{"id":19005,"date":"2025-07-28T14:00:28","date_gmt":"2025-07-28T06:00:28","guid":{"rendered":"https:\/\/viox.com\/?p=19005"},"modified":"2025-07-28T14:00:31","modified_gmt":"2025-07-28T06:00:31","slug":"connection-of-dc-isolators","status":"publish","type":"post","link":"https:\/\/test.viox.com\/cs\/connection-of-dc-isolators\/","title":{"rendered":"P\u0159ipojen\u00ed DC izol\u00e1tor\u016f: Kompletn\u00ed pr\u016fvodce bezpe\u010dnou instalac\u00ed a zapojen\u00edm"},"content":{"rendered":"<div class=\"product-intro\">\n<p><strong>Spodn\u00ed \u0159\u00e1dek vp\u0159edu<\/strong>P\u0159ipojen\u00ed DC izol\u00e1toru vy\u017eaduje spr\u00e1vnou identifikaci svorek, spr\u00e1vnou polaritu zapojen\u00ed a shodu s bezpe\u010dnostn\u00edmi normami AS\/NZS 5033. DC kabely pou\u017e\u00edvaj\u00ed flexibiln\u00ed vodi\u010de t\u0159\u00eddy 5, kter\u00e9 mus\u00ed b\u00fdt spr\u00e1vn\u011b zakon\u010deny, aby se zabr\u00e1nilo poruch\u00e1m, a je t\u0159eba zv\u00e1\u017eit zakon\u010den\u00ed DC vodi\u010de ve svork\u00e1ch izol\u00e1toru (526.9.1).<\/p>\n<h2>Co jsou to DC izol\u00e1tory a pro\u010d z\u00e1le\u017e\u00ed na p\u0159ipojen\u00ed?<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-12197\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/viox-DC-Isolator-Switches.webp\" alt=\"viox DC Isolator Switches\" width=\"800\" height=\"436\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/viox-DC-Isolator-Switches.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/viox-DC-Isolator-Switches-300x164.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/viox-DC-Isolator-Switches-768x419.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/viox-DC-Isolator-Switches-18x10.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/viox-DC-Isolator-Switches-600x327.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/test.viox.com\/cs\/dc-isolator-switch\/\">DC izol\u00e1tor VIOX<\/a><\/p>\n<p>DC odpojova\u010d (naz\u00fdvan\u00fd tak\u00e9 DC odpojova\u010d) je bezpe\u010dnostn\u00ed za\u0159\u00edzen\u00ed, kter\u00e9 zaji\u0161\u0165uje \u00faplnou elektrickou izolaci v syst\u00e9mech stejnosm\u011brn\u00e9ho proudu, zejm\u00e9na v sol\u00e1rn\u00edch fotovoltaick\u00fdch instalac\u00edch. \u00dapln\u00fdm odpojen\u00edm zdroje energie, kdy\u017e je nutn\u00e1 \u00fadr\u017eba nebo opravy, zaji\u0161\u0165uje, \u017ee nikdo nebude zasa\u017een elektrick\u00fdm proudem, pokud se dostane do kontaktu s \u010d\u00e1st\u00ed syst\u00e9mu pod nap\u011bt\u00edm.<\/p>\n<blockquote><p><strong>\u26a0\ufe0f Bezpe\u010dnostn\u00ed Upozorn\u011bn\u00ed<\/strong>DC izol\u00e1tory byly zdrojem mnoha po\u017e\u00e1r\u016f a jsou hlavn\u00ed p\u0159\u00ed\u010dinou selh\u00e1n\u00ed sol\u00e1rn\u00edch fotovoltaick\u00fdch instalac\u00ed. Spr\u00e1vn\u00e9 p\u0159ipojen\u00ed a instalace jsou z\u00e1sadn\u00ed pro bezpe\u010dnost a v\u00fdkon syst\u00e9mu.<\/p><\/blockquote>\n<h3>Kl\u00ed\u010dov\u00e9 rozd\u00edly: Zapojen\u00ed izol\u00e1tor\u016f DC vs. AC<\/h3>\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"Ohromuj\u00edc\u00ed rozd\u00edl mezi odd\u011blova\u010di st\u0159\u00eddav\u00e9ho a stejnosm\u011brn\u00e9ho proudu!\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/YxHCDs03UEg?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<p>Stejnosm\u011brn\u00e9 izol\u00e1tory \u010del\u00ed ve srovn\u00e1n\u00ed s odd\u011blova\u010di st\u0159\u00eddav\u00e9ho proudu specifick\u00fdm probl\u00e9m\u016fm. U st\u0159\u00eddav\u00e9ho syst\u00e9mu pracuj\u00edc\u00edho na frekvenci 50 Hz nap\u011bt\u00ed dvakr\u00e1t za cyklus protne nulu, a to ka\u017ed\u00fdch 10 milisekund, co\u017e pom\u00e1h\u00e1 potla\u010dit elektrick\u00e9 oblouky. Stejnosm\u011brn\u00e9 nap\u011bt\u00ed je v\u0161ak konstantn\u00ed a toto prot\u00edn\u00e1n\u00ed nulou postr\u00e1d\u00e1, co\u017e zt\u011b\u017euje zhasnut\u00ed oblouku.