{"id":18585,"date":"2025-07-18T14:40:19","date_gmt":"2025-07-18T06:40:19","guid":{"rendered":"https:\/\/viox.com\/?p=18585"},"modified":"2025-07-18T14:40:21","modified_gmt":"2025-07-18T06:40:21","slug":"can-junction-boxes-be-behind-drywall","status":"publish","type":"post","link":"https:\/\/test.viox.com\/cs\/can-junction-boxes-be-behind-drywall\/","title":{"rendered":"Mohou b\u00fdt rozvodn\u00e9 krabice za s\u00e1drokartonov\u00fdmi deskami"},"content":{"rendered":"<div class=\"product-intro\"><strong>P\u0159\u00edm\u00e1 odpov\u011b\u010f:<\/strong> Ne, rozvodn\u00e9 krabice nelze zcela skr\u00fdt za s\u00e1drokartonem. Podle N\u00e1rodn\u00edho elektrotechnick\u00e9ho p\u0159edpisu (NEC) mus\u00ed b\u00fdt v\u0161echny rozvodn\u00e9 krabice p\u0159\u00edstupn\u00e9 bez nutnosti demont\u00e1\u017ee jak\u00e9koli \u010d\u00e1sti stavebn\u00ed konstrukce nebo povrchov\u00fdch materi\u00e1l\u016f. Tento kritick\u00fd bezpe\u010dnostn\u00ed po\u017eadavek zabra\u0148uje \u00farazu elektrick\u00fdm proudem a zaji\u0161\u0165uje \u0159\u00e1dn\u00fd p\u0159\u00edstup pro \u00fadr\u017ebu.<\/div>\n<div class=\"product-intro\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-18587\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/wire-under-drywall.webp\" alt=\"wire under drywall\" width=\"800\" height=\"427\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/wire-under-drywall.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/wire-under-drywall-300x160.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/wire-under-drywall-768x410.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/wire-under-drywall-18x10.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/wire-under-drywall-600x320.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Pochopen\u00ed po\u017eadavk\u016f na p\u0159\u00edstupnost rozvodn\u00fdch krabic je nezbytn\u00e9 pro bezpe\u010dnou elektroinstalaci, dodr\u017eov\u00e1n\u00ed p\u0159edpis\u016f a vyhnut\u00ed se n\u00e1kladn\u00fdm oprav\u00e1m. A\u0165 u\u017e jste majitel domu pl\u00e1nuj\u00edc\u00ed rekonstrukci, nebo profesion\u00e1ln\u00ed elektrik\u00e1\u0159, tato p\u0159\u00edru\u010dka v\u00e1m poskytne v\u0161e, co pot\u0159ebujete v\u011bd\u011bt o spr\u00e1vn\u00e9m um\u00edst\u011bn\u00ed rozvodn\u00fdch krabic a po\u017eadavc\u00edch na p\u0159\u00edstup.<\/p>\n<h2>Co jsou rozvodn\u00e9 krabice a pro\u010d je d\u016fle\u017eit\u00e1 p\u0159\u00edstupnost<\/h2>\n<p><img decoding=\"async\" class=\"alignnone  wp-image-4248\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/Waterproof-Junction-Box-Series.webp\" alt=\"\" width=\"547\" height=\"547\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/Waterproof-Junction-Box-Series.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/Waterproof-Junction-Box-Series-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/Waterproof-Junction-Box-Series-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/Waterproof-Junction-Box-Series-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/Waterproof-Junction-Box-Series-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/Waterproof-Junction-Box-Series-100x100.webp 100w\" sizes=\"(max-width: 547px) 100vw, 547px\" \/><\/p>\n<p>A<a href=\"https:\/\/test.viox.com\/cs\/junction-box-manufacturer\/\"> rozvodn\u00e1 krabice<\/a> je elektrick\u00e1 sk\u0159\u00ed\u0148, kter\u00e1 obsahuje vodi\u010dov\u00e9 spoje, spojky nebo elektrick\u00e1 za\u0159\u00edzen\u00ed. Tyto sk\u0159\u00edn\u011b slou\u017e\u00ed jako kritick\u00e9 bezpe\u010dnostn\u00ed komponenty t\u00edm, \u017ee:<\/p>\n<ul>\n<li>Obsahuj\u00edc\u00ed elektrick\u00e9 oblouky a jiskry<\/li>\n<li>Ochrana vodi\u010dov\u00fdch spoj\u016f p\u0159ed fyzick\u00fdm po\u0161kozen\u00edm<\/li>\n<li>Zabr\u00e1n\u011bn\u00ed \u0161\u00ed\u0159en\u00ed