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Jisti\u010d Typ<\/th>\n<th>Pol\u00e1ci<\/th>\n<th>Nap\u011bt\u00ed<\/th>\n<th>Prim\u00e1rn\u00ed Aplikace<\/th>\n<th>Neutr\u00e1ln\u00ed Ochrana<\/th>\n<th>N\u00e1klady Rozsah<\/th>\n<\/tr>\n<tr>\n<td><strong>SP (Single Pole)<\/strong><\/td>\n<td>1<\/td>\n<td>120V<\/td>\n<td>Bytov\u00e9 osv\u011btlen\u00ed, z\u00e1suvky, mal\u00e9 spot\u0159ebi\u010de<\/td>\n<td>Ne<\/td>\n<td>$5-$25<\/td>\n<\/tr>\n<tr>\n<td><strong>TP (Trojit\u00fd Sloup)<\/strong><\/td>\n<td>3<\/td>\n<td>240-480V<\/td>\n<td>Motory, topn\u00e1 t\u011blesa, t\u0159\u00edf\u00e1zov\u00e9 za\u0159\u00edzen\u00ed<\/td>\n<td>Ne<\/td>\n<td>$75-$300<\/td>\n<\/tr>\n<tr>\n<td><strong>TPN (Triple P\u00f3l + Neutr\u00e1ln\u00ed)<\/strong><\/td>\n<td>3+N<\/td>\n<td>240-480V<\/td>\n<td>T\u0159i-f\u00e1ze s neutr\u00e1ln\u00ed zat\u00ed\u017een\u00ed, sv\u011bteln\u00e9 panely<\/td>\n<td>Ano<\/td>\n<td>$150-$500<\/td>\n<\/tr>\n<tr>\n<td><strong>4P (\u010cty\u0159i Pole)<\/strong><\/td>\n<td>4<\/td>\n<td>240V-600V<\/td>\n<td>Kompletn\u00ed ochrana syst\u00e9mu, kritick\u00e1 za\u0159\u00edzen\u00ed<\/td>\n<td>Ano + Enhanced<\/td>\n<td>$200-$800<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Kdy Pou\u017e\u00edt jednop\u00f3lov\u00fd (SP) Jisti\u010de<\/h2>\n<div id='gallery-1' class='gallery galleryid-19117 gallery-columns-1 gallery-size-full'><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/test.viox.com\/cs\/?attachment_id=5574'><img decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM6-63-1-4P-6kA-230_400V-6-63A-MCB01.webp\" class=\"attachment-full size-full\" alt=\"\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM6-63-1-4P-6kA-230_400V-6-63A-MCB01.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM6-63-1-4P-6kA-230_400V-6-63A-MCB01-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM6-63-1-4P-6kA-230_400V-6-63A-MCB01-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM6-63-1-4P-6kA-230_400V-6-63A-MCB01-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM6-63-1-4P-6kA-230_400V-6-63A-MCB01-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM6-63-1-4P-6kA-230_400V-6-63A-MCB01-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a>\n\t\t\t<\/div><\/figure>\n\t\t<\/div>\n\n<p><strong>Jeden p\u00f3l jisti\u010de chr\u00e1nit 120V jednof\u00e1zov\u00e9 obvody<\/strong> a jsou nej\u010dast\u011bj\u0161\u00edm typem v obytn\u00fdch elektrick\u00fdch syst\u00e9m\u016f.<\/p>\n<h3>Prim\u00e1rn\u00ed Aplikac\u00ed pro SP Jisti\u010de:<\/h3>\n<ul>\n<li><strong>Osv\u011btlen\u00ed obytn\u00fdch obvod\u016f<\/strong> (lo\u017enice, koupelny, kuchyn\u011b)<\/li>\n<li><strong>Standardn\u00ed dom\u00e1c\u00ed z\u00e1suvky<\/strong> (15A a 20A n\u00e1doby)<\/li>\n<li><strong>Mal\u00e9 spot\u0159ebi\u010de<\/strong> (drti\u010de odpadk\u016f, my\u010dky n\u00e1dob\u00ed)<\/li>\n<li><strong>Individu\u00e1ln\u00ed ochrana za\u0159\u00edzen\u00ed<\/strong> v 120V syst\u00e9my<\/li>\n<li><strong>V\u011btven\u00e9 obvody<\/strong> v obytn\u00e9 a lehk\u00fdch u\u017eitkov\u00fdch budov<\/li>\n<\/ul>\n<h3>SP Breaker Specifikace:<\/h3>\n<ul>\n<li><strong>Nap\u011bt\u00ed<\/strong>: 120V AC<\/li>\n<li><strong>Aktu\u00e1ln\u00ed