<\/p>\n<h2>Po\u017eadavky a normy pro p\u0159ipojen\u00ed DC izol\u00e1toru<\/h2>\n<h3>Prim\u00e1rn\u00ed standardy a shoda<\/h3>\n<ul>\n<li><strong>AS\/NZS 5033:2021<\/strong>Instala\u010dn\u00ed a bezpe\u010dnostn\u00ed po\u017eadavky pro fotovoltaick\u00e1 pole<\/li>\n<li><strong>AS 60947.3:2018<\/strong>Upraven\u00e1 verze normy IEC 60947-3 s po\u017eadavky specifick\u00fdmi pro Austr\u00e1lii<\/li>\n<li><strong>IEC 60947-3<\/strong>Mezin\u00e1rodn\u00ed norma pro n\u00edzkonap\u011b\u0165ov\u00e9 rozv\u00e1d\u011b\u010de a \u0159\u00eddic\u00ed p\u0159\u00edstroje<\/li>\n<\/ul>\n<p>Odp\u00edna\u010de mus\u00ed nyn\u00ed spl\u0148ovat normu AS 60947.3:2018, co\u017e je upraven\u00e1 verze mezin\u00e1rodn\u00ed normy IEC 60947.3 s po\u017eadavky specifick\u00fdmi pro Austr\u00e1lii.<\/p>\n<h3>Z\u00e1kladn\u00ed specifikace p\u0159ipojen\u00ed<\/h3>\n<table>\n<thead>\n<tr>\n<th>Specifikace<\/th>\n<th>Po\u017eadavek<\/th>\n<th>Standardn\u00ed reference<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>T\u0159\u00edda dirigent\u016f<\/strong><\/td>\n<td>T\u0159\u00edda 5 (flexibiln\u00ed)<\/td>\n<td>AS\/NZS 5033<\/td>\n<\/tr>\n<tr>\n<td><strong>Ozna\u010den\u00ed svorek<\/strong><\/td>\n<td>Mus\u00ed vyhovovat v\u0161em t\u0159\u00edd\u00e1m dirigent\u016f<\/td>\n<td>526.2 Pozn\u00e1mka 2<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/test.viox.com\/cs\/ip67-vs-ip68\/\"><strong>Stupe\u0148 kryt\u00ed IP<\/strong><\/a><\/td>\n<td>Minim\u00e1ln\u00ed kryt\u00ed IP56NZ pro venkovn\u00ed pou\u017eit\u00ed<\/td>\n<td>AS 60947.3<\/td>\n<\/tr>\n<tr>\n<td><strong>Hodnocen\u00ed teploty<\/strong><\/td>\n<td>40 \u00b0C (ve st\u00ednu) \/ 60 \u00b0C (na obloze)<\/td>\n<td>AS\/NZS 5033:2021<\/td>\n<\/tr>\n<tr>\n<td><strong>Kategorie vyu\u017eit\u00ed<\/strong><\/td>\n<td>DC-PV2 pro fotovoltaick\u00e9 syst\u00e9my<\/td>\n<td>AS 60947.3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Postup p\u0159ipojen\u00ed DC izol\u00e1toru krok za krokem<\/h2>\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"Izol\u00e1tor stejnosm\u011brn\u00e9ho proudu - Zapojen\u00ed odpojova\u010de sol\u00e1rn\u00edch fotovoltaick\u00fdch panel\u016f\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/wO0p-2DwLzc?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<h3><strong>Krok 1: Bezpe\u010dnost a pl\u00e1nov\u00e1n\u00ed p\u0159ed p\u0159ipojen\u00edm<\/strong><\/h3>\n<blockquote><p><strong>\ud83d\udd27 Tip odborn\u00edka<\/strong>P\u0159ed zah\u00e1jen\u00edm jak\u00fdchkoli p\u0159ipojovac\u00edch prac\u00ed se v\u017edy ujist\u011bte, \u017ee je zdroj nap\u00e1jen\u00ed zcela izolov\u00e1n. Pomoc\u00ed multimetru ov\u011b\u0159te nulov\u00e9 nap\u011bt\u00ed na v\u0161ech svork\u00e1ch.<\/p><\/blockquote>\n<ol>\n<li>Vypn\u011bte v\u0161echny zdroje nap\u00e1jen\u00ed p\u0159ed za\u0159\u00edzen\u00edm<\/li>\n<li>Postupy uzam\u010den\u00ed\/ozna\u010den\u00ed (LOTO)<\/li>\n<li>Ov\u011b\u0159te izolaci pomoc\u00ed vhodn\u00e9ho testovac\u00edho za\u0159\u00edzen\u00ed<\/li>\n<li>Identifikujte kladn\u00e9 a z\u00e1porn\u00e9 vodi\u010de pomoc\u00ed spr\u00e1vn\u00e9ho ozna\u010den\u00ed kabel\u016f<\/li>\n<\/ol>\n<h3>Krok 2: Identifikace a p\u0159\u00edprava termin\u00e1lu<\/h3>\n<p>Kabely stejnosm\u011brn\u00e9ho proudu obvykle pou\u017e\u00edvaj\u00ed vodi\u010de t\u0159\u00eddy 5 (ohebn\u00e9). Pokud nejsou svorky za\u0159\u00edzen\u00ed ozna\u010deny, m\u011bly by b\u00fdt vhodn\u00e9 pro v\u0161echny t\u0159\u00eddy vodi\u010d\u016f bez \u00faprav.