{"id":19049,"date":"2025-08-01T14:31:23","date_gmt":"2025-08-01T06:31:23","guid":{"rendered":"https:\/\/viox.com\/?p=19049"},"modified":"2025-08-01T14:31:25","modified_gmt":"2025-08-01T06:31:25","slug":"fixed-type-vs-drawout-type-acb","status":"publish","type":"post","link":"https:\/\/test.viox.com\/cs\/fixed-type-vs-drawout-type-acb\/","title":{"rendered":"Pevn\u00fd typ vs. v\u00fdsuvn\u00fd typ ACB"},"content":{"rendered":"<div class=\"product-intro\">\n<p><strong>Hlavn\u00ed rozd\u00edl mezi pevn\u00fdm a v\u00fdsuvn\u00fdm typem <a href=\"https:\/\/test.viox.com\/cs\/complete-guide-to-air-circuit-breakers-acb\/\">vzduchov\u00e9 jisti\u010de (ACB)<\/a> je, \u017ee jisti\u010de pevn\u00e9ho typu jsou trvale namontov\u00e1ny v elektrick\u00e9m rozvad\u011b\u010di a vy\u017eaduj\u00ed jeho otev\u0159en\u00ed pro \u00fadr\u017ebu, zat\u00edmco jisti\u010de v\u00fdsuvn\u00e9ho typu lze snadno vyjmout z pouzdra pomoc\u00ed vysouvac\u00edho mechanismu bez naru\u0161en\u00ed elektrick\u00fdch spoj\u016f.<\/strong><\/p>\n<p>Pochopen\u00ed tohoto z\u00e1sadn\u00edho rozd\u00edlu je kl\u00ed\u010dov\u00e9 pro elektrotechniky, spr\u00e1vce budov a \u00fadr\u017eb\u00e1\u0159e p\u0159i v\u00fdb\u011bru spr\u00e1vn\u00e9ho typu jisti\u010de pro jejich elektrick\u00e9 distribu\u010dn\u00ed syst\u00e9my. Tato komplexn\u00ed p\u0159\u00edru\u010dka v\u00e1m pom\u016f\u017ee \u010dinit informovan\u00e1 rozhodnut\u00ed na z\u00e1klad\u011b va\u0161ich specifick\u00fdch po\u017eadavk\u016f na aplikaci, pot\u0159eb \u00fadr\u017eby a bezpe\u010dnostn\u00edch aspekt\u016f.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-19053\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/viox-ACB.webp\" alt=\"VIOX ACB\" width=\"800\" height=\"410\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/viox-ACB.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/viox-ACB-300x154.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/viox-ACB-768x394.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/viox-ACB-18x9.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/viox-ACB-600x308.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h2>Co jsou jisti\u010de pevn\u00e9ho a v\u00fdsuvn\u00e9ho typu?<\/h2>\n<h3>Definice ACB s pevn\u00fdm typem<\/h3>\n<p><img decoding=\"async\" class=\"alignnone  wp-image-19052\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/Fixed-Type-ACB-structure.webp\" alt=\"Fixed Type ACB structure\" width=\"682\" height=\"420\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/Fixed-Type-ACB-structure.webp 942w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/Fixed-Type-ACB-structure-300x185.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/Fixed-Type-ACB-structure-768x473.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/Fixed-Type-ACB-structure-18x12.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/Fixed-Type-ACB-structure-600x369.webp 600w\" sizes=\"(max-width: 682px) 100vw, 682px\" \/><\/p>\n<p>A <strong>pevn\u00fd vzduchov\u00fd jisti\u010d<\/strong> je trvale instalov\u00e1n v elektrick\u00e9m panelu nebo rozvad\u011b\u010di. T\u011bleso jisti\u010de je bezpe\u010dn\u011b upevn\u011bno pomoc\u00ed upev\u0148ovac\u00edch konzol a mechanick\u00fdch upev\u0148ovac\u00edch prvk\u016f, co\u017e z n\u011bj \u010din\u00ed ned\u00edlnou sou\u010d\u00e1st elektrick\u00e9ho rozvodn\u00e9ho syst\u00e9mu. V\u0161echna elektrick\u00e1 p\u0159ipojen\u00ed jsou provedena p\u0159\u00edmo na svork\u00e1ch jisti\u010de a jednotku nelze vyjmout bez odpojen\u00ed t\u011bchto p\u0159ipojen\u00ed.