elektrick\u00fdch po\u017e\u00e1r\u016f<\/li>\n<li>Zaji\u0161t\u011bn\u00ed organizovan\u00fdch p\u0159\u00edstupov\u00fdch bod\u016f pro elektrick\u00e9 syst\u00e9my<\/li>\n<\/ul>\n<p><strong>Pro\u010d mus\u00ed rozvodn\u00e9 krabice z\u016fstat p\u0159\u00edstupn\u00e9:<\/strong><\/p>\n<p>Norma NEC na\u0159izuje p\u0159\u00edstupnost, proto\u017ee elektrick\u00e9 spoje mohou \u010dasem selhat a vy\u017eadovat kontrolu, \u00fadr\u017ebu nebo opravu. Skryt\u00e9 rozvodn\u00e9 krabice vytv\u00e1\u0159ej\u00ed nebezpe\u010dn\u00e9 situace, kdy:<\/p>\n<ul>\n<li>Vadn\u00e9 spoje nelze rychle identifikovat<\/li>\n<li>Nouzov\u00e1 vypnut\u00ed se st\u00e1vaj\u00ed nemo\u017en\u00fdmi<\/li>\n<li>Nebezpe\u010d\u00ed po\u017e\u00e1ru z\u016fst\u00e1v\u00e1 neodhaleno<\/li>\n<li>\u0158e\u0161en\u00ed probl\u00e9m\u016f s elektrick\u00fdmi za\u0159\u00edzen\u00edmi se st\u00e1v\u00e1 extr\u00e9mn\u011b obt\u00ed\u017en\u00fdm<\/li>\n<\/ul>\n<h2>Po\u017eadavky NEC Code pro p\u0159\u00edstupnost rozvodn\u00fdch sk\u0159\u00edn\u00ed<\/h2>\n<h3>\u010cl\u00e1nek 314.29: Po\u017eadavky na p\u0159\u00edstup k rozvodn\u00e9 sk\u0159\u00edni<\/h3>\n<p>N\u00e1rodn\u00ed elektrotechnick\u00fd p\u0159edpis jasn\u011b uv\u00e1d\u00ed, <a href=\"https:\/\/up.codes\/s\/boxes-conduit-bodies-and-handhole-enclosures-to-be-accessible\" rel=\"nofollow noopener\" target=\"_blank\">\u010cl\u00e1nek 314.29<\/a> \u017ee rozvodn\u00e9 krabice mus\u00ed b\u00fdt p\u0159\u00edstupn\u00e9. To znamen\u00e1:<\/p>\n<p><strong>Definice \u201ep\u0159\u00edstupn\u00e9ho\u201c podle NEC:<\/strong><\/p>\n<ul>\n<li>P\u0159izn\u00e1n\u00ed bl\u00edzk\u00e9ho p\u0159ibl\u00ed\u017een\u00ed<\/li>\n<li>Nen\u00ed trvale uzav\u0159eno konstrukc\u00ed budovy<\/li>\n<li>Nevy\u017eaduje demont\u00e1\u017e panel\u016f, dve\u0159\u00ed nebo podobn\u00fdch stavebn\u00edch prvk\u016f<\/li>\n<li>Snadno dostupn\u00fd pro kontrolu a \u00fadr\u017ebu<\/li>\n<\/ul>\n<h3>Kl\u00ed\u010dov\u00e9 body souladu s p\u0159edpisy<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Po\u017eadavek<\/th>\n<th>Sekce k\u00f3du<\/th>\n<th>Praktick\u00e9 pou\u017eit\u00ed<\/th>\n<\/tr>\n<tr>\n<td>Mus\u00ed b\u00fdt p\u0159\u00edstupn\u00e9<\/td>\n<td>314.29<\/td>\n<td>S\u00e1drokartonov\u00e9 oblo\u017een\u00ed nen\u00ed povoleno<\/td>\n<\/tr>\n<tr>\n<td>Za odn\u00edmateln\u00fdmi panely<\/td>\n<td>314.29 V\u00fdjimka<\/td>\n<td>Pouze panely sk\u0159\u00edn\u011bk nebo armatur<\/td>\n<\/tr>\n<tr>\n<td>Spr\u00e1vn\u00e9 ozna\u010den\u00ed\/\u0161t\u00edtky<\/td>\n<td>110.22<\/td>\n<td>Vy\u017eaduje se jasn\u00e1 identifikace<\/td>\n<\/tr>\n<tr>\n<td>Vy\u010di\u0161t\u011bn\u00ed pracovn\u00edho prostoru<\/td>\n<td>110.26<\/td>\n<td>Minim\u00e1ln\u00ed p\u0159\u00edstupov\u00fd prostor 30 palc\u016f<\/td>\n<\/tr>\n<tr>\n<td>Uzemn\u011bn\u00ed za\u0159\u00edzen\u00ed<\/td>\n<td>250.148<\/td>\n<td>Spr\u00e1vn\u00e1 kontinuita uzemn\u011bn\u00ed<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<blockquote>\n<p><strong>\u26a0\ufe0f Bezpe\u010dnostn\u00ed upozorn\u011bn\u00ed:<\/strong> Zakr\u00fdv\u00e1n\u00ed rozvodn\u00fdch krabic s\u00e1drokartonem poru\u0161uje elektrotechnick\u00e9 p\u0159edpisy a p\u0159edstavuje v\u00e1\u017en\u00e9 nebezpe\u010d\u00ed po\u017e\u00e1ru a \u00farazu elektrick\u00fdm proudem. Pro elektroinstala\u010dn\u00ed pr\u00e1ce se v\u017edy pora\u010fte s kvalifikovan\u00fdm elektrik\u00e1\u0159em.