<\/p>\n<h4>Po\u017eadavky na p\u0159\u00edpravu termin\u00e1lu:<\/h4>\n<ul>\n<li>Odizolujte kabel podle specifikac\u00ed v\u00fdrobce<\/li>\n<li>Pokud je nutn\u00e9 o\u0161et\u0159en\u00ed vodi\u010d\u016f na zakon\u010den\u00ed, je t\u0159eba se odk\u00e1zat na \u00fadaje v\u00fdrobce, kter\u00e9 mohou uv\u00e1d\u011bt, \u017ee jemn\u00fd dr\u00e1tov\u00fd vodi\u010d vy\u017eaduje n\u00e1vlek nebo koncovku.<\/li>\n<li>Zajist\u011bte \u010dist\u00e9 a korozivzdorn\u00e9 povrchy svorek<\/li>\n<li>V p\u0159\u00edpad\u011b pot\u0159eby pou\u017eijte antioxida\u010dn\u00ed slo\u017eku.<\/li>\n<\/ul>\n<h3>Krok 3: Pochopen\u00ed konfigurac\u00ed p\u0159ipojen\u00ed<\/h3>\n<p>R\u016fzn\u00e9 typy DC izol\u00e1tor\u016f vy\u017eaduj\u00ed specifick\u00e9 konfigurace zapojen\u00ed na z\u00e1klad\u011b po\u017eadavk\u016f na nap\u011bt\u00ed a proud:<\/p>\n<h4>Standardn\u00ed mo\u017enosti konfigurace<\/h4>\n<table>\n<thead>\n<tr>\n<th>Konfigurace<\/th>\n<th>Nap\u011bt\u00ed<\/th>\n<th>Sou\u010dasn\u00e1 kapacita<\/th>\n<th>Aplikace<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>2p\u00f3lov\u00e1 \u0159ada<\/strong><\/td>\n<td>A\u017e 600 V<\/td>\n<td>Ni\u017e\u0161\u00ed proud<\/td>\n<td>Jednostrunn\u00e9 syst\u00e9my<\/td>\n<\/tr>\n<tr>\n<td><strong>4p\u00f3lov\u00e1 \u0159ada<\/strong><\/td>\n<td>A\u017e 1000 V<\/td>\n<td>St\u0159edn\u00ed proud<\/td>\n<td>Vysokonap\u011b\u0165ov\u00e1 pole<\/td>\n<\/tr>\n<tr>\n<td><strong>2p\u00f3lov\u00e9 s\u00e9riov\u00e9 + 2p\u00f3lov\u00e9 paraleln\u00ed<\/strong><\/td>\n<td>Prom\u011bnn\u00e1<\/td>\n<td>Vy\u0161\u0161\u00ed proud<\/td>\n<td>V\u00edcestrunn\u00e9 syst\u00e9my<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Pomoc\u00ed d\u0159\u00edve stanoven\u00fdch hodnot nap\u011bt\u00ed a proudu lze z tabulky 1 vybrat vhodnou konfiguraci zapojen\u00ed. Pro sp\u00edn\u00e1n\u00ed 15,6 A p\u0159i 936 V by m\u011bl b\u00fdt odpojova\u010d zapojen bu\u010f v 4p\u00f3lov\u00e9 s\u00e9riov\u00e9 konfiguraci, nebo v 2p\u00f3lov\u00e9 s\u00e9riov\u00e9 + 2p\u00f3lov\u00e9 paraleln\u00ed konfiguraci.<\/p>\n<h3>Krok 4: Proces fyzick\u00e9ho p\u0159ipojen\u00ed<\/h3>\n<p><strong>Pro standardn\u00ed 2p\u00f3lov\u00e9 DC izol\u00e1tory:<\/strong><\/p>\n<ol>\n<li>Identifikujte vstupn\u00ed a v\u00fdstupn\u00ed svorky (\u010dasto ozna\u010den\u00e9 L1\/L2 pro vstup, T1\/T2 pro v\u00fdstup)<\/li>\n<li>P\u0159ipojte kladn\u00fd vodi\u010d k ur\u010den\u00e9mu kladn\u00e9mu p\u00f3lu<\/li>\n<li>P\u0159ipojte z\u00e1porn\u00fd vodi\u010d k ur\u010den\u00e9mu z\u00e1porn\u00e9mu svorci<\/li>\n<li>Ut\u00e1hn\u011bte spoje podle utahovac\u00edho momentu uveden\u00e9ho v\u00fdrobcem<\/li>\n<li>P\u0159ed p\u0159ipojen\u00edm zkontrolujte polaritu<\/li>\n<\/ol>\n<blockquote><p><strong>\u26a0\ufe0f Kritick\u00e9 varov\u00e1n\u00ed<\/strong>P\u0159ipojen\u00ed je diagon\u00e1ln\u00ed, tak\u017ee p\u0159\u00edm\u00e9 zapojen\u00ed bude m\u00edt za n\u00e1sledek obr\u00e1cenou polaritu. V\u017edy ov\u011b\u0159te p\u0159ipojovac\u00ed cesty pomoc\u00ed testu kontinuity.