Hodnocen\u00ed<\/strong>: 15A, 20A, 30A (nej\u010dast\u011bj\u0161\u00ed)<\/li>\n<li><strong>Dr\u00e1t P\u0159ipojen\u00ed<\/strong>: Jeden hork\u00fd dr\u00e1t, neutr\u00e1ln\u00ed na panelu autobusu<\/li>\n<li><strong>Fyzick\u00e1 Velikost<\/strong>: 1&#034; \u0161irok\u00e1 (jeden prostor v panelu)<\/li>\n<\/ul>\n<blockquote><p><strong>\u26a0\ufe0f Bezpe\u010dnostn\u00ed Upozorn\u011bn\u00ed<\/strong>: Nikdy nepou\u017e\u00edvejte jeden p\u00f3l jisti\u010de na 240V obvody. To vytv\u00e1\u0159\u00ed nebezpe\u010dnou situaci, kde jeden vodi\u010d z\u016fst\u00e1v\u00e1 pod nap\u011bt\u00edm, kdy\u017e jisti\u010d v\u00fdlety.<\/p><\/blockquote>\n<h2>P\u0159i Pou\u017eit\u00ed Triple P\u00f3lu (TP) Jisti\u010de<\/h2>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-5564\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM65-63-1-4P-63A-6kA-Low-Voltage-MCB-Miniature-Circuit-Breaker.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM65-63-1-4P-63A-6kA-Low-Voltage-MCB-Miniature-Circuit-Breaker.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM65-63-1-4P-63A-6kA-Low-Voltage-MCB-Miniature-Circuit-Breaker-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM65-63-1-4P-63A-6kA-Low-Voltage-MCB-Miniature-Circuit-Breaker-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM65-63-1-4P-63A-6kA-Low-Voltage-MCB-Miniature-Circuit-Breaker-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM65-63-1-4P-63A-6kA-Low-Voltage-MCB-Miniature-Circuit-Breaker-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM65-63-1-4P-63A-6kA-Low-Voltage-MCB-Miniature-Circuit-Breaker-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p><strong>Trojn\u00e1sobn\u00fd p\u00f3l jisti\u010de ochran\u011b t\u0159\u00edf\u00e1zov\u00fdch elektrick\u00fdch syst\u00e9mech bez ochrany neutr\u00e1ln\u00ed<\/strong>, co\u017e je ide\u00e1ln\u00ed pro zat\u00ed\u017een\u00ed motoru a topn\u00e9ho za\u0159\u00edzen\u00ed.<\/p>\n<h3>Prim\u00e1rn\u00ed Aplikace pro TP Jisti\u010de:<\/h3>\n<ul>\n<li><strong>T\u0159\u00edf\u00e1zov\u00e9 motory<\/strong> (Syst\u00e9my HVAC, pr\u016fmyslov\u00e1 za\u0159\u00edzen\u00ed)<\/li>\n<li><strong>Elektrick\u00e9 oh\u0159\u00edva\u010de<\/strong> a topen\u00ed prvky<\/li>\n<li><strong>T\u0159\u00edf\u00e1zov\u00fd sva\u0159ovac\u00ed za\u0159\u00edzen\u00ed<\/strong><\/li>\n<li><strong>Pr\u016fmyslov\u00e9 stroje<\/strong> bez neutr\u00e1ln\u00ed po\u017eadavky<\/li>\n<li><strong>\u010cerpadla motory<\/strong> a kompresorov\u00fdch syst\u00e9m\u016f<\/li>\n<\/ul>\n<h3>TP Breaker Specifikace:<\/h3>\n<ul>\n<li><strong>Nap\u011bt\u00ed<\/strong>240V, 480V, 600V<\/li>\n<li><strong>Aktu\u00e1ln\u00ed Hodnocen\u00ed<\/strong>: 15A a\u017e 800A (li\u0161\u00ed se podle v\u00fdrobce)<\/li>\n<li><strong>Dr\u00e1t P\u0159ipojen\u00ed<\/strong>: T\u0159i hork\u00e9 vodi\u010de, ne neutr\u00e1ln\u00ed<\/li>\n<li><strong>Fyzick\u00e1 Velikost<\/strong>: 3&#034; \u0161irok\u00fd (t\u0159i pol\u00ed\u010dka v panelu)<\/li>\n<\/ul>\n<h3>TP vs SP Kl\u00ed\u010dov\u00e9 Rozd\u00edly:<\/h3>\n<ul>\n<li><strong>Sou\u010dasn\u00e9 Vypnut\u00ed<\/strong>: V\u0161echny t\u0159i p\u00f3ly v\u00fdlet pro vyv\u00e1\u017eenou