{"id":13269,"date":"2025-01-11T16:56:41","date_gmt":"2025-01-11T08:56:41","guid":{"rendered":"https:\/\/viox.com\/?p=13269"},"modified":"2025-01-11T17:14:43","modified_gmt":"2025-01-11T09:14:43","slug":"understanding-electrical-wiring-color-codes","status":"publish","type":"post","link":"https:\/\/test.viox.com\/cs\/understanding-electrical-wiring-color-codes\/","title":{"rendered":"Porozum\u011bn\u00ed barevn\u00fdm k\u00f3d\u016fm elektrick\u00fdch rozvod\u016f"},"content":{"rendered":"<div class=\"product-intro\">\n<p>Barevn\u00e9 k\u00f3dy elektroinstalace jsou standardizovan\u00e9 syst\u00e9my pou\u017e\u00edvan\u00e9 po cel\u00e9m sv\u011bt\u011b k identifikaci funkce a nap\u011bt\u00ed r\u016fzn\u00fdch vodi\u010d\u016f v elektrick\u00fdch instalac\u00edch, kter\u00e9 zaji\u0161\u0165uj\u00ed bezpe\u010dnost a efektivitu elektroinstala\u010dn\u00edch prac\u00ed. Tyto k\u00f3dy se li\u0161\u00ed podle regionu a pou\u017eit\u00ed, p\u0159i\u010dem\u017e N\u00e1rodn\u00ed elektrotechnick\u00e9 p\u0159edpisy (NEC) a Mezin\u00e1rodn\u00ed elektrotechnick\u00e1 komise (IEC) poskytuj\u00ed \u0161iroce uzn\u00e1van\u00e9 normy pro obytn\u00e9, komer\u010dn\u00ed a pr\u016fmyslov\u00e9 prost\u0159ed\u00ed.<\/p>\n<h2>Elektroinstala\u010dn\u00ed normy NEC a IEC<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-13270 size-full\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/01\/NEC-and-IEC-Wiring-Standards-visual-selection-e1736586845311.webp\" alt=\"NEC and IEC Wiring Standards - visual selection\" width=\"799\" height=\"600\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/01\/NEC-and-IEC-Wiring-Standards-visual-selection-e1736586845311.webp 799w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/01\/NEC-and-IEC-Wiring-Standards-visual-selection-e1736586845311-300x225.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/01\/NEC-and-IEC-Wiring-Standards-visual-selection-e1736586845311-768x577.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/01\/NEC-and-IEC-Wiring-Standards-visual-selection-e1736586845311-16x12.webp 16w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/01\/NEC-and-IEC-Wiring-Standards-visual-selection-e1736586845311-600x451.webp 600w\" sizes=\"(max-width: 799px) 100vw, 799px\" \/><\/p>\n<p>Normy NEC (National Electrical Code) a IEC (International Electrotechnical Commission) tvo\u0159\u00ed p\u00e1te\u0159 barevn\u00fdch k\u00f3d\u016f elektrick\u00fdch rozvod\u016f na cel\u00e9m sv\u011bt\u011b, p\u0159i\u010dem\u017e ka\u017ed\u00e1 z nich m\u00e1 odli\u0161n\u00fd p\u0159\u00edstup k identifikaci vodi\u010d\u016f.<\/p>\n<p>Normy NEC, kter\u00e9 se pou\u017e\u00edvaj\u00ed p\u0159edev\u0161\u00edm ve Spojen\u00fdch st\u00e1tech, stanovuj\u00ed jednoduch\u00fd syst\u00e9m barevn\u00e9ho zna\u010den\u00ed pro bytov\u00e9 a komer\u010dn\u00ed rozvody. V jednof\u00e1zov\u00fdch syst\u00e9mech 120\/240 V se pro hork\u00e9 vodi\u010de pou\u017e\u00edvaj\u00ed \u010dern\u00e9 a \u010derven\u00e9 vodi\u010de, pro neutr\u00e1ln\u00ed vodi\u010de b\u00edl\u00e9 a pro uzemn\u011bn\u00ed zelen\u00e9, zelen\u00e9 se \u017elut\u00fdm pruhem nebo hol\u00e9 m\u011bd\u011bn\u00e9 vodi\u010de. U t\u0159\u00edf\u00e1zov\u00fdch syst\u00e9m\u016f 120\/208 V ozna\u010duje NEC \u010dernou, \u010dervenou a modrou barvu pro t\u0159i f\u00e1ze, p\u0159i\u010dem\u017e b\u00edl\u00e1 barva z\u016fst\u00e1v\u00e1 zachov\u00e1na pro nulov\u00fd vodi\u010d a zelen\u00e1 pro zem.