<\/p><\/blockquote>\n<h3>Krok 5: Ov\u011b\u0159en\u00ed a testov\u00e1n\u00ed p\u0159ipojen\u00ed<\/h3>\n<p><strong>Z\u00e1kladn\u00ed kroky ov\u011b\u0159en\u00ed:<\/strong><\/p>\n<ol>\n<li>Vizu\u00e1ln\u00ed kontrola v\u0161ech spoj\u016f<\/li>\n<li>Testov\u00e1n\u00ed kontinuity s odpojova\u010dem v poloze ZAPNUTO<\/li>\n<li>M\u011b\u0159en\u00ed izola\u010dn\u00edho odporu s odpojova\u010dem v poloze VYPNUTO<\/li>\n<li>Ov\u011b\u0159en\u00ed polarity pomoc\u00ed vhodn\u00e9ho testovac\u00edho za\u0159\u00edzen\u00ed<\/li>\n<li>Provozn\u00ed zkou\u0161ka sp\u00ednac\u00edho mechanismu<\/li>\n<\/ol>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-15032\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/04\/Flame-retardant-shell-DC-isolator-switch.webp\" alt=\"Flame-retardant shell DC isolator switch\" width=\"800\" height=\"600\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/04\/Flame-retardant-shell-DC-isolator-switch.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/04\/Flame-retardant-shell-DC-isolator-switch-300x225.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/04\/Flame-retardant-shell-DC-isolator-switch-768x576.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/04\/Flame-retardant-shell-DC-isolator-switch-16x12.webp 16w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/04\/Flame-retardant-shell-DC-isolator-switch-600x450.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h2>Dimenzov\u00e1n\u00ed proudu a nap\u011bt\u00ed pro p\u0159ipojen\u00ed stejnosm\u011brn\u00e9ho izol\u00e1toru<\/h2>\n<h3>V\u00fdpo\u010det maxim\u00e1ln\u00edch po\u017eadavk\u016f na proud<\/h3>\n<p>P\u0159i v\u00fdb\u011bru za\u0159\u00edzen\u00ed pro FV panely, v\u010detn\u011b DC izol\u00e1tor\u016f, se pou\u017eije maxim\u00e1ln\u00ed zkratov\u00fd proud (ISC MAX) (712.512.1.2). Pro v\u00fdpo\u010det t\u00e9to hodnoty lze pou\u017e\u00edt vzorec 2: ISC MAX = Po\u010det \u0159et\u011bzc\u016f x ISC STC x 1,25<\/p>\n<p><strong>Kde:<\/strong><br \/>\nISC MAX = Maxim\u00e1ln\u00ed zkratov\u00fd proud pole<br \/>\nPo\u010det \u0159et\u011bzc\u016f = Celkov\u00fd po\u010det \u0159et\u011bzc\u016f zapojen\u00fdch paraleln\u011b<br \/>\nISC STC = Zkratov\u00fd proud za standardn\u00edch zku\u0161ebn\u00edch podm\u00ednek<br \/>\n1,25 = Bezpe\u010dnostn\u00ed multiplik\u00e1tor pro podm\u00ednky vy\u0161\u0161\u00edho oz\u00e1\u0159en\u00ed<\/p>\n<h3>Teplotn\u00ed aspekty<\/h3>\n<p>Pro izol\u00e1tory um\u00edst\u011bn\u00e9 uvnit\u0159 nebo venku v pln\u011b zast\u00edn\u011bn\u00e9m m\u00edst\u011b je specifikovan\u00e1 okoln\u00ed teplota 40 stup\u0148\u016f Celsia. Pro izol\u00e1tory um\u00edst\u011bn\u00e9 venku a vystaven\u00e9 slune\u010dn\u00edmu z\u00e1\u0159en\u00ed je specifikovan\u00e1 okoln\u00ed teplota 60 stup\u0148\u016f Celsia.<\/p>\n<h2>Typy DC izol\u00e1tor\u016f a metody p\u0159ipojen\u00ed<\/h2>\n<h3><strong>Typy odp\u00edna\u010d\u016f<\/strong><\/h3>\n<table>\n<thead>\n<tr>\n<th>Typ<\/th>\n<th>Zp\u016fsob p\u0159ipojen\u00ed<\/th>\n<th>Aplikace<\/th>\n<th>Kl\u00ed\u010dov\u00e9 vlastnosti<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Rota\u010dn\u00ed izol\u00e1tory<\/strong><\/td>\n<td>Konfigurace diagon\u00e1ln\u00edho termin\u00e1lu<\/td>\n<td>Sol\u00e1rn\u00ed fotovoltaick\u00e9 syst\u00e9my<\/td>\n<td>Kontakty s ostrou hranou, kryt\u00ed IP67<\/td>\n<\/tr>\n<tr>\n<td><strong>Odpojova\u010de z\u00e1t\u011b\u017ee<\/strong><\/td>\n<td>Standardn\u00ed svorkovnice<\/td>\n<td>Pr\u016fmyslov\u00e9 stejnosm\u011brn\u00e9 syst\u00e9my<\/td>\n<td>Vysok\u00e1 vyp\u00ednac\u00ed schopnost<\/td>\n<\/tr>\n<tr>\n<td><strong>Integrovan\u00e9 izol\u00e1tory<\/strong><\/td>\n<td>Mont\u00e1\u017e vnit\u0159n\u00edho st\u0159\u00edda\u010de<\/td>\n<td>Reziden\u010dn\u00ed sol\u00e1rn\u00ed energie<\/td>\n<td>Prostorov\u011b \u00fasporn\u00fd design<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>Prav\u00e9 stejnosm\u011brn\u00e9 vs. odd\u011blova\u010de st\u0159\u00eddav\u00e9ho proudu se sn\u00ed\u017een\u00fdm jmenovit\u00fdm v\u00fdkonem<\/strong><\/h3>\n<blockquote><p><strong>\ud83d\udd27 Tip odborn\u00edka<\/strong>IMO SI je sp\u00edna\u010d True DC \u2013 nikoli verze pro st\u0159\u00eddav\u00fd proud se sn\u00ed\u017een\u00fdm jmenovit\u00fdm v\u00fdkonem nebo p\u0159epojen\u00e1 pro provoz se stejnosm\u011brn\u00fdm proudem. Pro spolehliv\u00fd v\u00fdkon a bezpe\u010dnost v\u017edy specifikujte odd\u011blova\u010de True DC.