ochranu<\/li>\n<li><strong>Vy\u0161\u0161\u00ed Nap\u011bt\u00ed Schopnosti<\/strong>: Rukojeti 240-480 V t\u0159\u00edf\u00e1zov\u00fd syst\u00e9my<\/li>\n<li><strong>Ochrana Motoru<\/strong>: Speci\u00e1ln\u011b navr\u017een pro t\u0159i-f\u00e1ze zat\u00ed\u017een\u00ed motoru<\/li>\n<\/ul>\n<h2>Kdy Pou\u017e\u00edt TPN (Triple P\u00f3l + Neutr\u00e1ln\u00ed) Jisti\u010de<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-13920\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-4P-Residual-Current-Operated-Circuit-Breaker-RCCB.webp\" alt=\"VML01 4P Residual Current Operated Circuit Breaker (RCCB)\" width=\"800\" height=\"800\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-4P-Residual-Current-Operated-Circuit-Breaker-RCCB.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-4P-Residual-Current-Operated-Circuit-Breaker-RCCB-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-4P-Residual-Current-Operated-Circuit-Breaker-RCCB-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-4P-Residual-Current-Operated-Circuit-Breaker-RCCB-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-4P-Residual-Current-Operated-Circuit-Breaker-RCCB-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-4P-Residual-Current-Operated-Circuit-Breaker-RCCB-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-4P-Residual-Current-Operated-Circuit-Breaker-RCCB-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p><strong>TPN jisti\u010de poskytuj\u00ed ochranu pro t\u0159\u00edf\u00e1zov\u00e9 syst\u00e9my, kter\u00e9 vy\u017eaduj\u00ed neutr\u00e1ln\u00ed monitorov\u00e1n\u00ed a ochrana<\/strong>z\u00e1sadn\u00ed v\u00fdznam pro osv\u011btlen\u00ed a sm\u00ed\u0161en\u00e9 aplikace zat\u00ed\u017een\u00ed.<\/p>\n<h3>Prim\u00e1rn\u00ed Aplikace pro TPN Jisti\u010de:<\/h3>\n<ul>\n<li><strong>T\u0159i-f\u00e1ze sv\u011bteln\u00e9 panely<\/strong> s neutr\u00e1ln\u00ed zat\u00ed\u017een\u00ed<\/li>\n<li><strong>Sm\u00ed\u0161en\u00e9 komer\u010dn\u00ed zat\u00ed\u017een\u00ed<\/strong> (sv\u011btel, z\u00e1suvek, drobn\u00e9 vybaven\u00ed)<\/li>\n<li><strong>Distribu\u010dn\u00ed panely<\/strong> slou\u017e\u00ed jak line-k-line a line-to-neutr\u00e1ln\u00ed zat\u00ed\u017een\u00ed<\/li>\n<li><strong>Po\u010d\u00edta\u010de a elektronick\u00e1 za\u0159\u00edzen\u00ed<\/strong> vy\u017eaduj\u00ed neutr\u00e1ln\u00ed ochrana<\/li>\n<li><strong>Komer\u010dn\u00ed vybaven\u00ed kuchyn\u011b<\/strong> se sm\u00ed\u0161en\u00fdmi po\u017eadavky na nap\u011bt\u00ed<\/li>\n<\/ul>\n<h3>TPN Breaker Specifikace:<\/h3>\n<ul>\n<li><strong>Nap\u011bt\u00ed<\/strong>: 120\/208V, 277\/480V syst\u00e9my<\/li>\n<li><strong>Aktu\u00e1ln\u00ed Hodnocen\u00ed<\/strong>: 15A a\u017e 400A<\/li>\n<li><strong>Dr\u00e1t P\u0159ipojen\u00ed<\/strong>: T\u0159i hork\u00e9 vodi\u010de plus neutr\u00e1ln\u00ed<\/li>\n<li><strong>Neutr\u00e1ln\u00ed Ochrana<\/strong>: Monitory neutr\u00e1ln\u00ed pro p\u0159et\u00ed\u017een\u00ed a poruchov\u00fdch stav\u016f<\/li>\n<\/ul>\n<h3>TPN V\u00fdhody:<\/h3>\n<ul>\n<li><strong>Kompletn\u00ed Ochrana Obvodu<\/strong>: Chr\u00e1n\u00ed ob\u011b f\u00e1ze a neutr\u00e1ln\u00ed vodi\u010de<\/li>\n<li><strong>Nevyv\u00e1\u017een\u00e9 Zat\u00ed\u017een\u00ed Manipulaci<\/strong>: \u0158\u00edd\u00ed syst\u00e9my s r\u016fznou z\u00e1t\u011b\u017e\u00ed na f\u00e1zi<\/li>\n<li><strong>K\u00f3d Souladu<\/strong>: Spl\u0148uje po\u017eadavky pro neutr\u00e1ln\u00ed prost\u0159ed\u00ed v konkr\u00e9tn\u00edch aplikac\u00ed<\/li>\n<\/ul>\n<blockquote><p><strong>\ud83d\udca1 Expert Tip<\/strong>: TPN jisti\u010de jsou vy\u017eadov\u00e1ny NEC (National Electrical Code) p\u0159i serv\u00edrov\u00e1n\u00ed line-to-neutr\u00e1ln\u00ed zat\u00ed\u017een\u00ed v t\u0159\u00edf\u00e1zov\u00fdch syst\u00e9mech se sd\u00edlenou neutr\u00e1ln\u00ed.<\/p><\/blockquote>\n<h2>Kdy Pou\u017e\u00edt 4P (\u010cty\u0159i Pole) Jisti\u010de<\/h2>\n<p><strong>\u010cty\u0159i p\u00f3l jisti\u010de poskytuj\u00ed nejvy\u0161\u0161\u00ed \u00farove\u0148 ochrany<\/strong> pro t\u0159\u00edf\u00e1zov\u00e9 syst\u00e9my, v\u010detn\u011b uzemn\u011bn\u00ed a lep\u0161\u00ed neutr\u00e1ln\u00ed prost\u0159ed\u00ed.<\/p>\n<h3>Prim\u00e1rn\u00ed Aplikace pro 4P Jisti\u010de:<\/h3>\n<ul>\n<li><strong>Hlavn\u00ed elektrick\u00e9 panely<\/strong> v komer\u010dn\u00edch budov\u00e1ch<\/li>\n<li><strong>Kritick\u00e9 za\u0159\u00edzen\u00ed na ochranu<\/strong> (server\u016f, zdravotnick\u00fdch za\u0159\u00edzen\u00ed)<\/li>\n<li><strong>Ochrana proti zemn\u00edmu<\/strong> po\u017eadavky<\/li>\n<li><strong>Baz\u00e9n a l\u00e1ze\u0148sk\u00e9 za\u0159\u00edzen\u00ed<\/strong><\/li>\n<li><strong>Venkovn\u00ed elektrick\u00e1 za\u0159\u00edzen\u00ed<\/strong> vy\u017eaduje GFCI ochranu<\/li>\n<li><strong>Pr\u016fmyslov\u00e9 ovl\u00e1dac\u00ed panely<\/strong> s po\u017eadavky na bezpe\u010dnost<\/li>\n<\/ul>\n<h3>4P Jisti\u010d Specifikace:<\/h3>\n<ul>\n<li><strong>Nap\u011bt\u00ed<\/strong>: 240V do 600V<\/li>\n<li><strong>Aktu\u00e1ln\u00ed Hodnocen\u00ed<\/strong>: 20A a\u017e 1200A<\/li>\n<li><strong>Dr\u00e1t P\u0159ipojen\u00ed<\/strong>: T\u0159i hork\u00e9 vodi\u010de, neutr\u00e1ln\u00ed a pozemn\u00ed za\u0159\u00edzen\u00ed<\/li>\n<li><strong>Funkce Ochrany<\/strong>: Nadproud, zemn\u00ed spojen\u00ed, oblouk chyba (k dispozici)<\/li>\n<\/ul>\n<h3>Pokro\u010dil\u00e9 Funkce Ochrany:<\/h3>\n<ul>\n<li><strong>Ground Fault Circuit P\u0159eru\u0161en\u00ed (GFCI)<\/strong>: Chr\u00e1n\u00ed proti zemn\u00edmu spojen\u00ed<\/li>\n<li><strong>Oblouk Chyba Obvodu P\u0159eru\u0161en\u00ed (AFCI)<\/strong>: Detekuje nebezpe\u010dn\u00e9 jisk\u0159en\u00ed podm\u00ednky<\/li>\n<li><strong>Elektronick\u00e9 V\u00fdlet Jednotek<\/strong>: Programovateln\u00e9 nastaven\u00ed ochrany<\/li>\n<li><strong>Komunika\u010dn\u00ed Schopnosti<\/strong>: Integrace se syst\u00e9my \u0159\u00edzen\u00ed budov<\/li>\n<\/ul>\n<h2>Jisti\u010d Krit\u00e9ria V\u00fdb\u011bru<\/h2>\n<h3>Krok-za-Krokem Procesu V\u00fdb\u011bru:<\/h3>\n<ol>\n<li><strong>Ur\u010dit Syst\u00e9m Nap\u011bt\u00ed<\/strong>\n<ul>\n<li>Jednof\u00e1zov\u00e9 120V \u2192 SP breaker<\/li>\n<li>T\u0159i-f\u00e1ze 240 V\/480 V \u2192 TP, TPV, nebo 4P<\/li>\n<\/ul>\n<\/li>\n<li><strong>Identifikaci Po\u017eadavk\u016f Na Zat\u00ed\u017een\u00ed<\/strong>\n<ul>\n<li>Motor bez zat\u00ed\u017een\u00ed neutr\u00e1ln\u00ed \u2192 TP<\/li>\n<li>Sm\u00ed\u0161en\u00e9 