<\/p>\n<p>Normy IEC, p\u0159ijat\u00e9 v mnoha zem\u00edch sv\u011bta, nab\u00edzej\u00ed odli\u0161n\u00e9 barevn\u00e9 sch\u00e9ma. V jednof\u00e1zov\u00fdch syst\u00e9mech se pro vodi\u010d veden\u00ed pou\u017e\u00edv\u00e1 hn\u011bd\u00e1 barva, pro nulov\u00fd vodi\u010d modr\u00e1 a pro zem zeleno\u017elut\u00e1. V t\u0159\u00edf\u00e1zov\u00fdch syst\u00e9mech se podle sm\u011brnic IEC pou\u017e\u00edv\u00e1 hn\u011bd\u00e1, \u010dern\u00e1 a \u0161ed\u00e1 barva pro t\u0159i f\u00e1ze, modr\u00e1 pro nulov\u00fd vodi\u010d a zeleno\u017elut\u00e1 pro zem.<\/p>\n<p>Hlavn\u00ed rozd\u00edl mezi normami NEC a IEC spo\u010d\u00edv\u00e1 v p\u0159\u00edstupu k nulov\u00fdm vodi\u010d\u016fm. Zat\u00edmco NEC d\u016fsledn\u011b pou\u017e\u00edv\u00e1 b\u00edlou barvu, IEC pou\u017e\u00edv\u00e1 modrou, co\u017e m\u016f\u017ee b\u00fdt pro mezin\u00e1rodn\u00ed projekty z\u00e1sadn\u00ed rozd\u00edl. Krom\u011b toho jsou normy IEC celosv\u011btov\u011b roz\u0161\u00ed\u0159en\u011bj\u0161\u00ed, co\u017e je pro odborn\u00edky pracuj\u00edc\u00ed na mezin\u00e1rodn\u00edch elektrick\u00fdch instalac\u00edch z\u00e1sadn\u00ed.<\/p>\n<p>Ob\u011b normy zd\u016fraz\u0148uj\u00ed v\u00fdznam spr\u00e1vn\u00e9 identifikace vodi\u010d\u016f pro bezpe\u010dnost a \u00fa\u010dinnost. Je v\u0161ak d\u016fle\u017eit\u00e9 si uv\u011bdomit, \u017ee samotn\u00e9 barevn\u00e9 k\u00f3dy by nikdy nem\u011bly b\u00fdt jedinou metodou identifikace vodi\u010d\u016f. V\u017edy je nutn\u00e9 prov\u00e9st \u0159\u00e1dn\u00e9 testov\u00e1n\u00ed a ov\u011b\u0159en\u00ed, a to bez ohledu na to, jakou normou se \u0159\u00edd\u00ed.<\/p>\n<p>Znalost t\u011bchto norem je pro elektrik\u00e1\u0159e a in\u017een\u00fdry pracuj\u00edc\u00ed v zahrani\u010d\u00ed z\u00e1sadn\u00ed. Nap\u0159\u00edklad odborn\u00edk vy\u0161kolen\u00fd v norm\u00e1ch NEC bude muset p\u0159izp\u016fsobit sv\u00e9 postupy p\u0159i pr\u00e1ci v zemi, kter\u00e1 se \u0159\u00edd\u00ed sm\u011brnicemi IEC, aby byla zaji\u0161t\u011bna shoda a bezpe\u010dnost. Tato p\u0159izp\u016fsobivost je d\u016fle\u017eit\u00e1 zejm\u00e9na v pr\u016fmyslov\u00e9m prost\u0159ed\u00ed, kde m\u016f\u017ee nespr\u00e1vn\u00e1 identifikace vodi\u010d\u016f v\u00e9st k v\u00e1\u017en\u00e9mu ohro\u017een\u00ed bezpe\u010dnosti a po\u0161kozen\u00ed za\u0159\u00edzen\u00ed.<\/p>\n<p><img decoding=\"async\" class=\"size-full wp-image-13271 aligncenter\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/01\/NEC-and-IEC-Wiring-Standards.webp\" alt=\"NEC and IEC Wiring Standards\" width=\"800\" height=\"443\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/01\/NEC-and-IEC-Wiring-Standards.