<\/p>\n<\/blockquote>\n<h2>Co d\u011bl\u00e1 rozvodnou krabici \u201ep\u0159\u00edstupnou\u201c vs. \u201eskrytou\u201c<\/h2>\n<p>Pochopen\u00ed rozd\u00edlu mezi p\u0159\u00edstupn\u00fdmi a skryt\u00fdmi instalacemi je kl\u00ed\u010dov\u00e9 pro dodr\u017eov\u00e1n\u00ed p\u0159edpis\u016f:<\/p>\n<h3>Po\u017eadavky na p\u0159\u00edstupnou instalaci<\/h3>\n<p><strong>Spr\u00e1vn\u00e9 metody p\u0159\u00edstupu:<\/strong><\/p>\n<ol>\n<li><strong>Krabice pro povrchovou mont\u00e1\u017e<\/strong> na hotov\u00fdch st\u011bn\u00e1ch<\/li>\n<li><strong>Zapu\u0161t\u011bn\u00e9 krabice<\/strong> s odn\u00edmateln\u00fdmi kryc\u00edmi deskami<\/li>\n<li><strong>Krabice za odn\u00edmateln\u00fdmi panely<\/strong> (dve\u0159e sk\u0159\u00edn\u011bk, p\u0159\u00edstupov\u00e9 panely)<\/li>\n<li><strong>Stropn\u00ed krabice<\/strong> s rozbalovac\u00edm p\u0159\u00edstupem<\/li>\n<li><strong>Instalace v suter\u00e9nu nebo v prol\u00e9zac\u00edm prostoru<\/strong> s voln\u00fdmi cestami<\/li>\n<\/ol>\n<h3>Zak\u00e1zan\u00e9 skryt\u00e9 instalace<\/h3>\n<p><strong>Mezi poru\u0161en\u00ed kodexu pat\u0159\u00ed:<\/strong><\/p>\n<ul>\n<li>Rozvodn\u00e9 krabice kompletn\u011b zas\u00e1drokartonem<\/li>\n<li>Krabice za trvale upevn\u011bn\u00fdmi st\u011bnami<\/li>\n<li>Za\u0159\u00edzen\u00ed vy\u017eaduj\u00edc\u00ed demolici pro p\u0159\u00edstup<\/li>\n<li>Krabice pokryt\u00e9 podlahov\u00fdmi nebo stropn\u00edmi materi\u00e1ly<\/li>\n<li>Skryt\u00e9 spoje bez \u0159\u00e1dn\u00e9ho krytu rozvodn\u00e9 krabice<\/li>\n<\/ul>\n<h2>Porovn\u00e1n\u00ed: Bezbari\u00e9rov\u00e1 vs. skryt\u00e1 instalace rozvodn\u00e9 krabice<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Aspekt<\/th>\n<th>Bezbari\u00e9rov\u00e1 instalace<\/th>\n<th>Skryt\u00e1 instalace<\/th>\n<\/tr>\n<tr>\n<td><strong>K\u00f3d Souladu<\/strong><\/td>\n<td>\u2705 V souladu s normami NEC<\/td>\n<td>\u274c Poru\u0161en\u00ed kodexu<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00darove\u0148 bezpe\u010dnosti<\/strong><\/td>\n<td>\u2705 Vysok\u00e1 \u2013 Snadn\u00e1 kontrola<\/td>\n<td>\u274c Nebezpe\u010dn\u00e9 \u2013 P\u0159\u00edstup zak\u00e1z\u00e1n<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00dadr\u017eba<\/strong><\/td>\n<td>\u2705 Jednoduch\u00e9 opravy\/modernizace<\/td>\n<td>\u274c Vy\u017eaduje demolici<\/td>\n<\/tr>\n<tr>\n<td><strong>Po\u017e\u00e1rn\u00ed bezpe\u010dnost<\/strong><\/td>\n<td>\u2705 Rychl\u00e1 identifikace probl\u00e9mu<\/td>\n<td>\u274c Skryt\u00e1 nebezpe\u010d\u00ed po\u017e\u00e1ru<\/td>\n<\/tr>\n<tr>\n<td><strong>Pojistn\u00e9 kryt\u00ed<\/strong><\/td>\n<td>\u2705 Pln\u00e9 kryt\u00ed<\/td>\n<td>\u274c M\u016f\u017ee zru\u0161it n\u00e1roky<\/td>\n<\/tr>\n<tr>\n<td><strong>Hodnota p\u0159i dal\u0161\u00edm prodeji<\/strong><\/td>\n<td>\u2705 Zvy\u0161uje hodnotu domu<\/td>\n<td>\u274c Sni\u017euje prodejnost<\/td>\n<\/tr>\n<tr>\n<td><strong>Shoda s inspek\u010dn\u00edmi po\u017eadavky<\/strong><\/td>\n<td>\u2705 Proch\u00e1z\u00ed elektrorevizemi<\/td>\n<td>\u274c Neprojde inspekcemi<\/td>\n<\/tr>\n<tr>\n<td><strong>Profesion\u00e1ln\u00ed instalace<\/strong><\/td>\n<td>\u2705 Spl\u0148uje normy pro elektrik\u00e1\u0159e<\/td>\n<td>\u274c Vy\u017eaduje korekci<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Spr\u00e1vn\u00e1 \u0159e\u0161en\u00ed um\u00edst\u011bn\u00ed rozvodn\u00e9 krabice<\/h2>\n<h3>Mo\u017enost 1: Povrchov\u00e1 mont\u00e1\u017e<\/h3>\n<p><strong>Nejlep\u0161\u00ed pro:<\/strong> Dokon\u010den\u00e9 sklepy, technick\u00e9 m\u00edstnosti, komer\u010dn\u00ed prostory<\/p>\n<p><strong>Proces instalace:<\/strong><\/p>\n<ol>\n<li>Namontujte rozvodnou krabici p\u0159\u00edmo na povrch zdi<\/li>\n<li>Nainstalujte vhodnou kryc\u00ed desku<\/li>\n<li>Zajist\u011bte pracovn\u00ed prostor 30 palc\u016f (76 cm)<\/li>\n<li>Jasn\u011b ozna\u010dte obsah krabice<\/li>\n<li>Dodr\u017eujte spr\u00e1vnou d\u00e9lku vodi\u010d\u016f<\/li>\n<\/ol>\n<h3>Mo\u017enost 2: Zapu\u0161t\u011bn\u00e9 za p\u0159\u00edstupov\u00e9 panely<\/h3>\n<p><strong>Nejlep\u0161\u00ed pro:<\/strong> Obytn\u00e9 prostory vy\u017eaduj\u00edc\u00ed estetick\u00e9 aspekty<\/p>\n<p><strong>Po\u017eadavky:<\/strong><\/p>\n<ul>\n<li>Pouze