<\/p><\/blockquote>\n<h4>Vlastnosti skute\u010dn\u00fdch stejnosm\u011brn\u00fdch izol\u00e1tor\u016f:<\/h4>\n<ul>\n<li>Specializovan\u00e9 komory pro zh\u00e1\u0161en\u00ed oblouku<\/li>\n<li>Kontaktn\u00ed materi\u00e1ly pro stejnosm\u011brn\u00e9 nap\u011bt\u00ed<\/li>\n<li>Schopnost odol\u00e1vat vy\u0161\u0161\u00edmu nap\u011bt\u00ed<\/li>\n<li>Teplotn\u011b odoln\u00e9 proveden\u00ed<\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-12196\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/DC-Isolator-Applications.webp\" alt=\"DC Isolator Applications\" width=\"800\" height=\"446\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/DC-Isolator-Applications.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/DC-Isolator-Applications-300x167.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/DC-Isolator-Applications-768x428.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/DC-Isolator-Applications-18x10.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/DC-Isolator-Applications-600x335.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h2>M\u00edsto instalace a po\u017eadavky na mont\u00e1\u017e<\/h2>\n<h3><strong>Po\u017eadavky na mont\u00e1\u017en\u00ed povrch<\/strong><\/h3>\n<p>Spole\u010dnost Energy Safe doporu\u010duje instalovat odpojova\u010d stejnosm\u011brn\u00e9ho proudu na neho\u0159lav\u00fd povrch. V p\u0159\u00edpadech, kdy je povrch ho\u0159lav\u00fd, <a href=\"https:\/\/www.standards.govt.nz\/shop\/asnzs-50332021\" rel=\"nofollow noopener\" target=\"_blank\">AS\/NZS 5033:2021<\/a> Bod 4.5.4.1 vy\u017eaduje neho\u0159lavou bari\u00e9ru mezi stejnosm\u011brn\u00fdm izol\u00e1torem a ho\u0159lav\u00fdm povrchem.<\/p>\n<h4>Specifikace neho\u0159lav\u00e9 bari\u00e9ry:<\/h4>\n<ul>\n<li>Mus\u00ed p\u0159esahovat 200 mm za strany izol\u00e1toru<\/li>\n<li>Protipo\u017e\u00e1rn\u00ed tmel pro prostupy o pr\u016fm\u011bru &gt; 5 mm<\/li>\n<li>Materi\u00e1ly spl\u0148uj\u00edc\u00ed normy AS 1530.1<\/li>\n<\/ul>\n<h3><strong>Kryt\u00ed IP a ochrana proti pov\u011btrnostn\u00edm vliv\u016fm<\/strong><\/h3>\n<p>Aby se sn\u00ed\u017eilo vniknut\u00ed vody a p\u0159ed\u010dasn\u00e9 selh\u00e1n\u00ed odpojova\u010de stejnosm\u011brn\u00e9ho proudu, mus\u00ed b\u00fdt spln\u011bny minim\u00e1ln\u00ed bezpe\u010dnostn\u00ed po\u017eadavky na instalaci v souladu s normou AS\/NZS 5033:2021, bod 4.4.7, v\u010detn\u011b: Odleh\u010den\u00ed tahu vodi\u010d\u016f (pokud se pro vstup do sk\u0159\u00edn\u011b nepou\u017e\u00edv\u00e1 trubka). Zachov\u00e1n\u00ed kryt\u00ed IP66 odpojova\u010de stejnosm\u011brn\u00e9ho proudu, pou\u017e\u00edvejte pouze vstupn\u00ed body od v\u00fdrobce.<\/p>\n<h2>B\u011b\u017en\u00e9 probl\u00e9my s p\u0159ipojen\u00edm a jejich \u0159e\u0161en\u00ed<\/h2>\n<h3><strong>\u010cast\u00e9 probl\u00e9my s p\u0159ipojen\u00edm<\/strong><\/h3>\n<table>\n<thead>\n<tr>\n<th>Probl\u00e9m<\/th>\n<th>P\u0159\u00ed\u010dina<\/th>\n<th>\u0158e\u0161en\u00ed<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Obr\u00e1cen\u00e1 polarita<\/strong><\/td>\n<td>Nespr\u00e1vn\u00e1 identifikace termin\u00e1lu<\/td>\n<td>Pou\u017eijte test kontinuity k ov\u011b\u0159en\u00ed cest