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/01\/NEC-and-IEC-Wiring-Standards-300x166.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/01\/NEC-and-IEC-Wiring-Standards-768x425.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/01\/NEC-and-IEC-Wiring-Standards-18x10.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/01\/NEC-and-IEC-Wiring-Standards-600x332.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h2>Elektroinstala\u010dn\u00ed k\u00f3dy specifick\u00e9 pro danou zemi<\/h2>\n<p>Barevn\u00e9 k\u00f3dy elektroinstalace se v jednotliv\u00fdch zem\u00edch v\u00fdrazn\u011b li\u0161\u00ed, co\u017e odr\u00e1\u017e\u00ed region\u00e1ln\u00ed standardy a historick\u00e9 zvyklosti. V Japonsku se v jednof\u00e1zov\u00fdch syst\u00e9mech pou\u017e\u00edv\u00e1 \u010dern\u00e1 nebo \u010derven\u00e1 barva pro vodi\u010de pod nap\u011bt\u00edm, b\u00edl\u00e1 pro nulov\u00fd vodi\u010d a zelen\u00e1 pro uzemn\u011bn\u00ed. Sou\u010dasn\u00e9 \u010d\u00ednsk\u00e9 normy ozna\u010duj\u00ed \u017elutou, zelenou a \u010dervenou barvu pro t\u0159\u00edf\u00e1zov\u00e9 veden\u00ed, modrou nebo \u010dernou barvu pro nulov\u00fd vodi\u010d a zeleno\u017elutou barvu pro zem. Velk\u00e1 Brit\u00e1nie, kter\u00e1 p\u0159e\u0161la ze star\u00e9ho syst\u00e9mu, se nyn\u00ed \u0159\u00edd\u00ed normami IEC s hn\u011bdou barvou pro \u017eiv\u00fd vodi\u010d, modrou pro nulov\u00fd vodi\u010d a zeleno\u017elutou pro zem. Austr\u00e1lie se rovn\u011b\u017e \u0159\u00edd\u00ed normami IEC, \u010d\u00edm\u017e je zaji\u0161t\u011bn soulad s mnoha evropsk\u00fdmi zem\u011bmi. Tyto p\u0159edpisy specifick\u00e9 pro jednotliv\u00e9 zem\u011b zd\u016fraz\u0148uj\u00ed, \u017ee p\u0159i pr\u00e1ci na mezin\u00e1rodn\u00edch elektrotechnick\u00fdch projektech je d\u016fle\u017eit\u00e9 sezn\u00e1mit se s m\u00edstn\u00edmi normami, aby byla zachov\u00e1na bezpe\u010dnost a shoda s p\u0159edpisy.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-13274\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/01\/Electrical-Wiring-Color-Codes-NEC-IEC-Single-Phase-Three-Phase-AC-1024x402-1.webp\" alt=\"Electrical-Wiring-Color-Codes-NEC-IEC-Single-Phase-Three-Phase-AC-1024x402\" width=\"1024\" height=\"402\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/01\/Electrical-Wiring-Color-Codes-NEC-IEC-Single-Phase-Three-Phase-AC-1024x402-1.webp 1024w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/01\/Electrical-Wiring-Color-Codes-NEC-IEC-Single-Phase-Three-Phase-AC-1024x402-1-300x118.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/01\/Electrical-Wiring-Color-Codes-NEC-IEC-Single-Phase-Three-Phase-AC-1024x402-1-768x302.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/01\/Electrical-Wiring-Color-Codes-NEC-IEC-Single-Phase-Three-Phase-AC-1024x402-1-18x7.