odn\u00edmateln\u00e9 p\u0159\u00edstupov\u00e9 panely<\/li>\n<li>K demont\u00e1\u017ei panelu nen\u00ed pot\u0159eba \u017e\u00e1dn\u00e9 n\u00e1\u0159ad\u00ed<\/li>\n<li>Jasn\u00e9 ozna\u010den\u00ed elektrick\u00e9ho p\u0159\u00edstupu<\/li>\n<li>Panely se mus\u00ed otev\u00edrat pro pln\u00fd p\u0159\u00edstup ke krabici<\/li>\n<li>Nelze pou\u017e\u00edt jako trvalou instalaci sk\u0159\u00edn\u011bk<\/li>\n<\/ul>\n<h3>Mo\u017enost 3: Mont\u00e1\u017e do sklepa nebo podkrov\u00ed<\/h3>\n<p><strong>Nejlep\u0161\u00ed pro:<\/strong> Novostavby a v\u011bt\u0161\u00ed rekonstrukce<\/p>\n<p><strong>Po\u017eadavky k\u00f3du:<\/strong><\/p>\n<ul>\n<li>Dostate\u010dn\u00fd prostor nad hlavou (minim\u00e1ln\u011b 1,8 metru, pokud je to mo\u017en\u00e9)<\/li>\n<li>Bezpe\u010dn\u00e1 p\u0159\u00edstupov\u00e1 cesta<\/li>\n<li>Spr\u00e1vn\u00e9 osv\u011btlen\u00ed pro kontrolu<\/li>\n<li>Ochrana p\u0159ed fyzick\u00fdm po\u0161kozen\u00edm<\/li>\n<li>Vhodn\u00e9 environment\u00e1ln\u00ed hodnocen\u00ed<\/li>\n<\/ul>\n<h2>Podrobn\u00fd n\u00e1vod: Jak vytvo\u0159it skryt\u00e9 rozvodn\u00e9 krabice v souladu s p\u0159edpisy<\/h2>\n<h3>Krok 1: Najd\u011bte v\u0161echny skryt\u00e9 krabice<\/h3>\n<ol>\n<li>Vypn\u011bte nap\u00e1jen\u00ed hlavn\u00edm jisti\u010dem<\/li>\n<li>Pou\u017eijte detektor h\u0159ebc\u016f s elektrickou detekc\u00ed<\/li>\n<li>Zkontrolujte tepl\u00e1 m\u00edsta na st\u011bn\u00e1ch (mohou nazna\u010dovat skryt\u00e9 spoje)<\/li>\n<li>Sledov\u00e1n\u00ed tras vodi\u010d\u016f z panel\u016f a sv\u00edtidel<\/li>\n<li>Zdokumentujte m\u00edsta pomoc\u00ed fotografi\u00ed a rozm\u011br\u016f<\/li>\n<\/ol>\n<h3>Krok 2: Vytvo\u0159te spr\u00e1vn\u00fd p\u0159\u00edstup<\/h3>\n<ol>\n<li>P\u0159esn\u011b ozna\u010dte um\u00edst\u011bn\u00ed pol\u00ed\u010dek<\/li>\n<li>\u0158ezte s\u00e1drokarton, abyste krabici zcela odkryli<\/li>\n<li>Pokud chyb\u00ed, nainstalujte vhodnou rozvodnou krabici<\/li>\n<li>Zajist\u011bte spr\u00e1vn\u00e9 p\u0159ipojen\u00ed vodi\u010d\u016f a bezpe\u010dn\u00e9 spoje<\/li>\n<li>Ov\u011b\u0159te dostate\u010dn\u00fd voln\u00fd pracovn\u00ed prostor<\/li>\n<\/ol>\n<h3>Krok 3: Instalace \u0159e\u0161en\u00ed Access Solutions<\/h3>\n<ol>\n<li><strong>Mo\u017enost A:<\/strong> Nainstalujte odn\u00edmateln\u00fd p\u0159\u00edstupov\u00fd panel<\/li>\n<li><strong>Mo\u017enost B:<\/strong> P\u0159em\u00edst\u011bte krabici na p\u0159\u00edstupn\u00e9 m\u00edsto<\/li>\n<li><strong>Mo\u017enost C:<\/strong> Nahra\u010fte povrchovou instalac\u00ed<\/li>\n<li>Zajist\u011bte, aby v\u0161echna p\u0159ipojen\u00ed spl\u0148ovala aktu\u00e1ln\u00ed po\u017eadavky p\u0159edpis\u016f.<\/li>\n<li>Zkontrolujte elektrickou vodivost a spr\u00e1vn\u00e9 uzemn\u011bn\u00ed<\/li>\n<\/ol>\n<h3>Krok 4: Z\u00e1v\u011bre\u010dn\u00e1 kontrola a dokumentace<\/h3>\n<ol>\n<li>V p\u0159\u00edpad\u011b pot\u0159eby napl\u00e1nujte elektroinstalaci<\/li>\n<li>Aktualizace adres\u00e1\u0159e elektrick\u00fdch rozvad\u011b\u010d\u016f<\/li>\n<li>Fotografie fin\u00e1ln\u00ed instalace pro z\u00e1znamy<\/li>\n<li>Zajist\u011bte, aby v\u0161echny p\u0159\u00edstupov\u00e9 body byly jasn\u011b ozna\u010deny<\/li>\n<li>Poskytn\u011bte dokumentaci majiteli domu<\/li>\n<\/ol>\n<blockquote>\n<p><strong>\ud83d\udca1 Tip odborn\u00edka:<\/strong> P\u0159i p\u0159emis\u0165ov\u00e1n\u00ed rozvodn\u00fdch krabic v\u017edy pou\u017e\u00edvejte vodi\u010de vhodn\u00e9 velikosti a dodr\u017eujte spr\u00e1vn\u00e9 techniky spojov\u00e1n\u00ed. Nadm\u011brn\u011b velk\u00e9 krabice poskytuj\u00ed lep\u0161\u00ed p\u0159\u00edstupnost a mo\u017enosti budouc\u00edho roz\u0161\u00ed\u0159en\u00ed.