p\u0159ipojen\u00ed<\/td>\n<\/tr>\n<tr>\n<td><strong>P\u0159eh\u0159\u00edv\u00e1n\u00ed svorek<\/strong><\/td>\n<td>Voln\u00e9 spoje<\/td>\n<td>Ut\u00e1hn\u011bte na specifikovan\u00e9 hodnoty utahovac\u00edho momentu<\/td>\n<\/tr>\n<tr>\n<td><strong>Po\u0161kozen\u00ed obloukem<\/strong><\/td>\n<td>Nespr\u00e1vn\u00e9 sp\u00edn\u00e1n\u00ed pod z\u00e1t\u011b\u017e\u00ed<\/td>\n<td>Dodr\u017eujte spr\u00e1vn\u00e9 po\u0159ad\u00ed sp\u00edn\u00e1n\u00ed<\/td>\n<\/tr>\n<tr>\n<td><strong>Vniknut\u00ed vody<\/strong><\/td>\n<td>\u0160patn\u00e9 ut\u011bsn\u011bn\u00ed kabelov\u00e9 pr\u016fchodky<\/td>\n<td>Pou\u017e\u00edvejte v\u00fdvodky s kryt\u00edm IP a pr\u016fchodky s v\u00edce otvory<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>Preventivn\u00ed strategie<\/strong><\/h3>\n<blockquote><p><strong>\ud83d\udd27 Tip odborn\u00edka<\/strong>Je d\u016fle\u017eit\u00e9 dodr\u017eovat pokyny v\u00fdrobce pro konfiguraci odpojova\u010de stejnosm\u011brn\u00e9ho proudu, aby se p\u0159ede\u0161lo selh\u00e1n\u00ed za\u0159\u00edzen\u00ed.<\/p><\/blockquote>\n<h4>Nejlep\u0161\u00ed postupy:<\/h4>\n<ul>\n<li>V\u017edy pou\u017e\u00edvejte kabelov\u00e9 vstupy schv\u00e1len\u00e9 v\u00fdrobcem<\/li>\n<li>Na v\u0161echna spojen\u00ed aplikujte spr\u00e1vn\u00e9 utahovac\u00ed momenty<\/li>\n<li>P\u0159ed p\u0159ipojen\u00edm obvod\u016f k nap\u00e1jen\u00ed zkontrolujte polaritu.<\/li>\n<li>Zav\u00e9st pravideln\u00e9 pl\u00e1ny kontrol<\/li>\n<\/ul>\n<h2>Bezpe\u010dnostn\u00ed normy a po\u017eadavky na certifikaci<\/h2>\n<h3><strong>Australsk\u00e9 regula\u010dn\u00ed po\u017eadavky<\/strong><\/h3>\n<p>Odd\u011blova\u010de stejnosm\u011brn\u00e9ho proudu jsou klasifikov\u00e1ny jako elektrick\u00e1 za\u0159\u00edzen\u00ed \u00farovn\u011b 3 a mus\u00ed b\u00fdt certifikov\u00e1ny a registrov\u00e1ny podle n\u00e1rodn\u00edch p\u0159edpis\u016f. <a href=\"https:\/\/www.eess.gov.au\/\" rel=\"nofollow noopener\" target=\"_blank\">Syst\u00e9m bezpe\u010dnosti elektrick\u00fdch za\u0159\u00edzen\u00ed (EESS)<\/a>.<\/p>\n<h4>Kl\u00ed\u010dov\u00e9 body shody:<\/h4>\n<ul>\n<li>Registrace EESS pro v\u0161echny DC odd\u011blova\u010de<\/li>\n<li>Soulad s normou AS 60947.3:2018<\/li>\n<li>Ov\u011b\u0159en\u00ed kryt\u00ed IP56NW<\/li>\n<li>Certifikace tepeln\u00e9 odolnosti p\u0159i 40 \u00b0C<\/li>\n<\/ul>\n<h3><strong>Instala\u010dn\u00ed dokumentace<\/strong><\/h3>\n<p>Dokumentace je d\u016fle\u017eit\u00fdm po\u017eadavkem uveden\u00fdm v instala\u010dn\u00edch norm\u00e1ch AS\/NZS 5033 a AS\/NZS 4777.1, kter\u00e9 mus\u00ed b\u00fdt dodr\u017eeny p\u0159i instalaci fotovoltaick\u00e9ho syst\u00e9mu.<\/p>\n<h2>Krit\u00e9ria v\u00fdb\u011bru DC izol\u00e1toru<\/h2>\n<h3><strong>V\u00fdb\u011br spr\u00e1vn\u00e9ho izol\u00e1toru<\/strong><\/h3>\n<p>P\u0159i v\u00fdb\u011bru DC izol\u00e1tor\u016f pro v\u00e1\u0161 syst\u00e9m zva\u017ete tyto kritick\u00e9 faktory:<\/p>\n<h4>Elektrick\u00e9 specifikace:<\/h4>\n<ul>\n<li>Maxim\u00e1ln\u00ed nap\u011bt\u00ed syst\u00e9mu (obvykle 600 V pro dom\u00e1cnosti, 1000 V pro firmy)<\/li>\n<li>Maxim\u00e1ln\u00ed zkratov\u00e1 proudov\u00e1 kapacita<\/li>\n<li>Prolomen\u00ed a vytvo\u0159en\u00ed aktu\u00e1ln\u00edch hodnocen\u00ed<\/li>\n<li>Kategorie u\u017eit\u00ed (DC-PV2 pro fotovoltaick\u00e9 syst\u00e9my)<\/li>\n<\/ul>\n<h4>Faktory prost\u0159ed\u00ed:<\/h4>\n<ul>\n<li>M\u00edsto instalace (vnit\u0159n\u00ed\/venkovn\u00ed)<\/li>\n<li>Vystaven\u00ed teplot\u011b (st\u00edn\/p\u0159\u00edm\u00e9 slune\u010dn\u00ed sv\u011btlo)<\/li>\n<li>Po\u017eadavky na kryt\u00ed IP<\/li>\n<li>Kompatibilita mont\u00e1\u017en\u00edho povrchu<\/li>\n<\/ul>\n<h3><strong>\u00davahy o n\u00e1kladech<\/strong><\/h3>\n<p>Cena DC odpojova\u010de je ve srovn\u00e1n\u00ed s cenou DC jisti\u010de obvykle ni\u017e\u0161\u00ed. P\u0159esn\u00e1 cena sp\u00edna\u010de v\u0161ak z\u00e1vis\u00ed na jeho velikosti a funkc\u00edch. Z\u00e1kladn\u00ed modely mohou za\u010d\u00ednat na cen\u011b kolem $20, zat\u00edmco v\u011bt\u0161\u00ed a dra\u017e\u0161\u00ed modely mohou st\u00e1t a\u017e $200.