<\/p>\n<h3>Definice v\u00fdsuvn\u00e9ho typu jisti\u010de<\/h3>\n<p><img decoding=\"async\" class=\"alignnone  wp-image-19051\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/Drawout-Type-ACB-Structure.webp\" alt=\"Drawout Type ACB Structure\" width=\"632\" height=\"466\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/Drawout-Type-ACB-Structure.webp 932w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/Drawout-Type-ACB-Structure-300x221.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/Drawout-Type-ACB-Structure-768x567.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/Drawout-Type-ACB-Structure-16x12.webp 16w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/Drawout-Type-ACB-Structure-600x443.webp 600w\" sizes=\"(max-width: 632px) 100vw, 632px\" \/><\/p>\n<p>A <strong>v\u00fdsuvn\u00fd vzduchov\u00fd jisti\u010d<\/strong> Je vybaven vyj\u00edmateln\u00fdm jistic\u00edm prvkem um\u00edst\u011bn\u00fdm v samostatn\u00e9m mechanismu kol\u00e9bky nebo z\u00e1suvky. Jisti\u010d lze snadno vyjmout z provozn\u00ed polohy pomoc\u00ed rukojeti, co\u017e umo\u017e\u0148uje \u00fadr\u017ebu, testov\u00e1n\u00ed nebo v\u00fdm\u011bnu bez naru\u0161en\u00ed hlavn\u00edch elektrick\u00fdch p\u0159ipojen\u00ed k syst\u00e9mu.<\/p>\n<h2>Kl\u00ed\u010dov\u00e9 rozd\u00edly mezi jisti\u010di pevn\u00e9ho a v\u00fdsuvn\u00e9ho typu<\/h2>\n<p>Zde je komplexn\u00ed srovn\u00e1vac\u00ed tabulka ukazuj\u00edc\u00ed kl\u00ed\u010dov\u00e9 rozd\u00edly:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Funkce<\/th>\n<th>Pevn\u00fd typ jisti\u010de<\/th>\n<th>V\u00fdsuvn\u00fd typ ACB<\/th>\n<\/tr>\n<tr>\n<td><strong>Zp\u016fsob instalace<\/strong><\/td>\n<td>Trvale p\u0159i\u0161roubov\u00e1no k panelu<\/td>\n<td>Zasune se do odn\u00edmateln\u00e9 kol\u00e9bky<\/td>\n<\/tr>\n<tr>\n<td><strong>P\u0159\u00edstup k \u00fadr\u017eb\u011b<\/strong><\/td>\n<td>Vy\u017eaduje otev\u0159en\u00ed a odpojen\u00ed panelu<\/td>\n<td>Lze odebrat bez odpojen\u00ed<\/td>\n<\/tr>\n<tr>\n<td><strong>Doba v\u00fdm\u011bny<\/strong><\/td>\n<td>2\u20134 hodiny s prostoji<\/td>\n<td>15\u201330 minut s minim\u00e1ln\u00ed prostoji<\/td>\n<\/tr>\n<tr>\n<td><strong>Po\u010d\u00e1te\u010dn\u00ed n\u00e1klady<\/strong><\/td>\n<td>Ni\u017e\u0161\u00ed (20-30% levn\u011bj\u0161\u00ed)<\/td>\n<td>Vy\u0161\u0161\u00ed d\u00edky reg\u00e1lov\u00e9mu mechanismu<\/td>\n<\/tr>\n<tr>\n<td><strong>Po\u017eadavky na prostor<\/strong><\/td>\n<td>Kompaktn\u00ed, minim\u00e1ln\u00ed hloubka<\/td>\n<td>Vy\u017eaduje dodate\u010dnou hloubku pro sta\u017een\u00ed<\/td>\n<\/tr>\n<tr>\n<td><strong>Elektrick\u00e1 p\u0159ipojen\u00ed<\/strong><\/td>\n<td>P\u0159\u00edm\u00e9 p\u0159ipojen\u00ed termin\u00e1l\u016f<\/td>\n<td>Z\u00e1suvn\u00e9 kontakty s izola\u010dn\u00edmi desti\u010dkami<\/td>\n<\/tr>\n<tr>\n<td><strong>Bezpe\u010dnost b\u011bhem \u00fadr\u017eby<\/strong><\/td>\n<td>Vy\u0161\u0161\u00ed riziko v d\u016fsledku vystaven\u00ed \u017eiv\u00fdm \u010d\u00e1stem<\/td>\n<td>Zv\u00fd\u0161en\u00e1 bezpe\u010dnost s mechanick\u00fdm blokov\u00e1n\u00edm<\/td>\n<\/tr>\n<tr>\n<td><strong>Testovac\u00ed schopnosti<\/strong><\/td>\n<td>Pouze testov\u00e1n\u00ed na m\u00edst\u011b<\/td>\n<td>Lze testovat samostatn\u011b po odebr\u00e1n\u00ed<\/td>\n<\/tr>\n<tr>\n<td><strong>Typick\u00e9 aplikace<\/strong><\/td>\n<td>Reziden\u010dn\u00ed, lehk\u00e9 komer\u010dn\u00ed<\/td>\n<td>Pr\u016fmyslov\u00e9, kritick\u00e9 komer\u010dn\u00ed syst\u00e9my<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Rozd\u00edly v mechanick\u00e9 struktu\u0159e<\/h3>\n<p><strong>Komponenty pevn\u00e9ho typu:<\/strong><\/p>\n<ul>\n<li>Dr\u017e\u00e1ky pro