zat\u00ed\u017een\u00ed s neutr\u00e1ln\u00ed \u2192 TPN<\/li>\n<li>Kritick\u00e9 syst\u00e9my \u2192 4P<\/li>\n<\/ul>\n<\/li>\n<li><strong>Zkontrolujte K\u00f3d Po\u017eadavky<\/strong>\n<ul>\n<li>Ov\u011b\u0159it NEC shody pro va\u0161i aplikaci<\/li>\n<li>Potvrzen\u00ed m\u00edstn\u00ed elektrick\u00e9 k\u00f3d po\u017eadavky<\/li>\n<li>V \u00favahu zvl\u00e1\u0161tn\u00ed pot\u0159eby ochrany (GFCI, AFCI)<\/li>\n<\/ul>\n<\/li>\n<li><strong>V\u00fdpo\u010det Aktu\u00e1ln\u00ed Hodnocen\u00ed<\/strong>\n<ul>\n<li>Zat\u011b\u017eovac\u00ed proud \u00d7 1.25 = minim\u00e1ln\u00ed jisti\u010d hodnocen\u00ed<\/li>\n<li>Zva\u017ete rozb\u011bhov\u00e9ho proudu pro motory<\/li>\n<li>\u00da\u010det pro budouc\u00ed roz\u0161\u00ed\u0159en\u00ed pot\u0159ebuje<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h3>Rychl\u00fd V\u00fdb\u011br Referen\u010dn\u00ed Tabulka:<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Typ Aplikace<\/th>\n<th>Doporu\u010den\u00fd Jisti\u010d<\/th>\n<th>Kl\u00ed\u010dov\u00e9 \u00davahy<\/th>\n<\/tr>\n<tr>\n<td>Bytov\u00e9 osv\u011btlen\u00ed\/prodejny<\/td>\n<td>SP<\/td>\n<td>15A nebo 20A hodnocen\u00ed<\/td>\n<\/tr>\n<tr>\n<td>T\u0159\u00edf\u00e1zov\u00fd motor<\/td>\n<td>TP<\/td>\n<td>Motorov\u00fd rozb\u011bhov\u00fd proud<\/td>\n<\/tr>\n<tr>\n<td>Komer\u010dn\u00ed osv\u011btlen\u00ed panelu<\/td>\n<td>TPN<\/td>\n<td>Neutr\u00e1ln\u00ed vyv\u00e1\u017een\u00ed zat\u00ed\u017een\u00ed<\/td>\n<\/tr>\n<tr>\n<td>Hlavn\u00ed elektrick\u00e9 slu\u017eby<\/td>\n<td>4P<\/td>\n<td>Ochrana proti zemn\u00edmu<\/td>\n<\/tr>\n<tr>\n<td>Baz\u00e9n\/spa za\u0159\u00edzen\u00ed<\/td>\n<td>4P s GFCI<\/td>\n<td>Vody bezpe\u010dnostn\u00ed po\u017eadavky<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>K\u00f3d Shody a Po\u017eadavky na Bezpe\u010dnost<\/h2>\n<h3>National Electrical Code (NEC) Po\u017eadavky:<\/h3>\n<p><strong>\u010cl\u00e1nek 240 \u2013 Nadproudov\u00e1 Ochrana:<\/strong><\/p>\n<ul>\n<li>Jisti\u010de mus\u00ed b\u00fdt dimenzov\u00e1n pro k dispozici poruchov\u00fd proud<\/li>\n<li>Spr\u00e1vn\u00e9 vodi\u010de ochrana na z\u00e1klad\u011b dr\u00e1tu zat\u00ed\u017eitelnost<\/li>\n<li>Pot\u0159ebn\u00e9 prost\u0159edky pro odpojen\u00ed za\u0159\u00edzen\u00ed<\/li>\n<\/ul>\n<p><strong>\u010cl\u00e1nek 210 \u2013 Odbo\u010dky:<\/strong><\/p>\n<ul>\n<li>SP jisti\u010de pro 120V odbo\u010dky<\/li>\n<li>Multi-p\u00f3lov\u00e9 jisti\u010de pro multi-vodi\u010d odbo\u010dky<\/li>\n<li>GFCI po\u017eadavky na ochranu pro ur\u010dit\u00e9 lokality<\/li>\n<\/ul>\n<p><strong>\u010cl\u00e1nek 430 \u2013 Motory:<\/strong><\/p>\n<ul>\n<li>Obvod motoru po\u017eadavky na ochranu<\/li>\n<li>Ochrana proti p\u0159et\u00ed\u017een\u00ed odd\u011blen\u00e9 od zkratu ochrana<\/li>\n<li>Spr\u00e1vn\u00fd motor controller koordinace<\/li>\n<\/ul>\n<blockquote><p><strong>\u26a0\ufe0f Kritick\u00e9 Bezpe\u010dnostn\u00ed Pozn\u00e1mka<\/strong>: V\u017edy se pora\u010fte s kvalifikovan\u00fdm elektrik\u00e1\u0159em za jisti\u010d v\u00fdb\u011br a instalace. Nespr\u00e1vn\u00fd v\u00fdb\u011br m\u016f\u017ee m\u00edt za n\u00e1sledek nebezpe\u010d\u00ed po\u017e\u00e1ru, po\u0161kozen\u00ed za\u0159\u00edzen\u00ed, a poru\u0161en\u00ed kodexu.