<\/p>\n<h2>\u010casto kladen\u00e9 ot\u00e1zky o p\u0159ipojen\u00ed DC izol\u00e1toru<\/h2>\n<h3><strong>\u010c\u00edm se li\u0161\u00ed p\u0159ipojen\u00ed stejnosm\u011brn\u00e9ho izol\u00e1toru od p\u0159ipojen\u00ed st\u0159\u00eddav\u00e9ho proudu?<\/strong><\/h3>\n<p>Stejnosm\u011brn\u00e9 nap\u011bt\u00ed je konstantn\u00ed a chyb\u00ed mu k\u0159\u00ed\u017een\u00ed nulov\u00e9ho bodu, co\u017e zt\u011b\u017euje zh\u00e1\u0161en\u00ed oblouku. To vy\u017eaduje specializovan\u00e9 kontaktn\u00ed materi\u00e1ly a zh\u00e1\u0161ec\u00ed komory v odd\u011blova\u010d\u00edch stejnosm\u011brn\u00e9ho proudu, kter\u00e9 nejsou v aplikac\u00edch se st\u0159\u00eddav\u00fdm proudem pot\u0159eba.<\/p>\n<h3><strong>Mohu pou\u017e\u00edt odd\u011blova\u010d st\u0159\u00eddav\u00e9ho proudu pro aplikace se stejnosm\u011brn\u00fdm proudem?<\/strong><\/h3>\n<p>Ne. Odpojova\u010de stejnosm\u011brn\u00e9ho proudu jsou speci\u00e1ln\u011b navr\u017eeny pro stejnosm\u011brn\u00e9 nap\u00e1jec\u00ed syst\u00e9my. Pro st\u0159\u00eddav\u00e9 syst\u00e9my je nutn\u00e9 pou\u017e\u00edt odpojova\u010de ur\u010den\u00e9 pro st\u0159\u00eddav\u00fd proud. Pou\u017eit\u00ed nespr\u00e1vn\u00e9ho typu m\u016f\u017ee v\u00e9st k nebezpe\u010dn\u00fdm poruch\u00e1m a nebezpe\u010d\u00ed po\u017e\u00e1ru.<\/p>\n<h3><strong>Jak\u00e9 typy kabel\u016f by se m\u011bly pou\u017e\u00edvat s DC izol\u00e1tory?<\/strong><\/h3>\n<p>Stejnosm\u011brn\u00e9 kabely obvykle pou\u017e\u00edvaj\u00ed vodi\u010de t\u0159\u00eddy 5 (flexibiln\u00ed). Ty poskytuj\u00ed lep\u0161\u00ed flexibilitu a spolehlivost ve fotovoltaick\u00fdch instalac\u00edch ve srovn\u00e1n\u00ed s pln\u00fdmi vodi\u010di.<\/p>\n<h3><strong>Jak po p\u0159ipojen\u00ed ov\u011b\u0159\u00edm spr\u00e1vnou polaritu?<\/strong><\/h3>\n<p>Prove\u010fte test kontinuity s odpojova\u010dem v poloze ON a ov\u011b\u0159te, zda p\u0159ipojovac\u00ed cesta odpov\u00edd\u00e1 zam\u00fd\u0161len\u00e9 polarit\u011b obvodu. P\u0159ipojen\u00ed jsou diagon\u00e1ln\u00ed, tak\u017ee p\u0159\u00edm\u00e9 zapojen\u00ed bude m\u00edt za n\u00e1sledek obr\u00e1cenou polaritu.<\/p>\n<h3><strong>Jak\u00e9 kryt\u00ed IP je vy\u017eadov\u00e1no pro venkovn\u00ed DC odd\u011blova\u010de?<\/strong><\/h3>\n<p>Pro venkovn\u00ed izol\u00e1tory v jednotliv\u00fdch sk\u0159\u00edn\u00edch je vy\u017eadov\u00e1n minim\u00e1ln\u00ed stupe\u0148 kryt\u00ed (IP) IP56NW.<\/p>\n<h3><strong>Vy\u017eaduj\u00ed DC izol\u00e1tory zvl\u00e1\u0161tn\u00ed mont\u00e1\u017en\u00ed opat\u0159en\u00ed?<\/strong><\/h3>\n<p>Ano. Spole\u010dnost Energy Safe doporu\u010duje instalovat DC izol\u00e1tor na neho\u0159lav\u00fd povrch a zajistit \u0159\u00e1dn\u00e9 odleh\u010den\u00ed tahu a ochranu p\u0159ed pov\u011btrnostn\u00edmi vlivy v souladu s normou AS\/NZS 5033:2021.