mont\u00e1\u017e na panel<\/li>\n<li>Mechanick\u00fd ovl\u00e1dac\u00ed mechanismus<\/li>\n<li>Termin\u00e1ly pro p\u0159\u00edm\u00e9 p\u0159ipojen\u00ed<\/li>\n<li>Tla\u010d\u00edtko pro rozbit\u00ed\/vytvo\u0159en\u00ed<\/li>\n<li>Mechanismus ukl\u00e1d\u00e1n\u00ed energie<\/li>\n<li>Mechanismus spou\u0161t\u011b<\/li>\n<\/ul>\n<p><strong>Komponenty v\u00fdsuvn\u00e9ho typu:<\/strong><\/p>\n<ul>\n<li>T\u011bleso jisti\u010de s rukojet\u00ed pro zasunut\u00ed<\/li>\n<li>Dno z\u00e1suvky s vodic\u00edmi li\u0161tami<\/li>\n<li>Zvedac\u00ed rukojeti (lev\u00e9 a prav\u00e9)<\/li>\n<li>Izola\u010dn\u00ed deska pro bezpe\u010dnost<\/li>\n<li>Extern\u00ed pevn\u00e9 kontakty<\/li>\n<li>Mechanick\u00fd blokovac\u00ed syst\u00e9m<\/li>\n<\/ul>\n<h2>Aplikace a p\u0159\u00edpady pou\u017eit\u00ed<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-19054\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/application-of-ACB.webp\" alt=\"application of ACB\" width=\"800\" height=\"808\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/application-of-ACB.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/application-of-ACB-297x300.webp 297w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/application-of-ACB-768x776.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/application-of-ACB-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/application-of-ACB-600x606.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/08\/application-of-ACB-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h3>Kdy zvolit jisti\u010de s pevn\u00fdm typem<\/h3>\n<p><strong>Ide\u00e1ln\u00ed aplikace:<\/strong><\/p>\n<ul>\n<li>Elektrick\u00e9 rozvad\u011b\u010de pro dom\u00e1cnosti<\/li>\n<li>Mal\u00e9 komer\u010dn\u00ed budovy<\/li>\n<li>Projekty s ohledem na rozpo\u010det<\/li>\n<li>Aplikace s \u010dast\u00fdmi pot\u0159ebami \u00fadr\u017eby<\/li>\n<li>Prostorov\u011b omezen\u00e9 instalace<\/li>\n<li>Jednoduch\u00e9 elektrick\u00e9 rozvodn\u00e9 syst\u00e9my<\/li>\n<\/ul>\n<p><strong>Specifick\u00e9 p\u0159\u00edpady pou\u017eit\u00ed:<\/strong><\/p>\n<ul>\n<li>Kancel\u00e1\u0159sk\u00e9 budovy do 10 000 \u010dtvere\u010dn\u00edch stop<\/li>\n<li>Maloobchodn\u00ed prodejny a restaurace<\/li>\n<li>Obytn\u00e9 komplexy<\/li>\n<li>Vzd\u011bl\u00e1vac\u00ed za\u0159\u00edzen\u00ed se z\u00e1kladn\u00edmi elektrick\u00fdmi pot\u0159ebami<\/li>\n<\/ul>\n<h3>Kdy zvolit v\u00fdsuvn\u00fd typ jisti\u010d\u016f<\/h3>\n<p><strong>Ide\u00e1ln\u00ed aplikace:<\/strong><\/p>\n<ul>\n<li>Pr\u016fmyslov\u00e1 v\u00fdrobn\u00ed za\u0159\u00edzen\u00ed<\/li>\n<li>Nemocnice a zdravotnick\u00e1 za\u0159\u00edzen\u00ed<\/li>\n<li>Datov\u00e1 centra a telekomunikace<\/li>\n<li>Syst\u00e9my kritick\u00e9 infrastruktury<\/li>\n<li>Prost\u0159ed\u00ed s vysok\u00fdmi n\u00e1roky na \u00fadr\u017ebu<\/li>\n<li>Syst\u00e9my vy\u017eaduj\u00edc\u00ed \u010dast\u00e9 testov\u00e1n\u00ed<\/li>\n<\/ul>\n<p><strong>Specifick\u00e9 p\u0159\u00edpady pou\u017eit\u00ed:<\/strong><\/p>\n<ul>\n<li>V\u00fdrobn\u00ed z\u00e1vody s nep\u0159etr\u017eit\u00fdm provozem<\/li>\n<li>Kritick\u00e1 za\u0159\u00edzen\u00ed vy\u017eaduj\u00edc\u00ed vysokou provozuschopnost<\/li>\n<li>Za\u0159\u00edzen\u00ed se specializovan\u00fdmi \u00fadr\u017eb\u00e1\u0159sk\u00fdmi t\u00fdmy<\/li>\n<li>Syst\u00e9my podl\u00e9haj\u00edc\u00ed \u010dast\u00fdm elektrick\u00fdm test\u016fm<\/li>\n<li>Prost\u0159ed\u00ed s n\u00e1ro\u010dn\u00fdmi provozn\u00edmi podm\u00ednkami<\/li>\n<\/ul>\n<h2>\u00davahy o instalaci a \u00fadr\u017eb\u011b<\/h2>\n<h3>Proces instalace pevn\u00e9ho typu<\/h3>\n<ol>\n<li><strong>P\u0159\u00edprava