<\/p><\/blockquote>\n<h2>Instalace a \u00dadr\u017eba Osv\u011bd\u010den\u00fdch Postup\u016f<\/h2>\n<h3>Profesion\u00e1ln\u00ed Instalace Po\u017eadavky:<\/h3>\n<ul>\n<li><strong>Licencovan\u00e9 elektrik\u00e1\u0159<\/strong> povinn\u00e9 pro v\u0161echny jisti\u010d za\u0159\u00edzen\u00ed<\/li>\n<li><strong>Spr\u00e1vn\u00fd utahovac\u00ed moment<\/strong> pro p\u0159ipojen\u00ed vodi\u010d\u016f<\/li>\n<li><strong>Arc flash analysis<\/strong> pro komer\u010dn\u00ed a pr\u016fmyslov\u00e9 aplikace<\/li>\n<li><strong>Syst\u00e9m koordinace studie<\/strong> pro komplexn\u00ed elektrick\u00e9 syst\u00e9my<\/li>\n<\/ul>\n<h3>Pokyny Pro \u00dadr\u017ebu:<\/h3>\n<ul>\n<li><strong>Ro\u010dn\u00ed prohl\u00eddky<\/strong> jisti\u010de provozu a p\u0159ipojen\u00ed<\/li>\n<li><strong>Termovize<\/strong> pro detekci hork\u00fdch m\u00edst a voln\u00e9 p\u0159ipojen\u00ed<\/li>\n<li><strong>Cvi\u010den\u00ed jisti\u010de<\/strong> m\u011bs\u00ed\u010dn\u011b u kritick\u00fdch aplikac\u00ed<\/li>\n<li><strong>Vym\u011b\u0148te jisti\u010de<\/strong> vykazuje zn\u00e1mky jisk\u0159en\u00ed nebo po\u0161kozen\u00ed<\/li>\n<\/ul>\n<h2>Spole\u010dn\u00fd Jisti\u010d V\u00fdb\u011br Chyb<\/h2>\n<h3>Vyhn\u011bte Se Tyto Kritick\u00e9 Chyby:<\/h3>\n<ol>\n<li><strong>\u0160patn\u011b P\u00f3l Konfigurace<\/strong>\n<ul>\n<li>Pomoc\u00ed SP jisti\u010de na 240V obvody<\/li>\n<li>Vynech\u00e1n\u00ed neutr\u00e1ln\u00ed ochranu p\u0159i po\u017eadovan\u00e9<\/li>\n<\/ul>\n<\/li>\n<li><strong>Nespr\u00e1vn\u00e9 Aktu\u00e1ln\u00ed Hodnocen\u00ed<\/strong>\n<ul>\n<li>Undersizing pro motor startovac\u00ed proud<\/li>\n<li>N\u00e1padn\u00e9 nad dirigent kapacity<\/li>\n<\/ul>\n<\/li>\n<li><strong>Poru\u0161en\u00ed Kodexu<\/strong>\n<ul>\n<li>Chyb\u00ed GFCI ochranu v po\u017eadovan\u00fdch m\u00edstech<\/li>\n<li>Nespr\u00e1vn\u00e9 uzemn\u011bn\u00ed a lepen\u00ed<\/li>\n<\/ul>\n<\/li>\n<li><strong>Probl\u00e9my S Kompatibilitou<\/strong>\n<ul>\n<li>M\u00edch\u00e1n\u00ed breaker zna\u010dek v panelech<\/li>\n<li>Pou\u017e\u00edv\u00e1n\u00ed zastaral\u00fdch breaker typy<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2>\u0158e\u0161en\u00ed Probl\u00e9m\u016f Jisti\u010d Probl\u00e9m\u016f<\/h2>\n<h3>B\u011b\u017en\u00e9 Probl\u00e9my a \u0158e\u0161en\u00ed:<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Probl\u00e9m<\/th>\n<th>Mo\u017en\u00e9 P\u0159\u00ed\u010diny<\/th>\n<th>\u0158e\u0161en\u00ed<\/th>\n<\/tr>\n<tr>\n<td>\u010cast\u00e9 vyp\u00edn\u00e1n\u00ed<\/td>\n<td>P\u0159et\u00ed\u017een\u00fd obvod, vadn\u00e9 za\u0159\u00edzen\u00ed<\/td>\n<td>Zkontrolujte zat\u00ed\u017een\u00ed v\u00fdpo\u010dty, zku\u0161ebn\u00ed za\u0159\u00edzen\u00ed<\/td>\n<\/tr>\n<tr>\n<td>Nebude resetovat<\/td>\n<td>Vnit\u0159n\u00ed po\u0161kozen\u00ed, pokra\u010doval chyba<\/td>\n<td>Vym\u011b\u0148te jisti\u010d, vy\u0161et\u0159ovat obvodu<\/td>\n<\/tr>\n<tr>\n<td>Topen\u00ed\/ho\u0159\u00edc\u00ed z\u00e1pach<\/td>\n<td>Voln\u00e9 p\u0159ipojen\u00ed, p\u0159et\u00ed\u017een\u00ed<\/td>\n<td>Okam\u017eit\u00e9 vypnut\u00ed, profesion\u00e1ln\u00ed inspekce<\/td>\n<\/tr>\n<tr>\n<td>P\u0159eru\u0161ovan\u00fd provoz<\/td>\n<td>Opot\u0159eben\u00e9 kontakty, kalibrace drift<\/td>\n<td>Vym\u011b\u0148te jisti\u010d, zkontrolujte nastaven\u00ed<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u010casto Kladen\u00e9 Ot\u00e1zky<\/h2>\n<h3>Mohu nahradit jednop\u00f3lov\u00fd jisti\u010d s dvoup\u00f3lov\u00e9 jisti\u010de?