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/01\/Electrical-Wiring-Color-Codes-NEC-IEC-Single-Phase-Three-Phase-AC-1024x402-1-600x236.webp 600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<h2>Protokoly o bezpe\u010dnosti elektrick\u00fdch rozvod\u016f<\/h2>\n<p>Bezpe\u010dnostn\u00ed protokoly v elektroinstalaci jsou nejd\u016fle\u017eit\u011bj\u0161\u00ed bez ohledu na syst\u00e9m barevn\u00e9ho zna\u010den\u00ed. V\u0161echny elektrick\u00e9 vodi\u010de by m\u011bly b\u00fdt pova\u017eov\u00e1ny za potenci\u00e1ln\u011b nebezpe\u010dn\u00e9 a barvy vodi\u010d\u016f by nikdy nem\u011bly b\u00fdt jedinou metodou identifikace. K ov\u011b\u0159en\u00ed zapojen\u00ed je v\u017edy nutn\u00e9 pou\u017e\u00edt vhodn\u00e9 testovac\u00ed za\u0159\u00edzen\u00ed a ve\u0161ker\u00e9 odchylky od standardn\u00edch barevn\u00fdch k\u00f3d\u016f by m\u011bly b\u00fdt d\u016fkladn\u011b zdokumentov\u00e1ny. Tato z\u00e1sadn\u00ed bezpe\u010dnostn\u00ed opat\u0159en\u00ed pom\u00e1haj\u00ed p\u0159edch\u00e1zet \u00faraz\u016fm elektrick\u00fdm proudem, zkrat\u016fm a dal\u0161\u00edm nebezpe\u010d\u00edm spojen\u00fdm s nespr\u00e1vnou identifikac\u00ed vodi\u010d\u016f. V pr\u016fmyslov\u00e9m prost\u0159ed\u00ed nav\u00edc t\u0159\u00edf\u00e1zov\u00e9 syst\u00e9my vy\u017eaduj\u00ed p\u0159\u00edsn\u00e9 dodr\u017eov\u00e1n\u00ed barevn\u00e9ho zna\u010den\u00ed pro \u00fa\u010dely bezpe\u010dnosti a \u00fadr\u017eby, p\u0159i\u010dem\u017e syst\u00e9my s vy\u0161\u0161\u00edm nap\u011bt\u00edm vy\u017eaduj\u00ed dal\u0161\u00ed dokumentaci a jasn\u00e9 ozna\u010den\u00ed informac\u00ed o obvodech a m\u00edstech odpojen\u00ed.<\/p>\n<h2>Pr\u016fmyslov\u00e9 aplikace elektroinstala\u010dn\u00edch k\u00f3d\u016f<\/h2>\n<p>V pr\u016fmyslov\u00e9m prost\u0159ed\u00ed hraj\u00ed barevn\u00e9 k\u00f3dy kabel\u00e1\u017ee z\u00e1sadn\u00ed roli p\u0159i zaji\u0161\u0165ov\u00e1n\u00ed bezpe\u010dnosti a efektivity. Pro vysokonap\u011b\u0165ov\u00e9 syst\u00e9my (277\/480 V) ur\u010duje NEC hn\u011bdou, oran\u017eovou a \u017elutou barvu pro t\u0159i f\u00e1ze, \u0161edou pro nulov\u00fd vodi\u010d a zelenou nebo holou pro zem. Tyto barevn\u00e9 k\u00f3dy jsou z\u00e1sadn\u00ed pro elektrik\u00e1\u0159e, aby v\u011bd\u011bli, jak spr\u00e1vn\u011b dimenzovat vodi\u010de a vypo\u010d\u00edtat \u00fabytky nap\u011bt\u00ed. Pr\u016fmyslov\u00e9 aplikace \u010dasto vy\u017eaduj\u00ed dal\u0161\u00ed dokumentaci, v\u010detn\u011b informac\u00ed o obvodech a jasn\u00e9ho ozna\u010den\u00ed m\u00edst odpojen\u00ed, aby se zv\u00fd\u0161ila bezpe\u010dnost p\u0159i \u00fadr\u017eb\u011b a \u0159e\u0161en\u00ed probl\u00e9m\u016f. T\u0159\u00edf\u00e1zov\u00e9 syst\u00e9my, b\u011b\u017en\u00e9 v pr\u016fmyslov\u00e9m prost\u0159ed\u00ed, mus\u00ed dodr\u017eovat p\u0159\u00edsn\u00e9 normy barevn\u00e9ho zna\u010den\u00ed, aby se zabr\u00e1nilo potenci\u00e1ln\u011b nebezpe\u010dn\u00fdm z\u00e1m\u011bn\u00e1m a usnadnila se rychl\u00e1 identifikace funkc\u00ed vodi\u010d\u016f.