panelu:<\/strong> Zajist\u011bte spr\u00e1vn\u00fd mont\u00e1\u017en\u00ed povrch a mezery<\/li>\n<li><strong>Mechanick\u00e1 mont\u00e1\u017e:<\/strong> Zajist\u011bte jisti\u010d pomoc\u00ed dodan\u00fdch dr\u017e\u00e1k\u016f<\/li>\n<li><strong>Elektrick\u00e1 p\u0159ipojen\u00ed:<\/strong> P\u0159ipojte p\u0159\u00edchoz\u00ed a odchoz\u00ed kabely p\u0159\u00edmo<\/li>\n<li><strong>Testov\u00e1n\u00ed:<\/strong> Prov\u00e1d\u011bjte provozn\u00ed a elektrick\u00e9 zkou\u0161ky<\/li>\n<li><strong>Uveden\u00ed do provozu:<\/strong> Kompletn\u00ed syst\u00e9mov\u00e1 integrace a dokumentace<\/li>\n<\/ol>\n<blockquote><p><strong>\u26a0\ufe0f Bezpe\u010dnostn\u00ed upozorn\u011bn\u00ed:<\/strong> Instalace pevn\u00e9ho typu vy\u017eaduje pr\u00e1ci s \u010d\u00e1stmi pod nap\u011bt\u00edm. V\u017edy dodr\u017eujte postupy zamyk\u00e1n\u00ed\/ozna\u010dov\u00e1n\u00ed a vyu\u017eijte slu\u017eeb kvalifikovan\u00fdch elektrik\u00e1\u0159\u016f.<\/p><\/blockquote>\n<h3>Proces instalace v\u00fdsuvn\u00e9ho typu<\/h3>\n<ol>\n<li><strong>Instalace kol\u00e9bky:<\/strong> Namontujte pevnou kol\u00e9bku do panelu<\/li>\n<li><strong>Elektrick\u00e1 p\u0159ipojen\u00ed:<\/strong> P\u0159ipojen\u00ed k pevn\u00e9mu kontaktn\u00edmu syst\u00e9mu<\/li>\n<li><strong>Vlo\u017een\u00ed jisti\u010de:<\/strong> Pro vlo\u017een\u00ed jisti\u010de pou\u017eijte rukoje\u0165<\/li>\n<li><strong>Ov\u011b\u0159en\u00ed pozice:<\/strong> Zajist\u011bte spr\u00e1vnou polohu \u201eP\u0159ipojeno\u201c<\/li>\n<li><strong>Mechanick\u00e9 blokov\u00e1n\u00ed:<\/strong> Ov\u011b\u0159te funkci v\u0161ech bezpe\u010dnostn\u00edch blokovac\u00edch za\u0159\u00edzen\u00ed<\/li>\n<li><strong>Testov\u00e1n\u00ed:<\/strong> Prove\u010fte testy vyta\u017een\u00ed a zasunut\u00ed<\/li>\n<\/ol>\n<h3>Porovn\u00e1n\u00ed po\u017eadavk\u016f na \u00fadr\u017ebu<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u00dadr\u017eb\u00e1\u0159sk\u00e1 \u010dinnost<\/th>\n<th>Pevn\u00fd typ<\/th>\n<th>Typ v\u00fdsuvn\u00e9ho<\/th>\n<\/tr>\n<tr>\n<td><strong>Rutinn\u00ed kontrola<\/strong><\/td>\n<td>Vy\u017eadov\u00e1n otvor v panelu<\/td>\n<td>Vyt\u00e1hn\u011bte pro snadn\u00fd p\u0159\u00edstup<\/td>\n<\/tr>\n<tr>\n<td><strong>\u010ci\u0161t\u011bn\u00ed kontakt\u016f<\/strong><\/td>\n<td>Pouze \u010di\u0161t\u011bn\u00ed na m\u00edst\u011b<\/td>\n<td>Pro d\u016fkladn\u00e9 \u010di\u0161t\u011bn\u00ed vyjm\u011bte<\/td>\n<\/tr>\n<tr>\n<td><strong>Kalibra\u010dn\u00ed testov\u00e1n\u00ed<\/strong><\/td>\n<td>Omezen\u00e9 testov\u00e1n\u00ed na m\u00edst\u011b<\/td>\n<td>Pln\u00e1 zku\u0161ebn\u00ed kapacita na lavi\u010dce<\/td>\n<\/tr>\n<tr>\n<td><strong>V\u00fdm\u011bna d\u00edl\u016f<\/strong><\/td>\n<td>Vy\u017eadov\u00e1no vypnut\u00ed syst\u00e9mu<\/td>\n<td>V mnoha p\u0159\u00edpadech vym\u011bniteln\u00e9 za provozu<\/td>\n<\/tr>\n<tr>\n<td><strong>Ro\u010dn\u00ed doba \u00fadr\u017eby<\/strong><\/td>\n<td>4\u20136 hodin<\/td>\n<td>2\u20133 hodiny<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Krit\u00e9ria v\u00fdb\u011bru a rozhodovac\u00ed r\u00e1mec<\/h2>\n<h3>R\u00e1mec anal\u00fdzy n\u00e1klad\u016f a p\u0159\u00ednos\u016f<\/h3>\n<p><strong>Zvolte pevn\u00fd typ, kdy\u017e:<\/strong><\/p>\n<ul>\n<li>Po\u010d\u00e1te\u010dn\u00ed rozpo\u010det je prim\u00e1rn\u00edm z\u00e1jmem<\/li>\n<li>Frekvence \u00fadr\u017eby je n\u00edzk\u00e1 (ro\u010dn\u00ed nebo m\u00e9n\u011b)<\/li>\n<li>Prostoje z d\u016fvodu \u00fadr\u017eby jsou p\u0159ijateln\u00e9<\/li>\n<li>Prostor je omezen\u00fd<\/li>\n<li>Aplikace nen\u00ed kritick\u00e1<\/li>\n<\/ul>\n<p><strong>Vyberte typ v\u00fdsuvu, kdy\u017e:<\/strong><\/p>\n<ul>\n<li>Provozuschopnost syst\u00e9mu je kritick\u00e1<\/li>\n<li>Vy\u017eaduje se \u010dast\u00e1 \u00fadr\u017eba nebo testov\u00e1n\u00ed<\/li>\n<li>Bezpe\u010dnost je prvo\u0159ad\u00fdm z\u00e1jmem<\/li>\n<li>Rozpo\u010det umo\u017e\u0148uje vy\u0161\u0161\u00ed po\u010d\u00e1te\u010dn\u00ed investici<\/li>\n<li>Dlouhodob\u00e9 provozn\u00ed n\u00e1klady jsou prioritou<\/li>\n<\/ul>\n<h3>Technick\u00e1 krit\u00e9ria v\u00fdb\u011bru<\/h3>\n<p><strong>Elektrick\u00e9 po\u017eadavky:<\/strong><\/p>\n<ul>\n<li>Jmenovit\u00e9 proudy: Oba typy jsou k dispozici v proveden\u00edch 800 A a\u017e 6300 A<\/li>\n<li>Jmenovit\u00e9 nap\u011bt\u00ed: A\u017e 690 V AC pro oba typy<\/li>\n<li>Vyp\u00ednac\u00ed schopnost: Srovnateln\u00e9 \u00farovn\u011b v\u00fdkonu<\/li>\n<li>Po\u017eadavky na koordinaci: Oba spl\u0148uj\u00ed pot\u0159eby selektivn\u00ed koordinace<\/li>\n<\/ul>\n<p><strong>Faktory prost\u0159ed\u00ed:<\/strong><\/p>\n<ul>\n<li>Okoln\u00ed teplota: Ob\u011b jsou vhodn\u00e9 pro standardn\u00ed podm\u00ednky<\/li>\n<li>Odolnost proti vlhkosti: V\u00fdsuvn\u00fd typ nab\u00edz\u00ed lep\u0161\u00ed ochranu<\/li>\n<li>Prach\/zne\u010di\u0161t\u011bn\u00ed: V\u00fdsuvn\u00fd typ se snadn\u011bji udr\u017euje<\/li>\n<li>Odolnost proti vibrac\u00edm: Pevn\u00fd typ m\u016f\u017ee m\u00edt m\u00edrnou v\u00fdhodu<\/li>\n<\/ul>\n<h2>Bezpe\u010dnostn\u00ed po\u017eadavky a shoda s p\u0159edpisy<\/h2>\n<h3>Shoda s n\u00e1rodn\u00edmi elektrotechnick\u00fdmi p\u0159edpisy (NEC)<\/h3>\n<p>Jisti\u010de pevn\u00e9ho i v\u00fdsuvn\u00e9ho typu mus\u00ed spl\u0148ovat:<\/p>\n<ul>\n<li><strong>\u010cl\u00e1nek 240 NEC:<\/strong> Po\u017eadavky na ochranu proti nadproudu<\/li>\n<li><strong>\u010cl\u00e1nek 490 NEC:<\/strong> Za\u0159\u00edzen\u00ed nad 1000 volt\u016f (pokud je to relevantn\u00ed)<\/li>\n<li><strong>NEMA AB 1:<\/strong> Normy pro vzduchov\u00e9 jisti\u010de<\/li>\n<li><strong>IEEE C37.16:<\/strong> Standard pro vzduchov\u00e9 sp\u00edna\u010de, podp\u011bry sb\u011brnice a p\u0159\u00edslu\u0161enstv\u00ed<\/li>\n<\/ul>\n<h3>Porovn\u00e1n\u00ed bezpe\u010dnostn\u00edch prvk\u016f<\/h3>\n<p><strong>Bezpe\u010dnostn\u00ed prvky pevn\u00e9ho typu:<\/strong><\/p>\n<ul>\n<li>Ru\u010dn\u00ed ovl\u00e1dac\u00ed p\u00e1ka s jasnou indikac\u00ed ZAP\/VYP<\/li>\n<li>Indikace mechanick\u00e9ho vypnut\u00ed<\/li>\n<li>Komora pro zadr\u017eov\u00e1n\u00ed oblouku<\/li>\n<li>Omezen\u00ed zkratov\u00e9ho proudu<\/li>\n<\/ul>\n<p><strong>Bezpe\u010dnostn\u00ed prvky v\u00fdsuvn\u00e9ho typu:<\/strong><\/p>\n<ul>\n<li>V\u0161echny prvky pevn\u00e9ho typu PLUS:<\/li>\n<li>Mechanick\u00e9 blokov\u00e1n\u00ed zabra\u0148uje nebezpe\u010dn\u00e9mu provozu<\/li>\n<li>Izola\u010dn\u00ed deska pro \u00fapln\u00e9 elektrick\u00e9 odd\u011blen\u00ed<\/li>\n<li>Indikace polohy (P\u0159ipojeno\/Test\/Odpojeno)<\/li>\n<li>Bezpe\u010dnostn\u00ed z\u00e1mky rukojeti reg\u00e1lu<\/li>\n<\/ul>\n<blockquote><p><strong>\u26a0\ufe0f Doporu\u010den\u00ed profesion\u00e1la:<\/strong> Instalace p\u0159esahuj\u00edc\u00ed 1000 A nebo kritick\u00e9 aplikace v\u017edy konzultujte s certifikovan\u00fdmi elektrotechniky.<\/p><\/blockquote>\n<h2>Anal\u00fdza n\u00e1klad\u016f a aspekty n\u00e1vratnosti investic<\/h2>\n<h3>Porovn\u00e1n\u00ed po\u010d\u00e1te\u010dn\u00edch investic<\/h3>\n<table>\n<tbody>\n<tr>\n<th>N\u00e1kladov\u00fd faktor<\/th>\n<th>Pevn\u00fd typ<\/th>\n<th>Typ v\u00fdsuvn\u00e9ho<\/th>\n<\/tr>\n<tr>\n<td><strong>Cena jisti\u010de<\/strong><\/td>\n<td>$2,000-$8,000<\/td>\n<td>$2,500-$12,000<\/td>\n<\/tr>\n<tr>\n<td><strong>Instala\u010dn\u00ed pr\u00e1ce<\/strong><\/td>\n<td>$500-$1,000<\/td>\n<td>$800-$1,500<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00dapravy panel\u016f<\/strong><\/td>\n<td>Minim\u00e1ln\u00ed<\/td>\n<td>M\u016f\u017ee vy\u017eadovat hlub\u0161\u00ed panely<\/td>\n<\/tr>\n<tr>\n<td><strong>Celkov\u00e9 po\u010d\u00e1te\u010dn\u00ed n\u00e1klady<\/strong><\/td>\n<td>Ni\u017e\u0161\u00ed o 20-30%<\/td>\n<td>Vy\u0161\u0161\u00ed po\u010d\u00e1te\u010dn\u00ed investice<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Dlouhodob\u00e9 provozn\u00ed n\u00e1klady<\/h3>\n<p><strong>Celkov\u00e9 n\u00e1klady na vlastnictv\u00ed pevn\u00e9ho typu:<\/strong><\/p>\n<ul>\n<li>Vy\u0161\u0161\u00ed n\u00e1klady na pr\u00e1ci v \u00fadr\u017eb\u011b<\/li>\n<li>Del\u0161\u00ed prostoje syst\u00e9mu<\/li>\n<li>Potenci\u00e1ln\u00ed ztr\u00e1ta p\u0159\u00edjm\u016f b\u011bhem \u00fadr\u017eby<\/li>\n<li>Omezen\u00e9 testovac\u00ed mo\u017enosti<\/li>\n<\/ul>\n<p><strong>Typ v\u00fdsuvn\u00e9ho Celkov\u00e9 n\u00e1klady na vlastnictv\u00ed:<\/strong><\/p>\n<ul>\n<li>Ni\u017e\u0161\u00ed n\u00e1klady na \u00fadr\u017ebu<\/li>\n<li>Minim\u00e1ln\u00ed prostoje syst\u00e9mu<\/li>\n<li>Sn\u00ed\u017een\u00ed ztr\u00e1ty p\u0159\u00edjm\u016f<\/li>\n<li>Vylep\u0161en\u00e9 mo\u017enosti preventivn\u00ed \u00fadr\u017eby<\/li>\n<\/ul>\n<p><strong>\ud83d\udca1 Tip odborn\u00edka:<\/strong> U kritick\u00fdch aplikac\u00ed obvykle zkr\u00e1cen\u00e1 doba odst\u00e1vky v\u00fdsuvn\u00fdch jisti\u010d\u016f zaji\u0161\u0165uje n\u00e1vratnost investic do 3\u20135 let d\u00edky zamezen\u00ed v\u00fdrobn\u00edch ztr\u00e1t.<\/p>\n<h2>\u0158e\u0161en\u00ed b\u011b\u017en\u00fdch probl\u00e9m\u016f<\/h2>\n<h3>B\u011b\u017en\u00e9 probl\u00e9my s pevn\u00fdm typem<\/h3>\n<ul>\n<li><strong>Obt\u00ed\u017en\u00fd p\u0159\u00edstup k termin\u00e1l\u016fm:<\/strong> Pe\u010dliv\u011b si napl\u00e1nujte intervaly \u00fadr\u017eby<\/li>\n<li><strong>Omezen\u00e9 mo\u017enosti testov\u00e1n\u00ed:<\/strong> Pokud je to mo\u017en\u00e9, pou\u017e\u00edvejte p\u0159enosn\u00e9 testovac\u00ed za\u0159\u00edzen\u00ed<\/li>\n<li><strong>Vy\u0161\u0161\u00ed n\u00e1klady na prostoje:<\/strong> Zva\u017ete z\u00e1lo\u017en\u00ed syst\u00e9my pro kritick\u00e9 z\u00e1t\u011b\u017ee<\/li>\n<\/ul>\n<h3>\u010cast\u00e9 probl\u00e9my s v\u00fdsuvn\u00fdm typem<\/h3>\n<ul>\n<li><strong>Opot\u0159eben\u00ed reg\u00e1lov\u00e9ho mechanismu:<\/strong> Mechanismus ka\u017edoro\u010dn\u011b promaz\u00e1vejte dle pokyn\u016f v\u00fdrobce.<\/li>\n<li><strong>Probl\u00e9my s vyrovn\u00e1n\u00edm kontakt\u016f:<\/strong> Ov\u011b\u0159te spr\u00e1vnou polohu vlo\u017een\u00ed pomoc\u00ed mechanick\u00fdch indik\u00e1tor\u016f<\/li>\n<li><strong>Vy\u0161\u0161\u00ed slo\u017eitost:<\/strong> Zajist\u011bte \u0159\u00e1dn\u00e9 \u0161kolen\u00ed person\u00e1lu \u00fadr\u017eby<\/li>\n<\/ul>\n<h2>Stru\u010dn\u00fd pr\u016fvodce v\u00fdb\u011brem<\/h2>\n<h3>Zvolte pevn\u00fd typ jisti\u010de, pokud:<\/h3>\n<ul>\n<li>\u2705 Rozpo\u010det je hlavn\u00edm omezen\u00edm<\/li>\n<li>\u2705 N\u00edzk\u00e1 frekvence \u00fadr\u017eby je p\u0159ijateln\u00e1<\/li>\n<li>\u2705 Nekritick\u00e1 aplikace<\/li>\n<li>\u2705 Omezen\u00fd po\u010det m\u00edst<\/li>\n<li>\u2705 Jednoduch\u00fd elektrick\u00fd syst\u00e9m<\/li>\n<\/ul>\n<h3>Vyberte typ v\u00fdsuvn\u00e9ho jisti\u010de, pokud:<\/h3>\n<ul>\n<li>\u2705 Provozuschopnost syst\u00e9mu je kl\u00ed\u010dov\u00e1<\/li>\n<li>\u2705 Vy\u017eaduje \u010dastou \u00fadr\u017ebu<\/li>\n<li>\u2705 Bezpe\u010dnost je na prvn\u00edm m\u00edst\u011b<\/li>\n<li>\u2705 Dlouhodob\u00e1 optimalizace