<\/p>\n<\/blockquote>\n<h2>B\u011b\u017en\u00e9 poru\u0161en\u00ed p\u0159\u00edstupu k rozvodn\u00e9 sk\u0159\u00edni a \u0159e\u0161en\u00ed<\/h2>\n<h3>Poru\u0161en\u00ed 1: Krabice zakryt\u00e9 s\u00e1drokartonem<\/h3>\n<p><strong>Probl\u00e9m:<\/strong> \u00dapln\u00e9 skryt\u00ed za hotov\u00fdmi zdmi<br \/><strong>\u0158e\u0161en\u00ed:<\/strong> Vy\u0159\u00edzn\u011bte p\u0159\u00edstupov\u00fd otvor a nainstalujte odn\u00edmateln\u00fd panel<br \/><strong>Dopad na n\u00e1klady:<\/strong> Korekce $150-$300 na krabici<\/p>\n<h3>Poru\u0161en\u00ed 2: Nedostate\u010dn\u00fd pracovn\u00ed prostor<\/h3>\n<p><strong>Probl\u00e9m:<\/strong> M\u00e9n\u011b ne\u017e 76 cm voln\u00e9ho prostoru pro p\u0159\u00edstup<br \/><strong>\u0158e\u0161en\u00ed:<\/strong> P\u0159em\u00edst\u011bte krabici nebo odstra\u0148te p\u0159ek\u00e1\u017eky<br \/><strong>Odkaz na k\u00f3d:<\/strong> NEC 110.26<\/p>\n<h3>Poru\u0161en\u00ed 3: Neozna\u010den\u00e9 p\u0159\u00edstupov\u00e9 panely<\/h3>\n<p><strong>Probl\u00e9m:<\/strong> Skryt\u00e9 panely bez elektrick\u00e9 identifikace<br \/><strong>\u0158e\u0161en\u00ed:<\/strong> Nainstalujte spr\u00e1vn\u00e9 elektrick\u00e9 v\u00fdstra\u017en\u00e9 \u0161t\u00edtky<br \/><strong>Po\u017eadavek:<\/strong> Identifika\u010dn\u00ed normy NEC 110.22<\/p>\n<h3>Poru\u0161en\u00ed 4: P\u0159\u00edstup vy\u017eadovan\u00fd n\u00e1strojem<\/h3>\n<p><strong>Probl\u00e9m:<\/strong> Panely vy\u017eaduj\u00edc\u00ed \u0161roubov\u00e1ky nebo speci\u00e1ln\u00ed n\u00e1stroje<br \/><strong>\u0158e\u0161en\u00ed:<\/strong> Nainstalujte upev\u0148ovac\u00ed prvky s tah\u00e1n\u00edm prstem nebo \u010dtvrtot\u00e1\u010dkov\u00e9 upev\u0148ovac\u00ed prvky<br \/><strong>Norma:<\/strong> Rychl\u00fd p\u0159\u00edstup bez n\u00e1\u0159ad\u00ed<\/p>\n<h2>Bezpe\u010dnostn\u00ed aspekty a odborn\u00e1 doporu\u010den\u00ed<\/h2>\n<h3>Kritick\u00e9 bezpe\u010dnostn\u00ed body<\/h3>\n<p><strong>\u26a0\ufe0f Prevence po\u017e\u00e1rn\u00edho nebezpe\u010d\u00ed:<\/strong><\/p>\n<ul>\n<li>V\u0161echny spoje vodi\u010d\u016f mus\u00ed b\u00fdt provedeny uvnit\u0159 schv\u00e1len\u00fdch rozvodn\u00fdch krabic<\/li>\n<li>Spr\u00e1vn\u00e9 dimenzov\u00e1n\u00ed vodi\u010d\u016f zabra\u0148uje p\u0159eh\u0159\u00e1t\u00ed<\/li>\n<li>Ochrana proti zemn\u00edmu kde je to po\u017eadov\u00e1no podle k\u00f3du<\/li>\n<li>Pravideln\u00e9 kontroln\u00ed pl\u00e1ny pro star\u0161\u00ed instalace<\/li>\n<\/ul>\n<p><strong>\u26a0\ufe0f Prevence \u00farazu elektrick\u00fdm proudem:<\/strong><\/p>\n<ul>\n<li>P\u0159ed prac\u00ed na elektrick\u00fdch za\u0159\u00edzen\u00edch v\u017edy vypn\u011bte nap\u00e1jen\u00ed<\/li>\n<li>Test <a href=\"https:\/\/test.viox.com\/cs\/mcb\/\">obvody<\/a> s certifikovan\u00fdmi testery nap\u011bt\u00ed<\/li>\n<li>Udr\u017eujte \u0159\u00e1dnou kontinuitu uzemn\u011bn\u00ed<\/li>\n<li>Pou\u017e\u00edvejte vhodn\u00e9 osobn\u00ed ochrann\u00e9 prost\u0159edky<\/li>\n<\/ul>\n<h3>Kdy zavolat odborn\u00edka<\/h3>\n<p><strong>Pot\u0159ebujeme elektrik\u00e1\u0159e s licenc\u00ed:<\/strong><\/p>\n<ul>\n<li>P\u0159esun rozvodn\u00fdch krabic na nov\u00e1 m\u00edsta<\/li>\n<li>Modernizace elektrick\u00fdch rozvad\u011b\u010d\u016f nebo obvod\u016f<\/li>\n<li>Instalace nov\u00fdch odbo\u010dn\u00fdch obvod\u016f<\/li>\n<li>Pr\u00e1ce s obvody 240 volt\u016f<\/li>\n<li>Ve\u0161ker\u00e9 pr\u00e1ce vy\u017eaduj\u00edc\u00ed povolen\u00ed k elektroinstalaci<\/li>\n<\/ul>\n<p><strong>Profesion\u00e1ln\u00ed v\u00fdhody:<\/strong><\/p>\n<ul>\n<li>Z\u00e1ruka dodr\u017eov\u00e1n\u00ed p\u0159edpis\u016f<\/li>\n<li>Spr\u00e1vn\u00e9 z\u00edsk\u00e1n\u00ed povolen\u00ed<\/li>\n<li>Poji\u0161t\u011bn\u00ed odpov\u011bdnosti<\/li>\n<li>z\u00e1ruka na elektroinstala\u010dn\u00ed pr\u00e1ce<\/li>\n<li>Odborn\u00e9 bezpe\u010dnostn\u00ed protokoly<\/li>\n<\/ul>\n<h2>Anal\u00fdza n\u00e1klad\u016f: \u0158e\u0161en\u00ed pro p\u0159\u00edstup do rozvodn\u00fdch sk\u0159\u00edn\u00ed<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Typ \u0159e\u0161en\u00ed<\/th>\n<th>N\u00e1klady na materi\u00e1l<\/th>\n<th>N\u00e1klady na pr\u00e1ci<\/th>\n<th>Celkov\u00e1 investice<\/th>\n<th>\u010casov\u00e1 osa<\/th>\n<\/tr>\n<tr>\n<td><strong>Instalace p\u0159\u00edstupov\u00e9ho panelu<\/strong><\/td>\n<td>$25-$50<\/td>\n<td>$100-$200<\/td>\n<td>$125-$250<\/td>\n<td>1\u20132 hodiny<\/td>\n<\/tr>\n<tr>\n<td><strong>Konverze povrchov\u00e9 mont\u00e1\u017ee<\/strong><\/td>\n<td>$40-$80<\/td>\n<td>$150-$300<\/td>\n<td>$190-$380<\/td>\n<td>2\u20133 hodiny<\/td>\n<\/tr>\n<tr>\n<td><strong>P\u0159em\u00edst\u011bn\u00ed krabice<\/strong><\/td>\n<td>$60-$120<\/td>\n<td>$200-$400<\/td>\n<td>$260-$520<\/td>\n<td>3\u20134 hodiny<\/td>\n<\/tr>\n<tr>\n<td><strong>Instalace nov\u00e9ho obvodu<\/strong><\/td>\n<td>$150-$300<\/td>\n<td>$300-$600<\/td>\n<td>$450-$900<\/td>\n<td>4\u20136 hodin<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<blockquote>\n<p><strong>\ud83d\udca1 Tip na \u00fasporu n\u00e1klad\u016f:<\/strong> \u0158e\u0161te v\u00edce poruch rozvodn\u00fdch krabic b\u011bhem jednoho servisn\u00edho z\u00e1sahu, abyste sn\u00ed\u017eili n\u00e1klady na pr\u00e1ci. Mnoho elektrik\u00e1\u0159\u016f nab\u00edz\u00ed bal\u00ed\u010dkov\u00e9 ceny za opravy v\u00edce krabic.<\/p>\n<\/blockquote>\n<h2>Stru\u010dn\u00fd p\u0159ehled: Kontroln\u00ed seznam p\u0159\u00edstupu k rozvodn\u00e9 sk\u0159\u00edni<\/h2>\n<h3>Kontroln\u00ed seznam p\u0159ed instalac\u00ed<\/h3>\n<ul>\n<li>Ov\u011b\u0159te po\u017eadavky elektrotechnick\u00fdch p\u0159edpis\u016f<\/li>\n<li>Pl\u00e1nujte pouze bezbari\u00e9rov\u00e1 m\u00edsta<\/li>\n<li>Zajist\u011bte dostate\u010dn\u00e9 pracovn\u00ed prostory<\/li>\n<li>Vyberte vhodn\u00e9 velikosti krabic<\/li>\n<li>Potvr\u010fte spr\u00e1vn\u00e9 hodnocen\u00ed vliv\u016f na \u017eivotn\u00ed prost\u0159ed\u00ed<\/li>\n<\/ul>\n<h3>Ov\u011b\u0159en\u00ed po instalaci<\/h3>\n<ul>\n<li>V\u0161echny boxy snadno dostupn\u00e9<\/li>\n<li>Spr\u00e1vn\u011b nainstalovan\u00e9 kryc\u00ed desky<\/li>\n<li>Jasn\u00e9 identifika\u010dn\u00ed ozna\u010den\u00ed<\/li>\n<li>Ov\u011b\u0159en\u00ed shody s k\u00f3dem<\/li>\n<li>Napl\u00e1novan\u00e1 elektroinspekce<\/li>\n<\/ul>\n<h3>Harmonogram \u00fadr\u017eby<\/h3>\n<ul>\n<li>Ro\u010dn\u00ed vizu\u00e1ln\u00ed kontrola<\/li>\n<li>Zkontrolujte, zda nejsou uvoln\u011bn\u00e9 spoje<\/li>\n<li>Ov\u011b\u0159te zabezpe\u010den\u00ed kryc\u00ed desky<\/li>\n<li>Test <a href=\"https:\/\/test.viox.com\/cs\/understanding-ground-fault-protection\/\">GFCI<\/a> ochrana, kde je to relevantn\u00ed<\/li>\n<li>Aktualizace elektrotechnick\u00e9 dokumentace<\/li>\n<\/ul>\n<h2>\u010casto Kladen\u00e9 Ot\u00e1zky<\/h2>\n<h3>Mohu nainstalovat rozvodnou krabici za odn\u00edmateln\u00fd panel?<\/h3>\n<p>Ano, rozvodn\u00e9 krabice lze instalovat za odn\u00edmateln\u00e9 panely, pokud k demont\u00e1\u017ei panelu nen\u00ed nutn\u00e9 pou\u017e\u00edt n\u00e1\u0159ad\u00ed a je k n\u011bmu zaji\u0161t\u011bn \u00fapln\u00fd p\u0159\u00edstup. Panel mus\u00ed b\u00fdt jasn\u011b ozna\u010den jako p\u0159\u00edstupn\u00fd pro elektrick\u00e9 rozvody.<\/p>\n<h3>Co se stane, kdy\u017e oblo\u017e\u00edm s\u00e1drokarton rozvodnou krabici?<\/h3>\n<p>Zakr\u00fdv\u00e1n\u00ed rozvodn\u00fdch krabic s\u00e1drokartonem poru\u0161uje elektrotechnick\u00e9 p\u0159edpisy, p\u0159edstavuje nebezpe\u010d\u00ed po\u017e\u00e1ru a m\u016f\u017ee zru\u0161it platnost poji\u0161t\u011bn\u00ed domu. Mus\u00edte zajistit \u0159\u00e1dn\u00fd p\u0159\u00edstup nebo krabici p\u0159em\u00edstit na bezbari\u00e9rov\u00e9 m\u00edsto.<\/p>\n<h3>Jak\u00fd voln\u00fd prostor je pot\u0159eba kolem rozvodn\u00fdch krabic?