<\/p>\n<h2>V\u00fdhody v oblasti bezpe\u010dnosti a dodr\u017eov\u00e1n\u00ed p\u0159edpis\u016f<\/h2>\n<p>Dodr\u017eov\u00e1n\u00ed barevn\u00fdch k\u00f3d\u016f elektrick\u00fdch vodi\u010d\u016f m\u00e1 z\u00e1sadn\u00ed v\u00fdznam pro bezpe\u010dnost, efektivitu a dodr\u017eov\u00e1n\u00ed p\u0159edpis\u016f v elektrick\u00fdch instalac\u00edch. Spr\u00e1vn\u00e9 barevn\u00e9 zna\u010den\u00ed umo\u017e\u0148uje rychlou identifikaci funkc\u00ed vodi\u010d\u016f a sni\u017euje riziko chyb, kter\u00e9 by mohly v\u00e9st k \u00farazu elektrick\u00fdm proudem, po\u017e\u00e1ru nebo po\u0161kozen\u00ed za\u0159\u00edzen\u00ed. Usnad\u0148uje tak\u00e9 rychlej\u0161\u00ed \u0159e\u0161en\u00ed probl\u00e9m\u016f a \u00fadr\u017ebu, \u010d\u00edm\u017e \u0161et\u0159\u00ed \u010das a zdroje p\u0159i oprav\u00e1ch nebo modernizaci syst\u00e9mu.<\/p>\n<ul>\n<li>Zvy\u0161uje bezpe\u010dnost t\u00edm, \u017ee zabra\u0148uje chybn\u00fdm zapojen\u00edm a potenci\u00e1ln\u00edm nebezpe\u010d\u00edm.<\/li>\n<li>Zvy\u0161uje efektivitu instalace, \u00fadr\u017eby a \u0159e\u0161en\u00ed probl\u00e9m\u016f.<\/li>\n<li>Zaji\u0161\u0165uje shodu s m\u00edstn\u00edmi a mezin\u00e1rodn\u00edmi elektrotechnick\u00fdmi normami.<\/li>\n<li>Usnad\u0148uje jasnou komunikaci mezi elektrik\u00e1\u0159i a techniky.<\/li>\n<li>Podpora interoperability v rozs\u00e1hl\u00fdch nebo dlouhodob\u00fdch projektech<\/li>\n<\/ul>\n<p>Standardizovan\u00e9 barevn\u00e9 k\u00f3dy hraj\u00ed d\u016fle\u017eitou roli tak\u00e9 v nouzov\u00fdch situac\u00edch, proto\u017ee umo\u017e\u0148uj\u00ed prvn\u00edm z\u00e1sahov\u00fdm jednotk\u00e1m rychle vyhodnotit elektrick\u00e9 nebezpe\u010d\u00ed a reagovat na n\u011bj. S t\u00edm, jak se elektrick\u00e9 syst\u00e9my st\u00e1vaj\u00ed slo\u017eit\u011bj\u0161\u00edmi, je p\u0159\u00edsn\u00e9 dodr\u017eov\u00e1n\u00ed standard\u016f barevn\u00e9ho zna\u010den\u00ed st\u00e1le d\u016fle\u017eit\u011bj\u0161\u00ed pro zachov\u00e1n\u00ed integrity a bezpe\u010dnosti modern\u00ed elektrick\u00e9 infrastruktury.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Electrical wiring color codes are standardized systems used globally to identify the function and voltage of different wires in electrical installations, ensuring safety and efficiency in electrical work. These codes vary by region and application, with the National Electrical Code (NEC) and International Electrotechnical Commission (IEC) providing widely recognized standards for residential, commercial, and industrial [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":13273,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-13269","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts\/13269","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/comments?post=13269"}],"version-history":[{"count":0,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/posts\/13269\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media\/13273"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/media?parent=13269"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/categories?post=13269"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/cs\/wp-json\/wp\/v2\/tags?post=13269"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}