<\/p>\n<h2>Doporu\u010den\u00ed pro profesion\u00e1ln\u00ed instalaci a \u00fadr\u017ebu<\/h2>\n<h3><strong>Kdy najmout profesion\u00e1ln\u00ed elektrik\u00e1\u0159e<\/strong><\/h3>\n<p>I kdy\u017e se z\u00e1kladn\u00ed zapojen\u00ed DC odd\u011blova\u010d\u016f m\u016f\u017ee zd\u00e1t jednoduch\u00e9, doporu\u010duje se profesion\u00e1ln\u00ed instalace pro:<\/p>\n<ul>\n<li>Syst\u00e9my nad 48 V DC<\/li>\n<li>Komer\u010dn\u00ed a pr\u016fmyslov\u00e9 instalace<\/li>\n<li>Slo\u017eit\u00e9 v\u00edce\u0159et\u011bzcov\u00e9 konfigurace<\/li>\n<li>Po\u017eadavky na certifikaci shody<\/li>\n<\/ul>\n<h3><strong>Harmonogram \u00fadr\u017eby<\/strong><\/h3>\n<p><strong>Ro\u010dn\u00ed kontroly by m\u011bly zahrnovat:<\/strong><\/p>\n<ul>\n<li>Vizu\u00e1ln\u00ed kontrola spoj\u016f, zda nejsou patrn\u00e9 zn\u00e1mky p\u0159eh\u0159\u00e1t\u00ed<\/li>\n<li>Ov\u011b\u0159en\u00ed integrity kryt\u00ed IP<\/li>\n<li>Provozn\u00ed zkou\u0161ka sp\u00ednac\u00edho mechanismu<\/li>\n<li>Ov\u011b\u0159en\u00ed utahovac\u00edho momentu pro p\u0159ipojen\u00ed svorek<\/li>\n<li>Aktualizace dokumentace dle pot\u0159eby<\/li>\n<\/ul>\n<p><strong>Kl\u00ed\u010dov\u00e9 shrnut\u00ed<\/strong>Spr\u00e1vn\u00e9 p\u0159ipojen\u00ed DC odd\u011blova\u010de vy\u017eaduje pochopen\u00ed specializovan\u00fdch po\u017eadavk\u016f na DC sp\u00edn\u00e1n\u00ed, dodr\u017eov\u00e1n\u00ed aktu\u00e1ln\u00edch bezpe\u010dnostn\u00edch norem a pozornost v\u011bnovanou kritick\u00fdm detail\u016fm, jako je identifikace svorek a ov\u011b\u0159en\u00ed polarity. V\u017edy up\u0159ednost\u0148ujte bezpe\u010dnost a u slo\u017eit\u00fdch syst\u00e9m\u016f nebo v p\u0159\u00edpad\u011b nejistoty ohledn\u011b specifick\u00fdch po\u017eadavk\u016f zva\u017ete odbornou instalaci.<\/p>\n<p><strong>Pro profesion\u00e1ln\u00ed instalaci<\/strong>: Obra\u0165te se na licencovan\u00e9ho elektrik\u00e1\u0159e obezn\u00e1men\u00e9ho s po\u017eadavky normy AS\/NZS 5033:2021 a syst\u00e9my stejnosm\u011brn\u00e9 izolace, abyste zajistili bezpe\u010dnou a kompatibiln\u00ed instalaci, kter\u00e1 chr\u00e1n\u00ed jak person\u00e1l, tak za\u0159\u00edzen\u00ed.<\/p>\n<h2>Souvisej\u00edc\u00ed<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/cs\/what-is-a-dc-isolator-switch\/\">Co je stejnosm\u011brn\u00fd izola\u010dn\u00ed sp\u00edna\u010d<\/a><\/p>\n<p><a href=\"https:\/\/test.viox.com\/cs\/how-to-choose-the-right-dc-isolator-switcha-complete-guide\/\">Jak vybrat spr\u00e1vn\u00fd stejnosm\u011brn\u00fd izol\u00e1tor: kompletn\u00ed pr\u016fvodce<\/a><\/p>\n<p><a href=\"https:\/\/test.viox.com\/cs\/global-dc-isolator-switch-trend-why-more-companies-are-choosing-chinese-suppliers\/\">Glob\u00e1ln\u00ed trend sp\u00edna\u010d\u016f stejnosm\u011brn\u00e9ho proudu: Pro\u010d si st\u00e1le v\u00edce spole\u010dnost\u00ed vyb\u00edr\u00e1 \u010d\u00ednsk\u00e9 dodavatele<\/a><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Bottom Line Up Front: DC isolator connection requires proper terminal identification, correct polarity wiring, and compliance with AS\/NZS 5033 safety standards. DC cables use Class 5 flexible conductors that must be terminated correctly to prevent failures, and consideration should be given to the termination of the DC conductor in the isolator&#8217;s terminals (526.9.1). What Are [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":19014,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-19005","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts\/19005","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/comments?post=19005"}],"version-history":[{"count":0,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts\/19005\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media\/19014"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media?parent=19005"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/categories?post=19005"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/tags?post=19005"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}