<\/h3>\n<p>NEC vy\u017eaduje minim\u00e1ln\u00ed voln\u00fd prostor 76 cm (30 palc\u016f) p\u0159ed elektrick\u00fdm za\u0159\u00edzen\u00edm pro bezpe\u010dn\u00fd p\u0159\u00edstup a \u00fadr\u017ebu. Bo\u010dn\u00ed vzd\u00e1lenosti z\u00e1vis\u00ed na konkr\u00e9tn\u00edch po\u017eadavc\u00edch na instalaci.<\/p>\n<h3>Mohou b\u00fdt rozvodn\u00e9 krabice ve st\u011bn\u00e1ch mezi m\u00edstnostmi?<\/h3>\n<p>Rozvodn\u00e9 krabice lze instalovat do vnit\u0159n\u00edch st\u011bn, pokud z\u016fstanou p\u0159\u00edstupn\u00e9 alespo\u0148 z jedn\u00e9 strany. P\u0159\u00edstup z obou stran nen\u00ed nutn\u00fd, ale \u00fapln\u00e9 skryt\u00ed je zak\u00e1z\u00e1no.<\/p>\n<h3>Jak\u00fd je rozd\u00edl mezi rozvodn\u00fdmi krabicemi a z\u00e1suvkov\u00fdmi krabicemi?<\/h3>\n<p>Rozvodn\u00e9 krabice obsahuj\u00ed pouze spojky a p\u0159ipojen\u00ed vodi\u010d\u016f, zat\u00edmco z\u00e1suvkov\u00e9 krabice obsahuj\u00ed z\u00e1suvky, sp\u00edna\u010de nebo p\u0159\u00edslu\u0161enstv\u00ed. Oboj\u00ed mus\u00ed z\u016fstat p\u0159\u00edstupn\u00e9, ale z\u00e1suvkov\u00e9 krabice p\u0159irozen\u011b poskytuj\u00ed p\u0159\u00edstup prost\u0159ednictv\u00edm sv\u00fdch za\u0159\u00edzen\u00ed.<\/p>\n<h3>Pot\u0159ebuj\u00ed v\u0161echny spoje vodi\u010d\u016f rozvodn\u00e9 krabice?<\/h3>\n<p>Ano, v\u0161echny spoje vodi\u010d\u016f mus\u00ed b\u00fdt um\u00edst\u011bny ve schv\u00e1len\u00fdch elektrick\u00fdch krabic\u00edch. P\u0159\u00edm\u00e9 spoje ve st\u011bn\u00e1ch, na p\u016fd\u00e1ch nebo v jin\u00fdch skryt\u00fdch prostor\u00e1ch bez \u0159\u00e1dn\u00e9ho kryt\u00ed poru\u0161uj\u00ed elektrotechnick\u00e9 p\u0159edpisy.<\/p>\n<h3>Jak najdu skryt\u00e9 rozvodn\u00e9 krabice v m\u00e9m dom\u011b?<\/h3>\n<p>Pou\u017e\u00edvejte sledova\u010de elektrick\u00fdch obvod\u016f, termovizi nebo si najm\u011bte elektrik\u00e1\u0159e s profesion\u00e1ln\u00edm detek\u010dn\u00edm vybaven\u00edm. Zkontrolujte m\u00edsta, kde by se mohlo sb\u00edhat v\u00edce obvod\u016f, nap\u0159\u00edklad rohy m\u00edstnost\u00ed nebo stropn\u00ed sv\u00edtidla.<\/p>\n<h3>Mohu pou\u017e\u00edt sk\u0159\u00ed\u0148 jako p\u0159\u00edstup k rozvodn\u00fdm krabic\u00edm?<\/h3>\n<p>Odn\u00edmateln\u00e9 panely sk\u0159\u00edn\u011bk mohou poskytovat p\u0159\u00edstup k rozvodn\u00e9 krabici, ale trval\u00e9 instalace sk\u0159\u00edn\u011bk se na to nevztahuj\u00ed. P\u0159\u00edstup mus\u00ed b\u00fdt snadno odn\u00edmateln\u00fd bez n\u00e1\u0159ad\u00ed a jasn\u011b ozna\u010den\u00fd.<\/p>\n<h2>Doporu\u010den\u00ed odborn\u00edk\u016f a osv\u011bd\u010den\u00e9 postupy<\/h2>\n<h3>Profesion\u00e1ln\u00ed instala\u010dn\u00ed standardy<\/h3>\n<p><strong>Nejlep\u0161\u00ed postupy v oboru:<\/strong><\/p>\n<ol>\n<li><strong>Nadrozm\u011brn\u00e9 krabice<\/strong> zajistit lep\u0161\u00ed p\u0159\u00edstup a budouc\u00ed roz\u0161\u00ed\u0159en\u00ed<\/li>\n<li><strong>Konzistentn\u00ed syst\u00e9my ozna\u010dov\u00e1n\u00ed<\/strong> zlep\u0161it efektivitu \u00fadr\u017eby<\/li>\n<li><strong>Strategick\u00e9 um\u00edst\u011bn\u00ed<\/strong> zohled\u0148uje jak p\u0159\u00edstup, tak estetiku<\/li>\n<li><strong>Kvalitn\u00ed materi\u00e1ly<\/strong> zajistit dlouhodobou spolehlivost a bezpe\u010dnost<\/li>\n<li><strong>\u0158\u00e1dn\u00e1 dokumentace<\/strong> pom\u00e1h\u00e1 s budouc\u00edmi elektroinstala\u010dn\u00edmi pracemi<\/li>\n<\/ol>\n<h3>Strategie pro zaji\u0161t\u011bn\u00ed budoucnosti<\/h3>\n<p><strong>Chytr\u00e9 pl\u00e1nov\u00e1n\u00ed instalace:<\/strong><\/p>\n<ul>\n<li>Instalace dal\u0161\u00edch rozvodn\u00fdch krabic b\u011bhem v\u00fdstavby<\/li>\n<li>Pro budouc\u00ed obvody pou\u017eijte v\u011bt\u0161\u00ed krabice<\/li>\n<li>Napl\u00e1nujte bezbari\u00e9rov\u00e9 trasy pro elektroinstalace<\/li>\n<li>Zva\u017ete po\u017eadavky na zapojen\u00ed inteligentn\u00ed dom\u00e1cnosti<\/li>\n<li>Udr\u017eujte podrobn\u00e9 elektrick\u00e9 v\u00fdkresy<\/li>\n<\/ul>\n<blockquote>\n<p><strong>\ud83d\udca1 Tip odborn\u00edka:<\/strong> P\u0159ed uzav\u0159en\u00edm zd\u00ed v\u017edy vyfo\u0165te elektroinstalace. Tato dokumentace se uk\u00e1\u017ee jako neoceniteln\u00e1 pro budouc\u00ed \u00fapravy a \u0159e\u0161en\u00ed probl\u00e9m\u016f.