<\/h3>\n<p>Ne, nem\u016f\u017eete nahradit jednop\u00f3lov\u00fd jisti\u010d s man\u017eelskou p\u00f3l jisti\u010d bez p\u0159epojov\u00e1n\u00ed okruhu. Jeden p\u00f3l jisti\u010de chr\u00e1nit 120V obvody, zat\u00edmco dvoup\u00f3lov\u00e9 jisti\u010de jsou ur\u010deny pro 240V obvody s r\u016fzn\u00fdmi zapojen\u00ed konfigurac\u00ed.<\/p>\n<h3>Jak\u00fd je rozd\u00edl mezi TPN a 4P jisti\u010de?<\/h3>\n<p>TPN (Triple P\u00f3l + Neutr\u00e1ln\u00ed) jisti\u010de poskytuj\u00ed z\u00e1kladn\u00ed neutr\u00e1ln\u00ed ochranu, zat\u00edmco 4P (\u010cty\u0159i Pole) jisti\u010de nab\u00edzej\u00ed zv\u00fd\u0161enou ochranu, v\u010detn\u011b ground fault detekce a dal\u0161\u00ed bezpe\u010dnostn\u00ed prvky. 4P jisti\u010de jsou nutn\u00e9 pro kritick\u00e9 aplikace a specifick\u00fdch po\u017eadavk\u016f.<\/p>\n<h3>Jak m\u00e1m v\u011bd\u011bt, co proud jisti\u010d budu pot\u0159ebovat?<\/h3>\n<p>V\u00fdpo\u010det celkov\u00e9 zat\u00ed\u017een\u00ed proud a vyn\u00e1sobit 1.25 (125%) pro nep\u0159etr\u017eit\u00e9 zat\u00ed\u017een\u00ed. Jisti\u010d proud nesm\u00ed p\u0159ekro\u010dit dirigent proudovou zat\u00ed\u017eitelnost. Pro motorov\u00e9 z\u00e1t\u011b\u017ee, zva\u017ete spu\u0161t\u011bn\u00ed aktu\u00e1ln\u00ed po\u017eadavky a konzultovat s NEC, \u010cl\u00e1nek 430.<\/p>\n<h3>Mohu m\u00edchat r\u016fzn\u00e9 zna\u010dky jisti\u010de ve stejn\u00e9m panelu?<\/h3>\n<p>Ne, nikdy byste nem\u011bli m\u00edchat jisti\u010d zna\u010dky v elektrick\u00e9m panelu. Ka\u017ed\u00fd panel je navr\u017een a testov\u00e1n s konkr\u00e9tn\u00ed jisti\u010d typy. Pou\u017eit\u00ed nekompatibiln\u00ed jisti\u010de dutin z\u00e1ruky a vytv\u00e1\u0159\u00ed bezpe\u010dnostn\u00ed rizika.<\/p>\n<h3>Kdy\u017e je neutr\u00e1ln\u00ed ochrany, je\u017e jsou vy\u017eadov\u00e1ny v t\u0159\u00edf\u00e1zov\u00e9 syst\u00e9my?<\/h3>\n<p>Neutr\u00e1ln\u00ed ochrana je nutn\u00e1 p\u0159i serv\u00edrov\u00e1n\u00ed line-to-neutr\u00e1ln\u00ed zat\u00ed\u017een\u00ed na t\u0159\u00edf\u00e1zov\u00fdch syst\u00e9mech, zejm\u00e9na v komer\u010dn\u00edch osv\u011btlovac\u00edch aplikac\u00ed a sm\u00ed\u0161en\u00e9 zat\u00ed\u017een\u00ed panely. NEC \u010cl\u00e1nek 210.4(A) specifikuje tyto po\u017eadavky.<\/p>\n<h3>Jak\u00e9 jsou zn\u00e1mky toho, \u017ee jisti\u010d pot\u0159ebuje v\u00fdm\u011bnu?<\/h3>\n<p>Vym\u011b\u0148te jisti\u010de zobrazeno: \u010dast\u00e9 obt\u011b\u017eov\u00e1n\u00ed vypnut\u00ed, selh\u00e1n\u00ed obnovit, p\u00e1len\u00ed von\u00ed, viditeln\u00e9 po\u0161kozen\u00ed, uvoln\u011bn\u00e9 nebo zkorodovan\u00e9 spoje, nebo v\u011bk nad r\u00e1mec doporu\u010den\u00ed v\u00fdrobce (obvykle 20-30 let).<\/p>\n<h3>Pot\u0159ebuji povolen\u00ed nahradit jisti\u010de?