n\u00e1klad\u016f je \u017e\u00e1douc\u00ed<\/li>\n<li>\u2705 K dispozici je profesion\u00e1ln\u00ed \u00fadr\u017eb\u00e1\u0159sk\u00fd t\u00fdm<\/li>\n<\/ul>\n<h2>Po\u017eadavky na profesion\u00e1ln\u00ed instalaci<\/h2>\n<h3>Instalace pevn\u00e9ho typu:<\/h3>\n<ul>\n<li>Vy\u017eadov\u00e1n elektrik\u00e1\u0159 s licenc\u00ed<\/li>\n<li>Mo\u017enosti \u00fapravy panelu<\/li>\n<li>Dostate\u010dn\u00e9 standardn\u00ed elektrick\u00e9 n\u00e1\u0159ad\u00ed<\/li>\n<li>Instala\u010dn\u00ed okno 2\u20134 hodiny<\/li>\n<\/ul>\n<h3>Instalace typu v\u00fdsuvn\u00e9ho:<\/h3>\n<ul>\n<li>Doporu\u010duje se certifikovan\u00fd technik<\/li>\n<li>Vy\u017eaduje se specializovan\u00e9 reg\u00e1lov\u00e9 n\u00e1\u0159ad\u00ed<\/li>\n<li>Ov\u011b\u0159en\u00ed hloubky panelu je nezbytn\u00e9<\/li>\n<li>Instala\u010dn\u00ed okno 4\u20136 hodin<\/li>\n<\/ul>\n<p><strong>\u26a0\ufe0f Pozn\u00e1mka k dodr\u017eov\u00e1n\u00ed p\u0159edpis\u016f:<\/strong> Ve\u0161ker\u00e9 instalace jisti\u010d\u016f ACB mus\u00ed spl\u0148ovat m\u00edstn\u00ed elektrotechnick\u00e9 p\u0159edpisy a mus\u00ed b\u00fdt prov\u00e1d\u011bny licencovan\u00fdmi odborn\u00edky. Pro instalace p\u0159ekra\u010duj\u00edc\u00ed specifick\u00e9 jmenovit\u00e9 proudy mohou b\u00fdt vy\u017eadov\u00e1na povolen\u00ed.<\/p>\n<h2>\u010casto Kladen\u00e9 Ot\u00e1zky<\/h2>\n<h3>Co d\u011bl\u00e1 jisti\u010de v\u00fdsuvn\u00e9ho typu bezpe\u010dn\u011bj\u0161\u00edmi ne\u017e pevn\u00e9 typy?<\/h3>\n<p>V\u00fdsuvn\u00e9 jisti\u010de poskytuj\u00ed zv\u00fd\u0161enou bezpe\u010dnost d\u00edky mechanick\u00fdm blokovac\u00edm syst\u00e9m\u016fm, kter\u00e9 zabra\u0148uj\u00ed nebezpe\u010dn\u00e9mu provozu, izola\u010dn\u00edm desk\u00e1m, kter\u00e9 zcela odd\u011bluj\u00ed elektrick\u00e1 p\u0159ipojen\u00ed, a mo\u017enosti prov\u00e1d\u011bt \u00fadr\u017ebu mimo dosah \u010d\u00e1st\u00ed pod nap\u011bt\u00edm.<\/p>\n<h3>Mohu upgradovat jisti\u010d z pevn\u00e9ho typu na v\u00fdsuvn\u00fd?<\/h3>\n<p>Modernizace obvykle vy\u017eaduje \u00fapravy panelu pro ulo\u017een\u00ed hlub\u0161\u00edho v\u00fdsuvn\u00e9ho mechanismu a m\u016f\u017ee vy\u017eadovat odst\u00e1vku elektrick\u00e9ho syst\u00e9mu. Pom\u011br n\u00e1klad\u016f a p\u0159\u00ednos\u016f by m\u011bl b\u00fdt porovn\u00e1n s v\u00fdm\u011bnou cel\u00e9ho panelu.<\/p>\n<h3>Jak \u010dasto by se m\u011bla prov\u00e1d\u011bt \u00fadr\u017eba jisti\u010d\u016f bez ohledu na typ?<\/h3>\n<p>Pr\u016fmyslov\u00e9 normy doporu\u010duj\u00ed ka\u017edoro\u010dn\u00ed kontrolu a testov\u00e1n\u00ed a \u010dast\u011bj\u0161\u00ed \u00fadr\u017ebu v kritick\u00fdch aplikac\u00edch nebo v n\u00e1ro\u010dn\u00fdch podm\u00ednk\u00e1ch. V\u00fdsuvn\u00e9 jisti\u010de tuto \u00fadr\u017ebu v\u00fdrazn\u011b usnad\u0148uj\u00ed.<\/p>\n<h3>Jak\u00fd je typick\u00fd rozd\u00edl v \u017eivotnosti mezi pevn\u00fdmi a v\u00fdsuvn\u00fdmi jisti\u010di?<\/h3>\n<p>Oba typy maj\u00ed podobnou elektrickou \u017eivotnost (20\u201330 let), ale v\u00fdsuvn\u00e9 jisti\u010de \u010dasto vydr\u017e\u00ed d\u00e9le d\u00edky lep\u0161\u00ed dostupnosti pro \u00fadr\u017ebu a mo\u017enosti d\u016fkladn\u00e9ho \u010di\u0161t\u011bn\u00ed a kalibrace.<\/p>\n<h3>Jsou jisti\u010de v\u00fdsuvn\u00e9ho typu spolehliv\u011bj\u0161\u00ed ne\u017e jisti\u010de pevn\u00e9ho typu?<\/h3>\n<p>Spolehlivost elektrick\u00fdch komponent\u016f je srovnateln\u00e1, ale jisti\u010de v\u00fdsuvn\u00e9ho typu mohou vykazovat lep\u0161\u00ed dlouhodob\u00fd v\u00fdkon d\u00edky lep\u0161\u00edm mo\u017enostem \u00fadr\u017eby a men\u0161\u00edmu opot\u0159eben\u00ed d\u00edky snadn\u011bj\u0161\u00edmu servisu.