<\/p>\n<\/blockquote>\n<h2>Z\u00e1v\u011br: Zaji\u0161t\u011bn\u00ed bezpe\u010dn\u00e9 instalace rozvodn\u00fdch krabic v souladu s p\u0159edpisy<\/h2>\n<p>Rozvodn\u00e9 krabice nesm\u00ed b\u00fdt nikdy skryty za s\u00e1drokartonem ani jin\u00fdmi trval\u00fdmi stavebn\u00edmi materi\u00e1ly. Po\u017eadavky NEC na p\u0159\u00edstupnost existuj\u00ed k ochran\u011b \u017eivot\u016f a majetku zaji\u0161t\u011bn\u00edm kontrolovatelnosti a provozuschopnosti elektrick\u00fdch p\u0159ipojen\u00ed. A\u0165 u\u017e se zab\u00fdv\u00e1te st\u00e1vaj\u00edc\u00edmi poru\u0161en\u00edmi nebo pl\u00e1nujete nov\u00e9 instalace, v\u017edy up\u0159ednost\u0148ujte bezpe\u010dnost a dodr\u017eov\u00e1n\u00ed p\u0159edpis\u016f.<\/p>\n<p>V p\u0159\u00edpad\u011b slo\u017eit\u00fdch elektroinstala\u010dn\u00edch prac\u00ed nebo ot\u00e1zek t\u00fdkaj\u00edc\u00edch se souladu s p\u0159edpisy se pora\u010fte s licencovan\u00fdm elektrik\u00e1\u0159em, kter\u00fd zajist\u00ed, aby va\u0161e instalace spl\u0148ovala v\u0161echny m\u00edstn\u00ed a n\u00e1rodn\u00ed elektrotechnick\u00e9 normy. Spr\u00e1vn\u00e1 dostupnost rozvodn\u00e9 krabice je investic\u00ed do bezpe\u010dnosti, hodnoty a spolehlivosti elektrick\u00e9ho syst\u00e9mu va\u0161eho domova.<\/p>\n<p><strong>Prove\u010fte akci:<\/strong> Pokud m\u00e1te podez\u0159en\u00ed na skryt\u00e9 rozvodn\u00e9 krabice ve va\u0161\u00ed dom\u00e1cnosti, napl\u00e1nujte si odbornou elektroinspekci, abyste zajistili shodu s p\u0159edpisy a bezpe\u010dnost. Ned\u011blejte kompromisy v oblasti elektrick\u00e9 bezpe\u010dnosti \u2013 rizika jsou prost\u011b p\u0159\u00edli\u0161 velk\u00e1.<\/p>\n<h2>Souvisej\u00edc\u00ed<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/cs\/complete-guide-to-circuit-breaker-symbols\/\">Kompletn\u00ed pr\u016fvodce symboly jisti\u010d\u016f<\/a><\/p>\n<p><a href=\"https:\/\/test.viox.com\/cs\/terminal-box-vs-junction-box\/\">Svorkovnice vs. rozvodn\u00e1 sk\u0159\u00ed\u0148<\/a><\/p>\n<p><a href=\"https:\/\/test.viox.com\/cs\/difference-between-a-combiner-box-and-a-junction-box\/\">Rozd\u00edl mezi slu\u010dovac\u00ed krabic\u00ed a rozvodnou krabic\u00ed<\/a><\/p>\n<p><a href=\"https:\/\/test.viox.com\/cs\/understanding-electrical-junction-box-types\/\">Porozum\u011bn\u00ed typ\u016fm elektrick\u00fdch rozvodn\u00fdch sk\u0159\u00edn\u00ed<\/a><\/p>\n<\/div>\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Direct Answer: No, junction boxes cannot be completely hidden behind drywall. According to the National Electrical Code (NEC), all junction boxes must remain accessible without removing any part of the building structure or finish materials. This critical safety requirement prevents electrical hazards and ensures proper maintenance access. Understanding junction box accessibility requirements is essential for [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":18586,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-18585","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts\/18585","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/comments?post=18585"}],"version-history":[{"count":0,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts\/18585\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media\/18586"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media?parent=18585"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/categories?post=18585"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/tags?post=18585"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}