<\/h3>\n<p>V\u011bt\u0161ina jurisdikc\u00ed vy\u017eaduje povolen\u00ed pro jisti\u010d n\u00e1hradn\u00ed, a to zejm\u00e9na pro panel \u00faprav nebo vylep\u0161en\u00ed. Pora\u010fte se se sv\u00fdm m\u00edstn\u00ed stavebn\u00ed odd\u011blen\u00ed, a najmout elektrik\u00e1\u0159e pro spr\u00e1vnou instalaci a kontrolu.<\/p>\n<h3>Jak \u010dasto by m\u011bl jisti\u010de b\u00fdt testov\u00e1ny?<\/h3>\n<p>Test jisti\u010de m\u011bs\u00ed\u010dn\u00ed provozn\u00ed tla\u010d\u00edtko test (pokud je ve v\u00fdbav\u011b), nebo ru\u010dn\u011b v\u00fdkonu na rukojeti. Komer\u010dn\u00ed a pr\u016fmyslov\u00e9 aplikace mohou vy\u017eadovat \u010dast\u011bj\u0161\u00ed zkou\u0161ky zalo\u017een\u00fdch na kriti\u010dnosti a m\u00edstn\u00edch k\u00f3d\u016f.<\/p>\n<h2>Odborn\u00e1 Doporu\u010den\u00ed a Dal\u0161\u00ed Kroky<\/h2>\n<h3>Profesion\u00e1ln\u00ed Krit\u00e9ria V\u00fdb\u011bru:<\/h3>\n<ul>\n<li><strong>Pora\u010fte elektrotechnik\u016f<\/strong> pro komplexn\u00ed t\u0159\u00edf\u00e1zov\u00e9 syst\u00e9my<\/li>\n<li><strong>Ov\u011b\u0159te, v\u00fdrobce kompatibilitu<\/strong> se st\u00e1vaj\u00edc\u00edmi panely<\/li>\n<li><strong>Zv\u00e1\u017eit budouc\u00ed roz\u0161\u00ed\u0159en\u00ed<\/strong> p\u0159i dimenzov\u00e1n\u00ed elektrick\u00fdch syst\u00e9m\u016f<\/li>\n<li><strong>Prov\u00e1d\u011bn\u00ed preventivn\u00ed \u00fadr\u017eby<\/strong> programy pro kritick\u00e9 aplikace<\/li>\n<\/ul>\n<h3>Kdy Volat Profesion\u00e1ln\u00ed:<\/h3>\n<ul>\n<li>Jak\u00e9koliv nejistoty ohledn\u011b jisti\u010d v\u00fdb\u011br<\/li>\n<li>Panel \u00fapravy nebo vylep\u0161en\u00ed<\/li>\n<li>T\u0159\u00edf\u00e1zov\u00fd syst\u00e9m za\u0159\u00edzen\u00ed<\/li>\n<li>K\u00f3d souladu ot\u00e1zek<\/li>\n<\/ul>\n<p><strong>Se\u010dteno A Podtr\u017eeno<\/strong>: Spr\u00e1vn\u00e1 jisti\u010d v\u00fdb\u011br chr\u00e1n\u00ed v\u00e1\u0161 elektrick\u00fd syst\u00e9m, zaji\u0161\u0165uje k\u00f3du shody, a zabra\u0148uje nebezpe\u010dn\u00fdm situac\u00edm. Kdy\u017e jste na pochyb\u00e1ch, pora\u010fte se s kvalifikovan\u00fdm elektrick\u00e9 profesion\u00e1ln\u00ed, aby bylo zaji\u0161t\u011bno bezpe\u010dn\u00e9 a spr\u00e1vn\u00e9 instalace.<\/p>\n<\/div>\n<div><\/div>","protected":false},"excerpt":{"rendered":"<p>Circuit breakers are essential safety devices that protect electrical circuits from overloads and short circuits. The main difference between SP, TP, TPN, and 4P circuit breakers lies in the number of poles and their applications: SP (Single Pole) for 120V single-phase circuits, TP (Triple Pole) for 240V\/480V three-phase circuits without neutral protection, TPN (Triple Pole [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":19119,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-19117","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts\/19117","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/comments?post=19117"}],"version-history":[{"count":0,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts\/19117\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media\/19119"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media?parent=19117"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/categories?post=19117"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/tags?post=19117"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}