<\/p>\n<h3>Jak\u00e9 prostorov\u00e9 po\u017eadavky bych m\u011bl\/a zv\u00e1\u017eit pro instalaci v\u00fdsuvn\u00e9ho typu?<\/h3>\n<p>V\u00fdsuvn\u00e9 jisti\u010de vy\u017eaduj\u00ed p\u0159ibli\u017en\u011b 30\u201345 cm dodate\u010dn\u00e9 hloubky za panelem pro prostor pro vyta\u017een\u00ed a tak\u00e9 dostate\u010dn\u00fd prostor pro bezpe\u010dnou pr\u00e1ci \u00fadr\u017eb\u00e1\u0159sk\u00e9ho person\u00e1lu.<\/p>\n<h3>Mohou b\u00fdt v\u00fdsuvn\u00e9 jisti\u010de vym\u011b\u0148ov\u00e1ny za provozu?<\/h3>\n<p>I kdy\u017e v\u00fdsuvn\u00e9 jisti\u010de lze za ur\u010dit\u00fdch podm\u00ednek vyt\u00e1hnout do \u201etestovac\u00ed\u201c polohy, jejich \u00fapln\u00e9 vyjmut\u00ed obvykle vy\u017eaduje odpojen\u00ed syst\u00e9mu od nap\u00e1jen\u00ed. V\u00fdm\u011bnu za provozu by m\u011bli prov\u00e1d\u011bt pouze kvalifikovan\u00ed technici dodr\u017euj\u00edc\u00ed specifick\u00e9 bezpe\u010dnostn\u00ed postupy.<\/p>\n<h3>Jak se srovn\u00e1vaj\u00ed n\u00e1klady na \u00fadr\u017ebu v pr\u016fb\u011bhu \u017eivotnosti za\u0159\u00edzen\u00ed?<\/h3>\n<p>V\u00fdsuvn\u00e9 jisti\u010de obvykle sni\u017euj\u00ed n\u00e1klady na \u00fadr\u017ebu o 30\u2013401 TP3T b\u011bhem sv\u00e9 \u017eivotnosti d\u00edky snadn\u011bj\u0161\u00edmu p\u0159\u00edstupu, zkr\u00e1cen\u00e9 pracovn\u00ed dob\u011b a lep\u0161\u00ed kvalit\u011b \u00fadr\u017eby, a to i p\u0159es vy\u0161\u0161\u00ed po\u010d\u00e1te\u010dn\u00ed investici.<\/p>\n<h2>Se\u010dteno A Podtr\u017eeno<\/h2>\n<p>Pro cenov\u011b dostupn\u00e9 a nekritick\u00e9 aplikace, kde je p\u0159ijateln\u00e1 doba provozuschopnosti z d\u016fvodu \u00fadr\u017eby, zvolte jisti\u010de s pevn\u00fdm typem. Pro kritick\u00e9 syst\u00e9my vy\u017eaduj\u00edc\u00ed vysokou provozuschopnost, \u010dastou \u00fadr\u017ebu nebo zv\u00fd\u0161en\u00e9 bezpe\u010dnostn\u00ed po\u017eadavky zvolte jisti\u010de s v\u00fdsuvn\u00fdm typem. Vy\u0161\u0161\u00ed po\u010d\u00e1te\u010dn\u00ed n\u00e1klady na v\u00fdsuvn\u00e9 jednotky jsou obvykle kompenzov\u00e1ny ni\u017e\u0161\u00edmi n\u00e1klady na \u00fadr\u017ebu a prostoji v pr\u016fmyslov\u00fdch a kritick\u00fdch komer\u010dn\u00edch aplikac\u00edch.<\/p>\n<p><strong>Pro n\u00e1vrh slo\u017eit\u00fdch elektrick\u00fdch syst\u00e9m\u016f a v\u00fdb\u011br jisti\u010d\u016f se pora\u010fte s certifikovan\u00fdmi elektrotechniky a dodr\u017eujte v\u0161echny platn\u00e9 elektrotechnick\u00e9 p\u0159edpisy a specifikace v\u00fdrobce.<\/strong><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The main difference between fixed type and drawout type air circuit breakers (ACBs) is that fixed type ACBs are permanently mounted within the electrical panel and require panel opening for maintenance, while drawout type ACBs can be easily removed from their housing using a racking mechanism without disturbing the electrical connections. Understanding this fundamental difference [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":19050,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-19049","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts\/19049","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/comments?post=19049"}],"version-history":[{"count":0,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts\/19049\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media\/19050"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media?parent=19049"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/categories?post=19049"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/tags?post=19049"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}